Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 316

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Performance evaluation for rapid detection of pan-cancer microsatellite instability with MANTIS

Open access
Kautto, Esko A., Bonneville, Russell, Miya, Jharna, Yu, Lianbo, Krook, Melanie A., Reeser, Julie W., Roychowdhury, Sameek · 2017 · Oncotarget

Abstract

// Esko A. Kautto 1 , Russell Bonneville 1 , Jharna Miya 1 , Lianbo Yu 2 , Melanie A. Krook 1 , Julie W. Reeser 1 and Sameek Roychowdhury 1,3 1 Comprehensive Cancer Center, The Ohio State University, Columbus, OH, USA 2 Department of Biomedical Informatics, The Ohio State University, Columbus, OH, USA 3 Division of Medical Oncology, Department of Internal Medicine, The Ohio State University, Columbus, OH, USA Correspondence to: Sameek Roychowdhury, email: // Keywords : microsatellite instability, computational biology, next-generation sequencing Received : November 24, 2016 Accepted : December 02, 2016 Published : December 12, 2016 Abstract In current clinical practice, microsatellite instability (MSI) and mismatch repair deficiency detection is performed with MSI-PCR and immunohistochemistry. Recent research has produced several computational tools for MSI detection with next-generation sequencing (NGS) data; however a comprehensive analysis of computational methods has not yet been performed. In this study, we introduce a new MSI detection tool, MANTIS, and demonstrate its favorable performance compared to the previously published tools mSINGS and MSISensor. We evaluated 458 normal-tumor sample pairs across six cancer subtypes, testing classification performance on variable numbers of target loci ranging from 10 to 2539. All three computational methods were found to be accurate, with MANTIS exhibiting the highest accuracy with 98.91% of samples from all six diseases classified correctly. MANTIS displayed superior performance among the three tools, having the highest overall sensitivity (MANTIS 97.18%, MSISensor 96.48%, mSINGS 76.06%) and specificity (MANTIS 99.68%, mSINGS 99.68%, MSISensor 98.73%) across six cancer types, even with loci panels of varying size. Additionally, MANTIS also had the lowest resource consumption (<1% of the space and <7% of the memory required by mSINGS) and fastest running times (49.6% and 8.7% of the running times of MSISensor and mSINGS, respectively). This study highlights the potential utility of MANTIS in classifying samples by MSI-status, allowing its incorporation into existing NGS pipelines.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.18632/oncotarget.13918

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

See all 316

Metadata

Authors
Kautto, E. A., Bonneville, R., Miya, J., Yu, L., Krook, M. A., Reeser, J. W., & Roychowdhury, S.
Venue
Oncotarget
Published
2016-12-12
Volume
8
Issue
5
Pages
7452-7463
ISSN
1949-2553 (ISSN-L)
OpenAlex
W2567051070
Cited by
316
References
36
FWCI
14.33
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance evaluation for rapid detection of pan-cancer microsatellite instability with MANTIS. https://app.cochat.ai/papers/10.18632/oncotarget.13918
The paper
Kautto, E. A., Bonneville, R., Miya, J., Yu, L., Krook, M. A., Reeser, J. W., & Roychowdhury, S. (2017). Performance evaluation for rapid detection of pan-cancer microsatellite instability with MANTIS. Oncotarget. https://doi.org/10.18632/oncotarget.13918

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.