Measurement of Activity in Older Adults: Reliability and Validity of the Step Activity Monitor
The DOI matches its Crossref record.
Abstract
The purpose of this study was to test the reliability and validity of the Step Activity Monitor (SAM) when used with older adults. A total of 30 subjects with a mean age of 86 ± 6.1 participated in the study. Sixty one-minute walks were measured with the SAM, and two observers visually counted steps. Four participants wore the SAM for 6 to 48 hours and maintained activity diaries. The intraclass correlation for the SAM recordings was R = .84. There was an overall step counting accuracy of 96%. The diaries supported the SAM data for those who wore the SAM for extended periods. The SAM is an easy to use, comfortable, valid, and reliable measure of activity in older adults and particularly may be useful to triangulate measurement of activity in these individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Body-Weight–Supported Treadmill Rehabilitation after Stroke
Duncan, P. W., Sullivan, K. J., Behrman, A. L., Azen, S. P., Wu, S. S., Nadeau, S. E., Dobkin, B. H., Rose, D. K., Tilson, J. K., Cen, S., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1010790 · Cited by 652
Functional Impact of 10 Days of Bed Rest in Healthy Older Adults
Kortebein, P., Symons, T. B., Ferrando, A., Paddon-Jones, D., Ronsen, O., Protas, E., Conger, S., Lombeida, J., Wolfe, R., & Evans, W. J. (2008) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/63.10.1076 · Cited by 550
Reduced Ambulatory Activity After Stroke: The Role of Balance, Gait, and Cardiovascular Fitness
Michael, K. M., Allen, J. K., & Macko, R. F. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.12.026 · Cited by 505
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Barriers to Exercise in People With Parkinson Disease
Ellis, T., Boudreau, J. K., DeAngelis, T. R., Brown, L. E., Cavanaugh, J. T., Earhart, G. M., Ford, M. P., Foreman, K. B., & Dibble, L. E. (2013) · Physical Therapy · doi:10.2522/ptj.20120279 · Cited by 340
How humans walk: Bout duration, steps per bout, and rest duration
Orendurff, M. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.11.0197 · Cited by 306
“SAMs have step count accuracy of better than 98 percent [39–41].”
BackgroundMiles, L. (2007) · Nutrition Bulletin · doi:10.1111/j.1467-3010.2007.00668.x · Cited by 299
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
Kowalski, K., Rhodes, R., Naylor, P.-J., Tuokko, H., & MacDonald, S. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-148 · Cited by 212
“99) for steps counted by direct observation and pedometry [56,63] and steps counted by direct observation and accelerometry [64].”
BackgroundMethodInfluentialUsing Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
The LEAPS Investigative Team, Duncan, P. W., Sullivan, K. J., Behrman, A. L., Azen, S. P., Wu, S. S., Nadeau, S. E., Dobkin, B. H., Rose, D. K., & Tilson, J. K. (2007) · BMC Neurology · doi:10.1186/1471-2377-7-39 · Cited by 205
“The device has a 99% accuracy for recording steps with a variety of gait patterns [27-29].”
Locomotor Training Progression and Outcomes After Incomplete Spinal Cord Injury
Behrman, A. L., Lawless-Dixon, A. R., Davis, S. B., Bowden, M. G., Nair, P., Phadke, C., Hannold, E. M., Plummer, P., & Harkema, S. J. (2005) · Physical Therapy · doi:10.1093/ptj/85.12.1356 · Cited by 190
Low‐intensity daily walking activity is associated with hippocampal volume in older adults
Varma, V. R., Chuang, Y., Harris, G. C., Tan, E. J., & Carlson, M. C. (2015) · Hippocampus · doi:10.1002/hipo.22397 · Cited by 188
“The SAM has been validated across a range of community-dwelling older adult populations with varying levels of function using self-report and objective measures (e.g., Hippocampus hand-tallied step counts and accelerometers) (Resnick et al., 2001; Cavanaugh et al., 2007; Storti et al., 2008).”
BackgroundHaeuber, E., Shaughnessy, M., Forrester, L. W., Coleman, K. L., & Macko, R. F. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.035 · Cited by 182
LeMaster, J. W., Mueller, M. J., Reiber, G. E., Mehr, D. R., Madsen, R. W., & Conn, V. S. (2008) · Physical Therapy · doi:10.2522/ptj.20080019 · Cited by 179
Brandes, M., Ringling, M., Winter, C., Hillmann, A., & Rosenbaum, D. (2011) · Arthritis Care & Research · doi:10.1002/acr.20384 · Cited by 172
Factors Associated With Exercise Behavior in People With Parkinson Disease
Ellis, T., Cavanaugh, J. T., Earhart, G. M., Ford, M. P., Foreman, K. B., Fredman, L., Boudreau, J. K., & Dibble, L. E. (2011) · Physical Therapy · doi:10.2522/ptj.20100390 · Cited by 171
Wearable systems for monitoring mobility-related activities in older people: a systematic review
de Bruin, E. D., Hartmann, A., Uebelhart, D., Murer, K., & Zijlstra, W. (2008) · Clinical Rehabilitation · doi:10.1177/0269215508090675 · Cited by 170
White, D. K., Tudor‐Locke, C., Zhang, Y., Fielding, R., LaValley, M., Felson, D. T., Gross, K. D., Nevitt, M. C., Lewis, C. E., Torner, J., et al. (2014) · Arthritis Care & Research · doi:10.1002/acr.22362 · Cited by 165
“frequency in older adults (20) and high convergent validity”
BackgroundValidity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities
Bergman, R. J., Bassett, D. R., & Klein, D. A. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s166 · Cited by 62
White, D. K., Keysor, J. J., Neogi, T., Felson, D. T., LaValley, M., Gross, K. D., Niu, J., Nevitt, M., Lewis, C. E., Torner, J., et al. (2012) · Arthritis Care & Research · doi:10.1002/acr.21694 · Cited by 52
“Short Form 36 scores among participants with OA (24).”
Background
Metadata
- Authors
- Resnick, B., Nahm, E.-S., Orwig, D., Zimmerman, S. S., & Magaziner, J.
- Venue
- Journal of Nursing Measurement
- Publisher
- Springer Publishing Company
- Published
- 2001-01
- Volume
- 9
- Issue
- 3
- Pages
- 275-290
- ISSN
- 1061-3749 (ISSN-L)
- 1945-7049
- OpenAlex
- W2309555446
- Cited by
- 105
- References
- 0
- FWCI
- 0.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.