Clinical application of indocyanine green-fluorescence imaging during hepatectomy
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
In hepatobiliary surgery, the fluorescence and bile excretion of indocyanine green (ICG) can be used for real-time visualization of biological structure. Fluorescence cholangiography is used to obtain fluorescence images of the bile ducts following intrabiliary injection of 0.025-0.5 mg/mL ICG or intravenous injection of 2.5 mg ICG. Recently, the latter technique has been used in laparoscopic/robotic cholecystectomy. Intraoperative fluorescence imaging can be used to identify subcapsular hepatic tumors. Primary and secondary hepatic malignancy can be identified by intraoperative fluorescence imaging using preoperative intravenous injection of ICG through biliary excretion disorders that exist in cancerous tissues of hepatocellular carcinoma (HCC) and in non-cancerous hepatic parenchyma around adenocarcinoma foci. Intraoperative fluorescence imaging may help detect tumors to be removed, especially during laparoscopic hepatectomy, in which visual inspection and palpation are limited, compared with open surgery. Fluorescence imaging can also be used to identify hepatic segments. Boundaries of hepatic segments can be visualized following injection of 0.25-2.5 mg/mL ICG into the portal veins or by intravenous injection of 2.5 mg ICG following closure of the proximal portal pedicle toward hepatic regions to be removed. These techniques enable identification of hepatic segments before hepatectomy and during parenchymal transection for anatomic resection. Advances in imaging systems will increase the use of fluorescence imaging as an intraoperative navigation tool that can enhance the safety and accuracy of open and laparoscopic/robotic hepatobiliary surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of the problem of biliary injury during laparoscopic cholecystectomy.
Berci, G., & Morgenstern, L. (1995) · PubMed · Cited by 1,634
INDOCYANINE GREEN: OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION*
Cherrick, G. R., Stein, S. W., Leevy, C. M., & Davidson, C. S. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104072 · Cited by 979 · cited 1×
“Although biliary excretion of ICG begins within minutes after intravenous injection (21), ICG should be administered at least 15 minutes before imaging to obtain better signal-to-background contrast.”
BackgroundReal‐time identification of liver cancers by using indocyanine green fluorescent imaging
Ishizawa, T., Fukushima, N., Shibahara, J., Masuda, K., Tamura, S., Aoki, T., Hasegawa, K., Beck, Y., Fukayama, M., & Kokudo, N. (2009) · Cancer · doi:10.1002/cncr.24291 · Cited by 852 · cited 4×
“The incidence of false-positives can be reduced by not administering ICG on the day before surgery, especially in patients with decreased liver function due to cirrhosis or preoperative chemotherapy (13).”
BackgroundInfluentialSelf-citationLight-absorbing properties, stability, and spectral stabilization of indocyanine green
Landsman, M. L., Kwant, G., Mook, G. A., & Zijlstra, W. G. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.4.575 · Cited by 834
An analysis of the problem of biliary injury during laparoscopic cholecystectomy.
Strasberg, S. M., Hertl, M., & Nj, S. (1995) · PubMed · Cited by 681
Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 677
Fluorescent cholangiography illuminating the biliary tree during laparoscopic cholecystectomy
Ishizawa, T., Bandai, Y., Ijichi, M., Kaneko, J., Hasegawa, K., & Kokudo, N. (2010) · British Journal of Surgery · doi:10.1002/bjs.7125 · Cited by 381
Self-citationKusano, M., Tajima, Y., Yamazaki, K., Kato, M., Watanabe, M., & Miwa, M. (2008) · Digestive Surgery · doi:10.1159/000121905 · Cited by 315 · cited 1×
“com HepatoBiliary Surg Nutr 2016;5(4):322-328 become widespread as an intraoperative navigation tool to detect lymphatic flow in the extremities (3); sentinel lymph nodes in patients with breast (4) and gastric (5) cancers; and blood flow during coronary artery bypass grafting (6) and clipping of cerebral artery aneur…”
BackgroundNear‐infrared fluorescence‐guided resection of colorectal liver metastases
van der Vorst, J. R., Schaafsma, B. E., Hutteman, M., Verbeek, F. P. R., Liefers, G., Hartgrink, H. H., Smit, V. T. H. B. M., Löwik, C. W. G. M., van de Velde, C. J. H., Frangioni, J. V., et al. (2013) · Cancer · doi:10.1002/cncr.28203 · Cited by 309
Aoki, T., Yasuda, D., Shimizu, Y., Odaira, M., Niiya, T., Kusano, T., Mitamura, K., Hayashi, K., Murai, N., Koizumi, T., et al. (2008) · World Journal of Surgery · doi:10.1007/s00268-008-9620-y · Cited by 308 · cited 2×
“In 2008, fluorescence imaging following portal injection of ICG was first used in the intraoperative identification of hepatic segments (10).”
BackgroundMethodTransporters involved in the hepatic uptake of 99mTc-mebrofenin and indocyanine green
de Graaf, W., Häusler, S., Heger, M., van Ginhoven, T. M., van Cappellen, G., Bennink, R. J., Kullak-Ublick, G. A., Hesselmann, R., van Gulik, T. M., & Stieger, B. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.07.047 · Cited by 304 · cited 1×
“In differentiated HCC tissues, the expression levels of portal uptake transporters of ICG [organic anion-transporting polypeptide 8 and Na+/taurocholate cotransporting polypeptide (31)] were well preserved, but functional or morphological biliary excretion disorders were present, leading to retention of ICG in cancero…”
BackgroundIshizawa, T., Tamura, S., Masuda, K., Aoki, T., Hasegawa, K., Imamura, H., Beck, Y., & Kokudo, N. (2008) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2008.09.024 · Cited by 281 · cited 3×
“Because human bile contains proteins such as albumin and lipoproteins that bind ICG (18), fluorescent images of the biliary tract can be obtained by intrabiliary injection of ICG (11).”
BackgroundMethodSelf-citationIshizawa, T., Masuda, K., Urano, Y., Kawaguchi, Y., Satou, S., Kaneko, J., Hasegawa, K., Shibahara, J., Fukayama, M., Tsuji, S., et al. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-013-3360-4 · Cited by 253 · cited 3×
“This technique has potential drawbacks, however, including a relatively high false-positive rate [around 40% (13,14)].”
BackgroundSelf-citationDigital Indocyanine-green Angilography in Chorioretinal Disorders
Guyer, D. R., Puliafito, C. A., Monés, J. M., Friedman, E., Chang, W., & Verdooner, S. R. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31981-5 · Cited by 178
Usefulness of intraoperative fluorescence imaging to evaluate local anatomy in hepatobiliary surgery
Mitsuhashi, N., Kimura, F., Shimizu, H., Imamaki, M., Yoshidome, H., Ohtsuka, M., Kato, A., Yoshitomi, H., Nozawa, S., Furukawa, K., et al. (2008) · Journal of Hepato-Biliary-Pancreatic Surgery · doi:10.1007/s00534-007-1307-5 · Cited by 166 · cited 2×
“25 mg/mL, decreasing at higher concentrations because of the absorption of near-infrared light by ICG (9).”
BackgroundInoue, Y., Arita, J., Sakamoto, T., Ono, Y., Takahashi, M., Takahashi, Y., Kokudo, N., & Saiura, A. (2015) · Annals of Surgery · doi:10.1097/sla.0000000000000775 · Cited by 164 · cited 3×
“Refinements in imaging techniques have enabled the use of ICG-fluorescence imaging for visualization of hepatic segments, enabling more accurate anatomic resection of the liver (16,17).”
BackgroundMethodSelf-citationOsayi, S. N., Wendling, M. R., Drosdeck, J. M., Chaudhry, U. I., Perry, K. A., Noria, S. F., Mikami, D. J., Needleman, B. J., Muscarella, P., Abdel-Rasoul, M., et al. (2015) · Surgical Endoscopy · doi:10.1007/s00464-014-3677-5 · Cited by 164
Spinoglio, G., Priora, F., Bianchi, P. P., Lucido, F. S., Licciardello, A., Maglione, V., Grosso, F., Quarati, R., Ravazzoni, F., & Lenti, L. M. (2013) · Surgical Endoscopy · doi:10.1007/s00464-012-2733-2 · Cited by 158
Optimization of near-infrared fluorescence cholangiography for open and laparoscopic surgery
Verbeek, F. P. R., Schaafsma, B. E., Tummers, Q. R. J. G., van der Vorst, J. R., van der Made, W. J., Baeten, C. I. M., Bonsing, B. A., Frangioni, J. V., van de Velde, C. J. �., Vahrmeijer, A. L., et al. (2013) · Surgical Endoscopy · doi:10.1007/s00464-013-3305-9 · Cited by 156 · cited 1×
“Although fluorescence cholangiography has a limitation in detecting small stones floating in the common bile duct, the present technique has recently gained attention as a novel and easy-to-use navigation tool that provides a roadmap of the extrahepatic ducts, enhancing safety (22) during laparoscopic (23-28) and robo…”
BackgroundDaskalaki, D., Fernandes, E., Wang, X., Bianco, F. M., Elli, E. F., Ayloo, S., Masrur, M., Milone, L., & Giulianotti, P. C. (2014) · Surgical Innovation · doi:10.1177/1553350614524839 · Cited by 151 · cited 1×
“Although fluorescence cholangiography has a limitation in detecting small stones floating in the common bile duct, the present technique has recently gained attention as a novel and easy-to-use navigation tool that provides a roadmap of the extrahepatic ducts, enhancing safety (22) during laparoscopic (23-28) and robo…”
BackgroundKudo, H., Ishizawa, T., Tani, K., Harada, N., Ichida, A., Shimizu, A., Kaneko, J., Aoki, T., Sakamoto, Y., Sugawara, Y., et al. (2014) · Surgical Endoscopy · doi:10.1007/s00464-014-3468-z · Cited by 150 · cited 2×
“The intraoperative ICG-fluorescence imaging of hepatic tumors is simple and is especially useful for identifying subcapsular lesions for removal during laparoscopic hepatectomy, in which visual inspection and palpation are limited compared with open surgery (Figure 2) (15).”
BackgroundMethodSelf-citationSatou, S., Ishizawa, T., Masuda, K., Kaneko, J., Aoki, T., Sakamoto, Y., Hasegawa, K., Sugawara, Y., & Kokudo, N. (2012) · Journal of Gastroenterology · doi:10.1007/s00535-012-0709-6 · Cited by 122 · cited 8×
“During the development of fluorescence cholangiography for hepatic tumors, it was found that ICG accumulated in cancerous tissues of hepatocellular carcinoma (HCC) and in non-cancerous hepatic parenchyma around adenocarcinoma foci (13,14).”
MethodInfluentialSelf-citationYokoyama, N., Otani, T., Hashidate, H., Maeda, C., Katada, T., Sudo, N., Manabe, S., Ikeno, Y., Toyoda, A., & Katayanagi, N. (2011) · Cancer · doi:10.1002/cncr.26594 · Cited by 120
Dip, F., Roy, M., Menzo, E. L., Simpfendorfer, C. H., Szomstein, S., & Rosenthal, R. J. (2014) · Surgical Endoscopy · doi:10.1007/s00464-014-3853-7 · Cited by 104 · cited 1×
“Although fluorescence cholangiography has a limitation in detecting small stones floating in the common bile duct, the present technique has recently gained attention as a novel and easy-to-use navigation tool that provides a roadmap of the extrahepatic ducts, enhancing safety (22) during laparoscopic (23-28) and robo…”
BackgroundCombined vascular and biliary fluorescence imaging in laparoscopic cholecystectomy
Schols, R. M., Bouvy, N. D., van Dam, R. M., Masclee, A., Dejong, C. H. C., & Stassen, L. P. S. (2013) · Surgical Endoscopy · doi:10.1007/s00464-013-3100-7 · Cited by 96 · cited 1×
“Although fluorescence cholangiography has a limitation in detecting small stones floating in the common bile duct, the present technique has recently gained attention as a novel and easy-to-use navigation tool that provides a roadmap of the extrahepatic ducts, enhancing safety (22) during laparoscopic (23-28) and robo…”
BackgroundTagaya, N., Shimoda, M., Kato, M., Nakagawa, A., Abe, A., Iwasaki, Y., Oishi, H., Shirotani, N., & Kubota, K. (2009) · Journal of Hepato-Biliary-Pancreatic Sciences · doi:10.1007/s00534-009-0195-2 · Cited by 81 · cited 1×
“Although fluorescence cholangiography has a limitation in detecting small stones floating in the common bile duct, the present technique has recently gained attention as a novel and easy-to-use navigation tool that provides a roadmap of the extrahepatic ducts, enhancing safety (22) during laparoscopic (23-28) and robo…”
BackgroundSources of proteins in human bile.
Mullock, B. M., Shaw, L. J., Fitzharris, B. M., Peppard, J., Hamilton, M. J., Simpson, M. T., Hunt, T. M., & Hinton, R. H. (1985) · Gut · doi:10.1136/gut.26.5.500 · Cited by 73 · cited 1×
“Because human bile contains proteins such as albumin and lipoproteins that bind ICG (18), fluorescent images of the biliary tract can be obtained by intrabiliary injection of ICG (11).”
BackgroundHarada, N., Ishizawa, T., Muraoka, A., Ijichi, M., Kusaka, K., Shibasaki, M., Yamamoto, K., Hasegawa, K., Bandai, Y., & Kokudo, N. (2010) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2010.02.052 · Cited by 67 · cited 1×
“This method can also be used to detect biliary congestion caused by tumor invasion (34), micrometastases from pancreatic cancer (35), and extrahepatic spread of HCC (36).”
MethodSelf-citationExpression of indocyanine green-related transporters in hepatocellular carcinoma
Shibasaki, Y., Sakaguchi, T., Hiraide, T., Morita, Y., Suzuki, A., Baba, S., Setou, M., & Konno, H. (2014) · Journal of Surgical Research · doi:10.1016/j.jss.2014.07.055 · Cited by 55 · cited 1×
“ICG fluorescence of HCC tissues was found associated with a risk of recurrence after hepatectomy (33).”
BackgroundFluorescence Imaging of Human Bile and Biliary Anatomy
Ishizawa, T., & Kokudo, N. (2015) · Springer eBooks · doi:10.1007/978-1-4939-2326-7_22 · Cited by 3 · cited 1×
“When the intrahepatic bile duct anatomy and the extrahepatic biliary system must be identified, ICG should be diluted with radiographic contrast agents, enabling radiographic cholangiography easily and immediately following fluorescence cholangiography (19).”
BackgroundSelf-citation
Cited by
Targeted multicolor in vivo imaging over 1,000 nm enabled by nonamethine cyanines
Bandi, V. G., Luciano, M. P., Saccomano, M., Patel, N. L., Bischof, T. S., Lingg, J. G. P., Tsrunchev, P. T., Nix, M. N., Ruehle, B., Sanders, C., et al. (2022) · Nature Methods · doi:10.1038/s41592-022-01394-6 · Cited by 184
Development of Polyene-Bridged Hybrid Rhodamine Fluorophores for High-Resolution NIR-II Imaging
Shi, Y., Yuan, W., Liu, Q., Kong, M., Li, Z., Feng, W., Hu, K., & Li, F. (2019) · ACS Materials Letters · doi:10.1021/acsmaterialslett.9b00265 · Cited by 80
Metadata
- Authors
- Ishizawa, T., Saiura, A., & Kokudo, N.
- Venue
- HepatoBiliary Surgery and Nutrition
- Publisher
- AME Publishing Company
- Published
- 2016-08
- Volume
- 5
- Issue
- 4
- Pages
- 322-328
- ISSN
- 2304-3881 (ISSN-L)
- 2304-389X
- OpenAlex
- W1856275929
- Cited by
- 183
- References
- 30
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.