The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Mechanistic Background and Clinical Applications of Indocyanine Green Fluorescence Imaging of Hepatocellular Carcinoma
Open accessAbstract
BACKGROUND: Although clinical applications of intraoperative fluorescence imaging of liver cancer using indocyanine green (ICG) have begun, the mechanistic background of ICG accumulation in the cancerous tissues remains unclear. METHODS: In 170 patients with hepatocellular carcinoma cells (HCC), the liver surfaces and resected specimens were intraoperatively examined by using a near-infrared fluorescence imaging system after preoperative administration of ICG (0.5 mg/kg i.v.). Microscopic examinations, gene expression profile analysis, and immunohistochemical staining were performed for HCCs, which showed ICG fluorescence in the cancerous tissues (cancerous-type fluorescence), and HCCs showed fluorescence only in the surrounding non-cancerous liver parenchyma (rim-type fluorescence). RESULTS: ICG fluorescence imaging enabled identification of 273 of 276 (99%) HCCs in the resected specimens. HCCs showed that cancerous-type fluorescence was associated with higher cancer cell differentiation as compared with rim-type HCCs (P < 0.001). Fluorescence microscopy identified the presence of ICG in the canalicular side of the cancer cell cytoplasm, and pseudoglands of the HCCs showed a cancerous-type fluorescence pattern. The ratio of the gene and protein expression levels in the cancerous to non-cancerous tissues for Na(+)/taurocholate cotransporting polypeptide (NTCP) and organic anion-transporting polypeptide 8 (OATP8), which are associated with portal uptake of ICG by hepatocytes that tended to be higher in the HCCs that showed cancerous-type fluorescence than in those that showed rim-type fluorescence. CONCLUSIONS: Preserved portal uptake of ICG in differentiated HCC cells by NTCP and OATP8 with concomitant biliary excretion disorders causes accumulation of ICG in the cancerous tissues after preoperative intravenous administration. This enables highly sensitive identification of HCC by intraoperative ICG fluorescence imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subramanian, A., Tamayo, P., Mootha, V. K., Mukherjee, S., Ebert, B. L., Gillette, M. A., Paulovich, A., Pomeroy, S. L., Golub, T. R., Lander, E. S., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0506580102 · Cited by 53,625
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Terminology of nodular hepatocellular lesions
Wanless, I. R. (1995) · Hepatology · doi:10.1002/hep.1840220341 · Cited by 1,130
Real‐time identification of liver cancers by using indocyanine green fluorescent imaging
Ishizawa, T., Fukushima, N., Shibahara, J., Masuda, K., Tamura, S., Aoki, T., Hasegawa, K., Beck, Y., Fukayama, M., & Kokudo, N. (2009) · Cancer · doi:10.1002/cncr.24291 · Cited by 852
Self-citationLight-absorbing properties, stability, and spectral stabilization of indocyanine green
Landsman, M. L., Kwant, G., Mook, G. A., & Zijlstra, W. G. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.4.575 · Cited by 834
Surgery for small liver cancers
Makuuchi, M., Kosuge, T., Takayama, T., Yamazaki, S., Kakazu, T., Miyagawa, S., & Kawasaki, S. (1993) · Seminars in Surgical Oncology · doi:10.1002/ssu.2980090404 · Cited by 790
Ishizawa, T., Hasegawa, K., Aoki, T., Takahashi, M., Inoue, Y., Sano, K., Imamura, H., Sugawara, Y., Kokudo, N., & Makuuchi, M. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.02.091 · Cited by 754
Self-citationWalter, S., Susanne, S., Simon, W., Herbert, S., Clemens, F., Claudia, G., Alwin, E. G., Rainer, K., & Hans, J. R. (1998) · Neurosurgery · doi:10.1097/00006123-199803000-00017 · Cited by 690
Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 640
Cairo, S., Armengol, C., De Reyniès, A., Wei, Y., Thomas, E., Renard, C.-A., Goga, A., Balakrishnan, A., Semeraro, M., Gresh, L., et al. (2008) · Cancer Cell · doi:10.1016/j.ccr.2008.11.002 · Cited by 509
Cited by
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
Chi, C., Du, Y., Ye, J., Kou, D., Qiu, J., Wang, J., Tian, J., & Chen, X. (2014) · Theranostics · doi:10.7150/thno.9899 · Cited by 358
van Manen, L., Handgraaf, H. J. M., Diana, M., Dijkstra, J., Ishizawa, T., Vahrmeijer, A. L., & Mieog, J. S. D. (2018) · Journal of Surgical Oncology · doi:10.1002/jso.25105 · Cited by 322
Self-citationShi, C., Wu, J. B., & Pan, D. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.5.050901 · Cited by 286
Consensus Guidelines for the Use of Fluorescence Imaging in Hepatobiliary Surgery
Wang, X., Teh, C. S. C., Ishizawa, T., Aoki, T., Cavallucci, D., Lee, S.-Y., Panganiban, K. M., Perini, M. V., Shah, S. R., Wang, H., et al. (2021) · Annals of Surgery · doi:10.1097/sla.0000000000004718 · Cited by 256
Self-citation
Metadata
- Authors
- Ishizawa, T., Masuda, K., Urano, Y., Kawaguchi, Y., Satou, S., Kaneko, J., Hasegawa, K., Shibahara, J., Fukayama, M., Tsuji, S., Midorikawa, Y., Aburatani, H., & Kokudo, N.
- Venue
- Annals of Surgical Oncology
- Published
- 2013-11-20
- Volume
- 21
- Issue
- 2
- Pages
- 440-448
- ISSN
- 1068-9265 (ISSN-L)
- 1534-4681
- OpenAlex
- W2067721149
- Cited by
- 253
- References
- 21
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanistic Background and Clinical Applications of Indocyanine Green Fluorescence Imaging of Hepatocellular Carcinoma. https://app.cochat.ai/papers/10.1245/s10434-013-3360-4
- The paper
- Ishizawa, T., Masuda, K., Urano, Y., Kawaguchi, Y., Satou, S., Kaneko, J., Hasegawa, K., Shibahara, J., Fukayama, M., Tsuji, S., Midorikawa, Y., Aburatani, H., & Kokudo, N. (2014). Mechanistic Background and Clinical Applications of Indocyanine Green Fluorescence Imaging of Hepatocellular Carcinoma. Annals of Surgical Oncology. https://doi.org/10.1245/s10434-013-3360-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.