Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
A comprehensive literature review was performed on liver intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) technique and its applications. Heterogeneous data have been reported. IVIM parameters are magnetic field strength dependent to a mild extent. A lower Dslow (D) value at 3 T than at 1.5 T and higher perfusion fraction (PF) value at 3 T than at 1.5 T were noted. An increased number of b values are associated with increased IVIM parameter measurement accuracy. With the current status of art, IVIM technique is not yet capable of detecting early stage liver fibrosis and diagnosing liver fibrosis grades, nor can it differentiate liver tumors. Though IVIM parameters show promise for tumor treatment monitoring, till now how PF and Dfast (D*) add diagnostic value to Dslow or apparent diffusion coefficient (ADC) remains unclear. This paper shows the state-of-art IVIM MR technique is still not able to offer reliable measurement for liver. More works on the measurement robustness are warranted as they are essential to justify follow-up clinical studies on patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 2×
“(1,3) proposed the principle of IVIM which enables the quantitative parameters that separately reflect tissue diffusivity and tissue microcapillary perfusion to be estimated.”
BackgroundSeparation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169 · cited 4×
“In the presence of a magnetic field gradient, diffusion of water molecules causes a phase dispersion of the transverse magnetization, which results in the attenuation of the MRI signal (1).”
BackgroundInfluentialDiffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993 · cited 1×
“Initially, the diffusion effect was described by a mono-exponential decay model (2).”
BackgroundGreenway, C. V., & Stark, R. D. (1971) · Physiological Reviews · doi:10.1152/physrev.1971.51.1.23 · Cited by 633 · cited 2×
“It is estimated that hepatic artery accounts for 1%, portal vein for 5%, hepatic vein for 5%, and small-vessel content for 14% of blood flow (25,29-32).”
BackgroundLiver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612 · cited 5×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodInfluentialYamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519 · cited 2×
“The advent of respiratory gating combined with parallel imaging allows IVIM MRI to be attempted in the evaluation of abdominal organs, such as liver (7-12).”
BackgroundThe capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423 · cited 1×
“However, perfusion can contribute to the diffusion measurements significantly because of the incoherent motion of blood in pseudorandom capillary network at the macroscopic level (1,3-5).”
BackgroundPatel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371 · cited 3×
“(12) reported that the value of Dslow, PF and Dfast in liver cirrhosis were lower than non-cirrhosis liver; however, no further grading was performed within their liver cirrhosis subjects as only three patients had histopathology data.”
BackgroundMethodLe Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288 · cited 1×
“However, perfusion can contribute to the diffusion measurements significantly because of the incoherent motion of blood in pseudorandom capillary network at the macroscopic level (1,3-5).”
BackgroundAndreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287 · cited 3×
“It has been shown in previous IVIM studies that it is more stable against signal fluctuations than least-squares fitting approach, especially when SNR is low (17,38,56).”
Background
Metadata
- Authors
- Li, Y. T., Cercueil, J.-P., Yuan, J., Chen, W., Loffroy, R., & Wáng, Y. X. J.
- Venue
- Quantitative Imaging in Medicine and Surgery
- Publisher
- AME Publishing Company
- Published
- 2017-02
- Volume
- 7
- Issue
- 1
- Pages
- 59-78
- ISSN
- 2223-4292 (ISSN-L)
- 2223-4306
- OpenAlex
- W2594758671
- Cited by
- 162
- References
- 55
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation. https://app.cochat.ai/papers/10.21037/qims.2017.02.03
- The paper
- Li, Y. T., Cercueil, J.-P., Yuan, J., Chen, W., Loffroy, R., & Wáng, Y. X. J. (2017). Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation. Quantitative Imaging in Medicine and Surgery. https://doi.org/10.21037/qims.2017.02.03
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).