Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
A comprehensive literature review was performed on liver intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) technique and its applications. Heterogeneous data have been reported. IVIM parameters are magnetic field strength dependent to a mild extent. A lower Dslow (D) value at 3 T than at 1.5 T and higher perfusion fraction (PF) value at 3 T than at 1.5 T were noted. An increased number of b values are associated with increased IVIM parameter measurement accuracy. With the current status of art, IVIM technique is not yet capable of detecting early stage liver fibrosis and diagnosing liver fibrosis grades, nor can it differentiate liver tumors. Though IVIM parameters show promise for tumor treatment monitoring, till now how PF and Dfast (D*) add diagnostic value to Dslow or apparent diffusion coefficient (ADC) remains unclear. This paper shows the state-of-art IVIM MR technique is still not able to offer reliable measurement for liver. More works on the measurement robustness are warranted as they are essential to justify follow-up clinical studies on patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 2×
“(1,3) proposed the principle of IVIM which enables the quantitative parameters that separately reflect tissue diffusivity and tissue microcapillary perfusion to be estimated.”
BackgroundSeparation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169 · cited 4×
“In the presence of a magnetic field gradient, diffusion of water molecules causes a phase dispersion of the transverse magnetization, which results in the attenuation of the MRI signal (1).”
BackgroundInfluentialDiffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993 · cited 1×
“Initially, the diffusion effect was described by a mono-exponential decay model (2).”
BackgroundGreenway, C. V., & Stark, R. D. (1971) · Physiological Reviews · doi:10.1152/physrev.1971.51.1.23 · Cited by 633 · cited 2×
“It is estimated that hepatic artery accounts for 1%, portal vein for 5%, hepatic vein for 5%, and small-vessel content for 14% of blood flow (25,29-32).”
BackgroundLiver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612 · cited 5×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodInfluentialYamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519 · cited 2×
“The advent of respiratory gating combined with parallel imaging allows IVIM MRI to be attempted in the evaluation of abdominal organs, such as liver (7-12).”
BackgroundThe capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423 · cited 1×
“However, perfusion can contribute to the diffusion measurements significantly because of the incoherent motion of blood in pseudorandom capillary network at the macroscopic level (1,3-5).”
BackgroundPatel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371 · cited 3×
“(12) reported that the value of Dslow, PF and Dfast in liver cirrhosis were lower than non-cirrhosis liver; however, no further grading was performed within their liver cirrhosis subjects as only three patients had histopathology data.”
BackgroundMethodLe Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288 · cited 1×
“However, perfusion can contribute to the diffusion measurements significantly because of the incoherent motion of blood in pseudorandom capillary network at the macroscopic level (1,3-5).”
BackgroundAndreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287 · cited 3×
“It has been shown in previous IVIM studies that it is more stable against signal fluctuations than least-squares fitting approach, especially when SNR is low (17,38,56).”
BackgroundToward an optimal distribution of b values for intravoxel incoherent motion imaging
Lemke, A., Stieltjes, B., Schad, L. R., & Laun, F. B. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.03.004 · Cited by 286 · cited 3×
“Including more b values and applying an optimized b value distribution reduces errors in the IVIM parameter estimates (16,34,49).”
BackgroundMethodLemke, A., Laun, F. B., Simon, D., Stieltjes, B., & Schad, L. R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22565 · Cited by 266 · cited 2×
“(33) demonstrated that overestimation of PF is dependent on echo time.”
BackgroundMulti-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain
Grech‐Sollars, M., Hales, P. W., Miyazaki, K., Raschke, F., Rodriguez, D., Wilson, M., Gill, S. K., Banks, T., Saunders, D. E., Clayden, J. D., et al. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3269 · Cited by 213 · cited 2×
“(13) demonstrated that compared with apparent diffusion coefficient (ADC) and diffusion tensor imaging (DTI) parameters, the IVIM parameter PF had a high intra-scanner coefficient of variation (CoV) of 8.”
BackgroundBearn, A. G., Billing, B., & Sherlock, S. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004679 · Cited by 204
Dyvorne, H. A., Galea, N., Nevers, T., Fiel, M. I., Carpenter, D., Wong, E., Orton, M., de Oliveira, A., Feiweier, T., Vachon, M.-L., et al. (2013) · Radiology · doi:10.1148/radiol.12120686 · Cited by 182 · cited 7×
“Additionally, left lobe may be more prone to cardiac motion artifacts which potentially can alter diffusion measurement (15).”
BackgroundMethodInfluentialDiffusion‐weighted imaging outside the brain: Consensus statement from an ISMRM‐sponsored workshop
Taouli, B., Beer, A. J., Chenevert, T., Collins, D., Lehman, C., Matos, C., Padhani, A. R., Rosenkrantz, A. B., Shukla‐Dave, A., Sigmund, E., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25196 · Cited by 175 · cited 2×
“The recent ISMRM-Sponsored Workshop Consensus Statement on DW imaging outside the brain did not propose an IVIM data acquisition protocol (36).”
MethodResultGuiu, B., Petit, J.-M., Capitan, V., Aho, S., Masson, D., Lefevre, P.-H., Favelier, S., Loffroy, R., Vergès, B., Hillon, P., et al. (2012) · Radiology · doi:10.1148/radiol.12112478 · Cited by 169
Self-citationOn the precision of diffusion/perfusion imaging by gradient sensitization
Pekar, J. J., MOONEN, C. T. W., & van Zijl, P. C. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230113 · Cited by 163 · cited 1×
“(39) commented that Dfast in particular tends to be unstable unless an unrealistically high SNR is achieved.”
BackgroundNeil, J. J., & Bretthorst, G. L. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290510 · Cited by 151 · cited 2×
“It has been shown in previous IVIM studies that it is more stable against signal fluctuations than least-squares fitting approach, especially when SNR is low (17,38,56).”
BackgroundMethodLee, Y., Lee, S. S., Kim, N., Kim, E., Kim, Y. J., Yun, S., Kühn, B., Kim, I. S., Park, S. H., Kim, S. Y., et al. (2014) · Radiology · doi:10.1148/radiol.14140759 · Cited by 124
Kakite, S., Dyvorne, H., Besa, C., Cooper, N., Facciuto, M. E., Donnerhack, C., & Taouli, B. A. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24538 · Cited by 121 · cited 5×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodInfluentialBarbieri, S., Donati, O. F., Froehlich, J. M., & Thoeny, H. C. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25765 · Cited by 115 · cited 3×
“It has been shown in previous IVIM studies that it is more stable against signal fluctuations than least-squares fitting approach, especially when SNR is low (17,38,56).”
BackgroundResultLiver fibrosis: An intravoxel incoherent motion (IVIM) study
Chow, A. M., Gao, D. S., Fan, S. J., Qiao, Z., Lee, F. Y., Yang, J., Man, K., & Wu, E. X. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23607 · Cited by 114 · cited 1×
“(58) reported that as liver fibrosis progressed, Dslow and Dfast decreased, however there was no change in PF.”
BackgroundWurnig, M. C., Donati, O. F., Ulbrich, E. J., Filli, L., Kenkel, D., Thoeny, H. C., & Boss, A. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25506 · Cited by 95 · cited 7×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodInfluentialJoo, I., Lee, J. M., Han, J. K., & Choi, B. I. (2014) · Radiology · doi:10.1148/radiol.14131165 · Cited by 89 · cited 1×
“(61) demonstrated PF and Dslow significantly decreased 4 hours after administration of a VDA (CKD516, Chong Kun Dang Pharmaceutical Corp.”
BackgroundDyvorne, H., Jajamovich, G. H., Kakite, S., Kuehn, B., & Taouli, B. A. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2014.09.003 · Cited by 86 · cited 3×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodLiver diffusion-weighted MR imaging: the tower of Babel?
Guiu, B., & Cercueil, J. (2010) · European Radiology · doi:10.1007/s00330-010-2017-y · Cited by 84
Self-citationIchikawa, S., Motosugi, U., Morisaka, H., Sano, K., Ichikawa, T., Enomoto, N., Matsuda, M., Fujii, H., & Onishi, H. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24760 · Cited by 81
Jerome, N. P., Orton, M. R., d’Arcy, J. A., Collins, D. J., Koh, D., & Leach, M. O. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24140 · Cited by 75 · cited 2×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodMurphy, P. M., Hooker, J. C., Ang, B., Wolfson, T. J., Gamst, A. C., Bydder, M., Middleton, M. S., Peterson, M. R., Behling, C. A., Loomba, R. S., et al. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24755 · Cited by 70 · cited 1×
“According to IVIM theory, diffusion and perfusion are affected by several tissue characteristics, including the presence of restrictive barriers within tissue, the viscosity of the fluid in which the spins are diffusing, and the velocity and fractional volume of perfusing spins (6).”
BackgroundCercueil, J., Petit, J., Nougaret, S., Soyer, P. A., Fohlen, A., Pierredon-Foulongne, M. A., Schembri, V., Delhom, E., Schmidt, S., Denys, A. L., et al. (2014) · European Radiology · doi:10.1007/s00330-014-3554-6 · Cited by 68 · cited 5×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodSelf-citationOptimization of intra-voxel incoherent motion imaging at 3.0 Tesla for fast liver examination
Leporq, B., Saint‐Jalmes, H., Rabrait‐Lerman, C., Pilleul, F., Guillaud, O., Dumortier, J., Scoazec, J., & Beuf, O. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24693 · Cited by 68 · cited 3×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodJoo, I., Lee, J. M., Yoon, J. H., Jang, J. J., Han, J. K., & Choi, B. I. (2013) · Radiology · doi:10.1148/radiol.13122506 · Cited by 67
Delattre, B. M. A., Viallon, M., Wei, H., Zhu, Y., Feiweier, T., Pai, V. M., Wen, H., & Croisille, P. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e31826ef901 · Cited by 62 · cited 2×
“Only one study had breath-holding for a block of b values (44).”
BackgroundFrança, M., Martí‐Bonmatí, L., Alberich‐Bayarri, Á., Oliveira, P., Guimarães, S., de Oliveira, J. P. F., Amorim, J., Sánchez‐Gonzalez, J., Vizcaino, J. R., & Miranda, H. (2016) · Abdominal Radiology · doi:10.1007/s00261-016-0899-0 · Cited by 60 · cited 4×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodInfluentialLu, P.-X., Huang, H., Yuan, J., Zhao, F., Chen, Z., Zhang, Q., Ahuja, A. T., Zhou, B., & Wáng, Y. X. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0113846 · Cited by 58 · cited 6×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodSelf-citationIntravoxel incoherent motion MRI for liver fibrosis assessment: a pilot study
Chung, S. R., Lee, S. S., Kim, N., Yu, E. S., Kim, E., Kühn, B., & Kim, I. S. (2014) · Acta Radiologica · doi:10.1177/0284185114559763 · Cited by 56 · cited 3×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodKlauß, M., Mayer, P., Maier-Hein, K. H., Laun, F. B., Mehrabi, A., Kauczor, H., & Stieltjes, B. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.04.011 · Cited by 55
Medical imaging in pharmaceutical clinical trials: what radiologists should know
Wáng, Y. X. J. (2005) · Clinical Radiology · doi:10.1016/j.crad.2005.04.016 · Cited by 54 · cited 1×
“A prerequisite to translating the growing interest in IVIM imaging into clinical applications is its accurate measurement of normative value of IVIM parameters and acceptable reproducibility across different clinical settings (13,14).”
BackgroundSelf-citationIVIM diffusion-weighted imaging of the liver at 3.0T: Comparison with 1.5T
Cui, Y., Dyvorne, H., Besa, C., Cooper, N., & Taouli, B. A. (2015) · European Journal of Radiology Open · doi:10.1016/j.ejro.2015.08.001 · Cited by 52 · cited 3×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodter Voert, E. E. G. W., Delso, G., Porto, M., Huellner, M. W., & Veit‐Haibach, P. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000207 · Cited by 52 · cited 9×
“in normal-appearing tissue could also be partially explained by motion and partial volume (34).”
BackgroundMethodResultInfluentialBarbieri, S., Donati, O. F., Froehlich, J. M., & Thoeny, H. C. (2015) · Radiology · doi:10.1148/radiol.2015151244 · Cited by 50 · cited 2×
“found that the use of RT did not have a significant effect on the measured parameter values (37).”
BackgroundResultJoo, I., Lee, J. M., Grimm, R., Han, J. K., & Choi, B. I. (2015) · Radiology · doi:10.1148/radiol.2015141974 · Cited by 49
Gurney‐Champion, O. J., Froeling, M., Klaassen, R., Runge, J. H., Bel, A., van Laarhoven, H. W. M., Stoker, J., & Nederveen, A. J. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000225 · Cited by 40 · cited 3×
“Including more b values and applying an optimized b value distribution reduces errors in the IVIM parameter estimates (16,34,49).”
BackgroundMethodZhu, L., Cheng, Q., Luo, W., Bao, L., & Guo, G. (2014) · Acta Radiologica · doi:10.1177/0284185114559426 · Cited by 39 · cited 3×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodWhole-body intravoxel incoherent motion imaging
Filli, L., Wurnig, M. C., Luechinger, R., Eberhardt, C., Guggenberger, R., & Boss, A. (2015) · European Radiology · doi:10.1007/s00330-014-3577-z · Cited by 37 · cited 5×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodInfluentialYang, S., Lin, J., Lü, F., Han, Z., Fu, C., Lv, P., Liu, H., & Gao, D. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25344 · Cited by 34 · cited 1×
“(63) reported the usefulness of PF for the assessment of the therapeutic eff icacy of Sorafenib (Nexavar, Bayer and Onyx Pharmaceuticals) in a mice orthotopic HCC model, before and after 6 weeks each treatment was performed at 1.”
BackgroundIntra-voxel incoherent motion MRI in rodent model of diethylnitrosamine-induced liver fibrosis
Zhang, Y., Jin, N., Deng, J., Guo, Y., White, S. B., Yang, G., Omary, R. A., & Larson, A. C. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.03.007 · Cited by 33 · cited 1×
“(57) reported that PF values decreased significantly with the increasing fibrosis level; but Dslow was poorly correlated with fibrosis level.”
BackgroundTaimouri, V., Afacan, O., Pérez-Rosselló, J. M., Callahan, M. J., Mulkern, R. V., Warfield, S. K., & Freiman, M. (2015) · Medical Physics · doi:10.1118/1.4915495 · Cited by 32 · cited 2×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodGambarota, G., Hitti, E., Leporq, B., Saint‐Jalmes, H., & Beuf, O. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26085 · Cited by 30 · cited 2×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
MethodMedical imaging in new drug clinical development.
Wáng, Y. X. J., & Deng, M. (2010) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2072-1439.2010.11.10 · Cited by 28 · cited 1×
“Contrast-enhanced ultrasonography, computed tomography, and MRI have been used to quantify tumor perfusion before and after antivascular treatments, and decrease in such imaging parameters has been demonstrated in responders (60).”
MethodSelf-citationPieper, C. C., Sprinkart, A. M., Meyer, C. H., König, R., Schild, H. H., Kukuk, G. M., & Mürtz, P. (2016) · Medicine · doi:10.1097/md.0000000000003275 · Cited by 28
Regional blood flow in rats after a single low-protein, high-carbohydrate test meal
Glick, Z., Wickler, S. J., Stern, J. S., & Horwitz, B. A. (1984) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1984.247.1.r160 · Cited by 23 · cited 1×
“It is estimated that hepatic artery accounts for 1%, portal vein for 5%, hepatic vein for 5%, and small-vessel content for 14% of blood flow (25,29-32).”
BackgroundRegini, F., Colagrande, S., Mazzoni, L. N., Busoni, S., Matteuzzi, B., Santini, P., & Wyttenbach, R. (2015) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000220 · Cited by 23 · cited 4×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethodInfluentialWurnig, M. C., Kenkel, D., Filli, L., & Boss, A. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000223 · Cited by 17 · cited 3×
“Various fitting algorithms have been used to determine IVIM parameters, including asymptotic fitting (9-12,19-21,24,41,45,46,48,51,53), nonlinear least square (usually Levenberg-Marquardt) fitting (23,42,47,52,54,55), and Bayesian fitting (15,22,40,43,50).”
BackgroundMethod
Metadata
- Authors
- Li, Y. T., Cercueil, J.-P., Yuan, J., Chen, W., Loffroy, R., & Wáng, Y. X. J.
- Venue
- Quantitative Imaging in Medicine and Surgery
- Publisher
- AME Publishing Company
- Published
- 2017-02
- Volume
- 7
- Issue
- 1
- Pages
- 59-78
- ISSN
- 2223-4292 (ISSN-L)
- 2223-4306
- OpenAlex
- W2594758671
- Cited by
- 162
- References
- 55
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.