TRANSVERSE ROTATION OF THE SEGMENTS OF THE LOWER EXTREMITY IN LOCOMOTION
The DOI matches its Crossref record.
Abstract
Transverse rotations of the pelvis, femur, and tibia occur in all normal individuals (Table IV). Inward and outward rotations of the segments are related to weight-bearing. Inward rotation takes place during the phase from minimal weight-bearing to full weight-bearing, and outward rotation occurs during the phase from full weight-bearing to minimal load. The rotations of the lower extremity appear to be absorbed in the articulations of the foot and their related ligamentous structures. Restrictions placed upon the normal transverse rotations will, to varying degrees, modify the synchrony and rhythm of walking. The awkwardness and discomfort of a patient, required to wear a leg brace which does not provide for these rotations at the hip, knee, and foot, are no doubt due, in part, to the restriction of these motions. At the present time no prosthesis for the lower extremity has purposely incorporated mechanisms to provide for transverse rotatory motions, except on an experimental basis. Suppressing this rotation prevents the prosthesis from approaching the behavior of a normal extremity, and thus requires alterations in the normal pattern of movement of the joints proximal to the amputation. Relative motion will take place where the resistance to torque is the least. During weight-bearing in the stance phase, this motion will tend to occur between the stump and the socket, producing a most uncomfortable force on the stump. This is particularly true of the above-the-knee suction-socket limb. In the below-the-knee amputee, in addition to the major rotations that occur between the trunk and the fixed foot position, there is further restriction of rotatory motion at the knee, produced by the side hinge bars connecting the thigh lacer and the shank. In the case of below-the-knee amputees who have adequate stump length and shape, the use of suction sockets and an ankle mechanism may make it possible not only to provide for transverse rotation, but also to do away with side hinge bars and lacers, which tend to restrict the normal action of the knee. The incorporation of a simple mechanism which provides for transverse rotation of sufficient magnitude, together with a unit for the return of the foot to the normal position, may well constitute a major contribution to both the comfort of the amputee and the improvement of function and synchrony in walking. An experimental mechanism has been used on this project. All amputees who have employed this mechanism have attested to the very marked improvement in comfort. Figure 8 shows reproductions of frames, taken from high-speed motion pictures, of an amputee using the experimental rotatory mechanism. The frames selected for reproduction show the six salient positions of the foot during the stance phase. Attention should be called to changes in the gap (A) between the stops; the width of the gap shows the amount of rotation occurring between the leg and the foot. The ultimate incorporation of this device, or modifications of it, in a prosthesis may well become standard practice, and may be advantageous in leg braces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,055
Powers, C. M. (2003) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2003.33.11.639 · Cited by 995
Brubaker, C. E., & James, S. L. (1974) · The Journal of Sports Medicine · doi:10.1177/036354657400200402 · Cited by 807
James, S. L., Bates, B. T., & Osternig, L. R. (1978) · The American Journal of Sports Medicine · doi:10.1177/036354657800600202 · Cited by 792
Three-dimensional kinematics of the human knee during walking
Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., & Kalenak, A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90254-x · Cited by 694
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
“To measure the angular movement of the bones themselves reflective markers, light sources or goniometers have therefore been fixed to pins driven into the bones (Levens et al., 1948; Reinschmidt et al., 1997a, b; Ishii et al., 1997; Lafortune et al., 1992).”
BackgroundZeller, B. L., McCrory, J. L., Ben Kibler, W., & Uhl, T. L. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310032101 · Cited by 490
Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo
Benoit, D. L., Ramsey, D. K., Lamontagne, M., Xu, L., Wretenberg, P., & Renström, P. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.04.012 · Cited by 489
Effect of skin movement on the analysis of skeletal knee joint motion during running
Reinschmidt, C., van den Bogert, A. J., Nigg, B. M., Lundberg, A., & Murphy, N. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00001-8 · Cited by 475
Johal, P., Williams, A., Wragg, P., Hunt, D., & Gedroyc, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.008 · Cited by 360
Gender discrimination in biological motion displays based on dynamic cues
(1994) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1994.0173 · Cited by 353
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325
The evolution of clinical gait analysis
Sutherland, D. H. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00004-8 · Cited by 314
Stagni, R., Fantozzi, S., Cappello, A., & Leardini, A. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.11.012 · Cited by 283
Comparison of Gait of Young Men and Elderly Men
Blanke, D. J., & Hageman, P. A. (1989) · Physical Therapy · doi:10.1093/ptj/69.2.144 · Cited by 271
Tibiofemoral and tibiocalcaneal motion during walking: external vs. skeletal markers
Reinschmidt, C., van den Bogert, A. J., Lundberg, A., Nigg, B. M., Murphy, N., Stacoff, A., & Stano, A. (1997) · Gait & Posture · doi:10.1016/s0966-6362(97)01110-7 · Cited by 257
Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment
Piazza, S. J., & Cavanagh, P. R. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00056-7 · Cited by 244
Biomechanical effects of wearing high-heeled shoes
Lee, C.-M., Jeong, E.-H., & Freivalds, A. (2001) · International Journal of Industrial Ergonomics · doi:10.1016/s0169-8141(01)00038-5 · Cited by 210
Current Concepts Clinical Evaluation of Patients With Patellofemoral Disorders
Post, W. R. (1999) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/ar.1999.v15.015084 · Cited by 207
Knee biomechanics and total knee replacement
Andriacchi, T. P., Stanwyck, T. S., & Galante, J. O. (1986) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(86)80033-x · Cited by 197
Surface movement errors in shank kinematics and knee kinetics during gait
Holden, J. P., Orsini, J. A., Siegel, K. L., Kepple, T. M., Gerber, L. H., & Stanhope, S. J. (1997) · Gait & Posture · doi:10.1016/s0966-6362(96)01088-0 · Cited by 180
Three-dimensional acceleration of the tibia during walking and running
Lafortune, M. A. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90166-k · Cited by 169
Tibiocalcaneal motion during running, measured with external and bone markers
Reinschmidt, C., van den Bogert, A., Murphy, N., Lundberg, A., & Nigg, B. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(96)00046-0 · Cited by 161
Dwyer, M. K., Boudreau, S. N., Mattacola, C. G., Uhl, T. L., & Lattermann, C. (2010) · Journal of Athletic Training · doi:10.4085/1062-6050-45.2.181 · Cited by 116
Metadata
- Authors
- Levens, A. S., Inman, V. T., & Blosser, J. A.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1948-10
- Volume
- 30
- Issue
- 4
- Pages
- 859-872
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2277786500
- Cited by
- 225
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.