Ten-year follow-up study of total hip replacement.
Open accessThe DOI matches its Crossref record.
Abstract
Of the first 300 consecutive patients who had a Charnley total hip replacement at the Mayo Clinic during the years 1960 to 1970, 207 (231 hips) were re-evaluated ten years postoperative by questionnaire and roentgenograms. Forty-three of these were also evaluated by personal examination. Roentgenographic loosening of the acetabular component was determined using the criterion of a complete radiolucent line more than one millimeter in width at the bone-cement interface or any migration or tilting of the component. For the femoral component, the criterion for loosening was a radiolucent line more than one millimeter wide at either the bone-cement or the cement-prosthesis interface, or any change in the position of the component. As previously reported, the incidence of loose components at five years was 6.5 per cent for the acetabular component and 24 per cent for the femoral component. At ten years the incidence of loosening had increased to 11.3 per cent for the acetabular component and 29.9 per cent for the femoral component. Therefore, between five and ten years postoperatively the rate of femoral loosening decreased, while the rate of acetabular loosening remained about the same. The overall-revision rate for loosening of total hip components increased from 3 per cent at five years to 7.4 per cent at ten years. Acetabular wear was not a significant problem. Resorption of the medial femoral cortex near the calcar was generally non-progressive and was not significantly related to loosening. two modes of loosening are suggested, the more common being cracking of the cement mantle due to circumferential (hoop) stresses within the cement. This series probably represents a so-called worst-case experience, since changes in design and materials as well as the improvements in surgical technique that have evolved over the past decade should provide significantly better long-term fixation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Why we need observational studies to evaluate the effectiveness of health care
Black, N. (1996) · BMJ · doi:10.1136/bmj.312.7040.1215 · Cited by 1,598
Non-traumatic avascular necrosis of the femoral head.
Mont, M. A., & Hungerford, D. S. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199503000-00018 · Cited by 1,191
Total Hip and Total Knee Replacement
Harris, W. H., & Sledge, C. B. (1990) · New England Journal of Medicine · doi:10.1056/nejm199009133231106 · Cited by 553
Current concepts on osteonecrosis of the femoral head
Moya-Angeler, J. (2015) · World Journal of Orthopedics · doi:10.5312/wjo.v6.i8.590 · Cited by 548
Core Decompression Versus Nonoperative Management for Osteonecrosis of the Hip
Mont, M. A., Carbone, J. J., & Fairbank, A. C. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199603000-00020 · Cited by 527
Schulte, K. R., Callaghan, J. J., Kelley, S. S., & Johnston, R. C. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00002 · Cited by 510
Inflammatory Responses to Biomaterials
Tang, L., & Eaton, J. W. (1995) · American Journal of Clinical Pathology · doi:10.1093/ajcp/103.4.466 · Cited by 481
Quantitative Assessment of Walking Activity after Total Hip or Knee Replacement*
SCHMALZRIED, T. P., SZUSZCZEWICZ, E. S., NORTHFIELD, M. R., AKIZUKI, K. H., FRANKEL, R. E., BELCHER, G., & AMSTUTZ, H. C. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199801000-00010 · Cited by 434
Tao, H., Hwang, S.-W., Marelli, B., An, B., Moreau, J. E., Yang, M., Brenckle, M. A., Kim, S., Kaplan, D. L., Rogers, J. A., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1407743111 · Cited by 337
Osteolysis and particle disease in hip replacement: A review
Harris, W. H. (1994) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679408993734 · Cited by 319
Rationalizing the design of polymeric biomaterials
Angelova, N., & Hunkeler, D. (1999) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01356-6 · Cited by 318
The Various Stress Patterns of Press-Fit, Ingrown, and Cemented Femoral Stems
HUISKES, R. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199012000-00006 · Cited by 308
Bone cements and fillers: A review
Kenny, S. M., & Buggy, M. (2003) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1026394530192 · Cited by 294
The 100 classic papers of orthopaedic surgery: A BIBLIOMETRIC ANALYSIS
Kelly, J. C., Glynn, R. W., O’Briain, D. E., Felle, P., & McCabe, J. P. (2010) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.92b10.24867 · Cited by 232
Failed innovation in total hip replacement: Diagnosis and proposals for a cure
Huiskes, R. (1993) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679308994602 · Cited by 215
“This scenario was emphasized as a mechanism of loosening of cemented THR by Stauffer (1982) and played a dominant role in the concepts of THR endurance for many years (Figure 1).”
Mankin, H. J., Gebhardt, M. C., & Tomford, W. W. (1987) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)30391-6 · Cited by 215
Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*
YOON, T. R., ROWE, S. M., JUNG, S. T., SEON, K. J., & MALONEY, W. J. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199810000-00007 · Cited by 169
Strains and micromotions of press-fit femoral stem prostheses
Walker, P. S., Schneeweis, D., Murphy, S., & Nelson, P. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90035-2 · Cited by 169
MONT, M. A., FAIRBANK, A. C., KRACKOW, K. A., & HUNGERFORD, D. S. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199607000-00007 · Cited by 167
Metadata
- Authors
- Stauffer, R. N.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1982-09
- Volume
- 64
- Issue
- 7
- Pages
- 983-990
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W204956869
- Cited by
- 639
- References
- 0
- FWCI
- 16.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.