The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
We investigated the relationship between the toxic effects of metal wear particles and their ability to stimulate the release of inflammatory mediators implicated in bone resorption. In vitro studies were carried out with use of rat peritoneal macrophages, which were exposed to either cobalt-chromium-alloy or titanium-aluminum-vanadium particles, milled from the metal components of hip prostheses. The particles were in the size-range of, and at concentrations similar to, those found in the tissues surrounding failed prostheses in humans. The titanium-aluminum-vanadium particles showed little toxicity even at high concentrations, while the cobalt-chromium particles were very toxic. The titanium-aluminum-vanadium particles induced significantly more release of prostaglandin E2 than did the cobalt-chromium particles, and this was true for a wide range of concentrations. Exposure to titanium-aluminum-vanadium increased the release of prostaglandin E2, interleukin-1, tumor necrosis factor, and interleukin-6. In contrast, exposure to cobalt-chromium particles was associated with a decreased release of prostaglandin E2 and interleukin-6, and it had little effect on the release of interleukin-1 and tumor necrosis factor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lactic Dehydrogenase Activity in Blood.
Wroblewski, F., & Ladue, J. S. (1955) · Experimental Biology and Medicine · doi:10.3181/00379727-90-21985 · Cited by 2,429
Fundamentals of Clinical Trials
Friedman, L. M., Furberg, C. D., DeMets, D. L., Reboussin, D. M., & Granger, C. B. (2015) · doi:10.1007/978-3-319-18539-2 · Cited by 2,237
Interleukin-1 and Its Biologically Related Cytokines
Dinarello, C. A. (1989) · Advances in Immunology · doi:10.1016/s0065-2776(08)60642-2 · Cited by 1,151
IL-6 is produced by osteoblasts and induces bone resorption.
Ishimi, Y., Miyaura, C., Jin, C. H., Akatsu, T., Abe, E., Nakamura, Y., Yamaguchi, A., Yoshiki, S., Matsuda, T., Hirano, T., et al. (1990) · The Journal of Immunology · doi:10.4049/jimmunol.145.10.3297 · Cited by 1,128
Agins, H. J., Alcock, N. W., Bansal, M., Salvati, E. A., Wilson, P. D., Pellicci, P. M., & Bullough, P. G. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870030-00005 · Cited by 496
VAES, G. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198806000-00033 · Cited by 404
Macrophages stimulate bone resorption when they phagocytose particles
Murray, D., & Rushton, N. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246303 · Cited by 402
Size of metallic and polyethylene debris particles in failed cemented total hip replacements
Lee, J., Salvati, E., Betts, F., DiCarlo, E., Doty, S., & Bullough, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b3.1587882 · Cited by 176
Interleukin‐6 production by human gingival fibroblasts
Bartold, P. M., & Haynes, D. R. (1991) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1991.tb02072.x · Cited by 173
Self-citationTissue response in relation to type of wear particles around failed hip arthroplasties
Howie, D. W. (1990) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(08)80093-9 · Cited by 150
Self-citation
Cited by
Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering
Brydone, A. S., Meek, D., & Maclaine, S. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim770 · Cited by 456
Widespread dissemination of metal debris from implants
Case, C., Langkamer, V., James, C., Palmer, M., Kemp, A., Heap, P., & Solomon, L. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b5.8083255 · Cited by 444
Biomaterials for Bone Regenerative Engineering
Yu, X., Tang, X., Gohil, S. V., & Laurencin, C. T. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400760 · Cited by 418
General review of titanium toxicity
Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M. (2019) · International Journal of Implant Dentistry · doi:10.1186/s40729-019-0162-x · Cited by 404
Jacobs, J. J., Roebuck, K. A., Archibeck, M., Hallab, N. J., & Glant, T. T. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200112000-00008 · Cited by 367
Degasne, I., Baslé, M. F., Demais, V., Huré, G., Lesourd, M., Grolleau, B., Mercier, L., & Chappard, D. (1999) · Calcified Tissue International · doi:10.1007/s002239900640 · Cited by 328
The Biology of Aseptic Osteolysis
Holt, G., Murnaghan, C., Reilly, J., & Meek, R. M. D. (2007) · Clinical Orthopaedics & Related Research · doi:10.1097/blo.0b013e31804b4147 · Cited by 319
Biomechanical behaviours of the bone–implant interface: a review
Gao, X., Fraulob, M., & Haïat, G. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0259 · Cited by 263
Human monocyte response to particulate biomaterials generated in vivo and in vitro
Shanbhag, A. S., Jacobs, J. J., Black, J., Galante, J. O., & Glant, T. T. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130520 · Cited by 252
Effects of thirty elements on bone metabolism
Dermience, M., Lognay, G., Mathieu, F., & Goyens, P. (2015) · Journal of Trace Elements in Medicine and Biology · doi:10.1016/j.jtemb.2015.06.005 · Cited by 249
Inhibition of Wear Debris Mediated Osteolysis in a Canine Total Hip Arthroplasty Model
Shanbhag, A. S., Hasselman, C. T., & Rubash, H. E. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199711000-00005 · Cited by 216
Spinal Implant Debris-Induced Osteolysis
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J. (2003) · Spine · doi:10.1097/00007632-200310151-00006 · Cited by 201
“For TJA these include the cytokines IL-1, IL-6, and TNF- .(59,60) However, for spinal devices, limited investigations have thus far only identified TNF- as a locally elevated cytokine associated with peri-posterolateral arthrodesis.”
BackgroundBordji, K., Jouzeau, J. Y., Mainard, D., Payan, E., Netter, P., Rie, K. T., Stucky, T., & Hage-Ali, M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)83289-3 · Cited by 195
Measurement and removal of adherent endotoxin from titanium particles and implant surfaces
Ragab, A. A., Van De Motter, R., Lavish, S. A., Goldberg, V. M., Ninomiya, J. T., Carlin, C. R., & Greenfield, E. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170603 · Cited by 191
“For example, individual studies have reported that cobalt chrome (9), commercially pure titanium (30), titanium alloy (22,45,46), polymethylniet hacrylate (18), and ultra high molecular weight polyethylene (21) are all the most potent type of particle.”
BackgroundFleury, C., Petit, A., Mwale, F., Antoniou, J., Zukor, D. J., Tabrizian, M., & Huk, O. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.035 · Cited by 163
Alrabeah, G. O., Brett, P., Knowles, J. C., & Petridis, H. (2017) · Journal of Dentistry · doi:10.1016/j.jdent.2017.08.002 · Cited by 85
Neale, S. D., & Athanasou, N. A. (1999) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679909000980 · Cited by 62
Metadata
- Authors
- Haynes, D. R., Rogers, S. D., Hay, S., Pearcy, M. J., & Howie, D. W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1993-06
- Volume
- 75
- Issue
- 6
- Pages
- 825-834
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2226891106
- Cited by
- 425
- References
- 20
- FWCI
- 21.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.