The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans
Abstract
BACKGROUND: Computerized tomographic scans are routinely obtained to evaluate a number of musculoskeletal conditions. However, since computerized tomographic scans expose patients to the greatest amounts of radiation of all imaging modalities, the physician must be cognizant of the effective doses of radiation that are administered. This investigation was performed to quantify the effective doses of computerized tomographic scans that are performed for various musculoskeletal applications. METHODS: The digital imaging archive of a single institution was retrospectively reviewed to identify helical computerized tomographic scans that were completed to visualize the extremities or spine. Imaging parameters were recorded for each examination, and dosimetry calculator software was used to calculate the effective dose values according to a modified protocol derived from publication SR250 of the National Radiological Protection Board of the United Kingdom. Computerized tomographic scans of the chest, abdomen, and pelvis were also collected, and the effective doses were compared with those reported by prior groups in order to validate the results of the current study. RESULTS: The mean effective doses for computerized tomographic scans of the chest, abdomen, and pelvis (5.27, 4.95, and 4.85 mSv, respectively) were consistent with those of previous investigations. The highest mean effective doses were recorded for studies evaluating the spine (4.36, 17.99, and 19.15 mSv for the cervical, thoracic, and lumbar spines, respectively). In the upper extremity, the effective dose of a computerized tomographic scan of the shoulder (2.06 mSv) was higher than those of the elbow (0.14 mSv) and wrist (0.03 mSv). Similarly, the effective dose of a hip scan (3.09 mSv) was significantly higher than those observed with knee (0.16 mSv) and ankle (0.07 mSv) scans. CONCLUSIONS: Computerized tomographic scans of the axial and appendicular skeleton are associated with substantially elevated radiation exposures, but the effective dose declines substantially for anatomic structures that are further away from the torso.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
Brenner, D. J., Doll, R., Goodhead, D. T., Hall, E. J., Land, C. E., Little, J. B., Lubin, J. H., Preston, D. L., Preston, R. J., Puskin, J. S., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2235592100 · Cited by 1,765
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Preston, D. L., Shimizu, Y., Pierce, D. A., Suyama, A., & Mabuchi, K. (2003) · Radiation Research · doi:10.1667/rr3049 · Cited by 1,172
Radiation-Related Cancer Risks at Low Doses among Atomic Bomb Survivors
Pierce, D. A., & Preston, D. L. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0178:rrcral]2.0.co;2 · Cited by 757
Estimated Radiation Risks Potentially Associated with Full-Body CT Screening
Brenner, D. J., & Elliston, C. D. (2004) · Radiology · doi:10.1148/radiol.2323031095 · Cited by 685
Cardis, E., Vrijheid, M., Blettner, M., Gilbert, E., Hakama, M., Hill, C., Howe, G., Kaldor, J., Muirhead, C. R., Schubauer-Berigan, M., et al. (2007) · Radiation Research · doi:10.1667/rr0553.1 · Cited by 679
CT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries
Cardis, E., Vrijheid, M., Blettner, M., Gilbert, E., Hakama, M., Hill, C., Howe, G., Kaldor, J., Muirhead, C. R., Schubauer-Berigan, M., et al. (2005) · BMJ · doi:10.1136/bmj.38499.599861.e0 · Cited by 608
Cardis, E., Gilbert, E. S., Carpenter, L., Howe, G., Kato, I., Armstrong, B. K., Beral, V., Cowper, G., Douglas, A., Fix, J., et al. (1995) · Radiation Research · doi:10.2307/3579020 · Cited by 522
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Chauhan, S. K., Clark, G. W., Lloyd, S., Scott, R. G., Breidahl, W., & Sikorski, J. M. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b6.15456 · Cited by 272
Rothenberg, L. N., & Pentlow, K. S. (1992) · RadioGraphics · doi:10.1148/radiographics.12.6.1439023 · Cited by 192
Dosimetry for optimisation of patient protection in computed tomography
Jessen, K. A., Shrimpton, P. C., Geleijns, J., Panzer, W., & Tosi, G. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00024-4 · Cited by 187
Radiation Effective Doses to Patients Undergoing Abdominal CT Examinations
Ware, D. E., Huda, W., Mergo, P. J., & Litwiller, A. L. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr05645 · Cited by 153
Effective doses to patients undergoing thoracic computed tomography examinations
Huda, W., Scalzetti, E. M., & Roskopf, M. L. (2000) · Medical Physics · doi:10.1118/1.598949 · Cited by 144
Ngaile, J. E., Msaki, P., & Kazema, R. (2006) · Journal of Radiological Protection · doi:10.1088/0952-4746/26/2/006 · Cited by 37
Papadimitriou, D., Perris, A., Manetou, A., Molfetas, M., Panagiotakis, N., Lyra-Georgosopoulou, M., Hourdakis, K., Κόττου, Σ., Tosi, G., Origgi, D., et al. (2003) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006162 · Cited by 32
Pierce, D. A., & Væth, M. (2000) · PubMed · Cited by 15
[Radiation exposure and computed tomography].
Trigaux, J. P., & Lacrosse, M. (1999) · PubMed · Cited by 10
Metadata
- Authors
- Biswas, D., Bible, J. E., Bohan, M., Simpson, A. K., Whang, P. G., & Grauer, J. N.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2009-08
- Volume
- 91
- Issue
- 8
- Pages
- 1882-1889
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2154807527
- Cited by
- 441
- References
- 22
- FWCI
- 13.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.