Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction
Open accessThe DOI matches its Crossref record; 97 of the 97 references it cites were found in a registry or an index; 34 of the 105 sources its claims cite were checked for support.
Abstract
Computed tomography (CT) contributes substantially to medical radiation exposure, making diagnostic reference levels (DRLs) essential for dose optimization and patient protection.
Overview
CoChat Summary
TL;DR
This is a structured narrative review of CT diagnostic reference levels (DRLs) worldwide, with focused attention to Jordan. The paper argues that Jordan has useful local dose data but still lacks a unified national CT DRL framework, and it recommends standardized reporting, auditing, and periodic revision.
Key findings
- The review found marked cross-country variation in CT DRL methodology, updating cycles, and regulatory integration.
- In the UK, the current adult head CT DRL is reported as 47 mGy CTDIvol and 790 mGy·cm DLP, based on a nationwide study of more than 47,000 CT examinations across 182 scanners.
- In Uganda, a national adult head CT DRL was reported as 56.02 mGy CTDIvol and 1260.3 mGy·cm DLP from a multicenter survey across 13 institutions.
- In Jordan, one cited study of more than 2,000 CT scans (2021–2022) proposed adult head CT DRLs of 65.1 mGy CTDIvol and 945 mGy·cm DLP; another Jordan study of 228 cardiac CT examinations from seven hospitals reported 47.7 mGy CTDIvol and 1,035 mGy·cm DLP, with more than fivefold variation across institutions.
Methods
- The paper is a structured narrative review of CT DRLs worldwide, with a focused appraisal of evidence from Jordan.
- Literature and guidance were searched in PubMed, Scopus, Web of Science, and Google Scholar, plus reference lists; search terms included CT, DRL, CTDIvol, DLP, SSDE, radiation dose, dose optimization, and Jordan.
- Included sources addressed adult or pediatric CT DRLs, local/national DRL surveys, CT dose metrics, or international guidance; findings were synthesized narratively.
Limitations
- The paper does not report a formal systematic-review quality assessment or meta-analysis; this is evident from the stated structured narrative review design.
- The review relies on the available published studies and guidance documents and explicitly notes evidence gaps and fragmented practices in Jordan, indicating incomplete national data.
- The text makes evident that some cited country comparisons are not directly comparable because DRLs vary by methodology, patient selection, and update cycle; this is described in the paper rather than presented as a study limitation.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
26 Valid · 7 Not valid · 51 Not checked · 33 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“A national DRL of 56.02 mGy (CTDIvol) and 1260.3 mGy·cm (DLP) for adult head CT was established in Uganda through a multicenter survey done across 13 institutions in partnership with the IAEA.80,81”
§ Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction > Diagnostic Reference Levels (DRLs) > Role and Purpose of DRLs in Radiation Protection
What the sources say
- Partly supportedcites [80] Erem, 2022, BMC Medical Imaging sourceExperimental — accuracy not yet measured
The Results and Discussion report adult head CT values of 56.02 mGy CTDIvol and approximately 1260.3 mGy·cm DLP, and the Conclusion says national DRLs were determined. But Materials and methods (Participating institutions) says the survey recruited patients from seven facilities, not 13. The paper mentions IAEA guidance and an IAEA image-quality tool, but does not describe a partnership with the IAEA. (LLM, conf=0.92)
- Not matchedcites [81] Kiragga, 2023, Res Square
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This gap indicates not just discrepancies in patient demographics and equipment but also methodological disparities in data collecting and dosage analysis.116”
§ Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction > International DRL Guidelines and Practices > Comparison of DRL Implementation Across Countries
What the sources say
- Partly supportedcites [116] Tan, 2023, Radiography sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) says CT-dose variation across institutions can reflect scanner characteristics, scan protocols, parameters and patient profiles. But this single-site study compares its values with EU and Irish DRLs, not UK and Japanese DRLs; it does not attribute a UK–Japan gap to differences in data collection or dose analysis. (LLM, conf=0.79)
hedgedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“For adult head CT, the DRLs are approximately 77 mGy CTDIvol and 1,350 mGy·cm DLP, contingent upon the equipment and scanning parameters utilized.112”
§ Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction > International DRL Guidelines and Practices > ICRP Guidelines and International Support for DRL Implementation
What the sources say
- Supportedcites [112] Kanda, 2021, Jpn J Radiol source
Table 4 in “Validation of Japan DRLs 2020” lists the Japan 2020 DRLs for routine brain CT in adults as 77 mGy CTDIvol and 1,350 mGy·cm DLP. The table specifies a standard adult body weight of 50–70 kg. (LLM, conf=0.93)
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Human resource constraints provide a substantial obstacle, notably a deficiency of qualified professionals, including medical physicists and radiologists.”
§ Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction > Challenges in Implementing DRLs in Low- and Middle-Income Countries (LMICs) > Human Resource Limitations in LMICs
What the sources say
- Partly supportedcites [120] Bezuidenhout, 2018, Global Bioethics sourceExperimental — accuracy not yet measured
The “Data sharing and LMICs” section identifies a paucity of qualified technical support as one obstacle to researchers’ data-sharing activities. It does not identify shortages of medical physicists or radiologists; the professional shortage specified in the claim is unsupported. (LLM, conf=0.83)
- Could not verifycites [121] Rowe, 2018, The Lancet. Global Health sourceExperimental — accuracy not yet measured
The Introduction discusses inadequate health-care provider performance in low-income and middle-income countries and includes availability within its definition of performance. It does not report a shortage of qualified professionals or identify medical physicists or radiologists; searches for those professions and for workforce shortages found no supporting passage. (LLM, conf=0.75)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In numerous low- and middle-income countries, healthcare practitioners sometimes have excessive clinical responsibilities, resulting in minimal capacity for data collecting, analysis, or research dissemination.120,121”
§ Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction > Challenges in Implementing DRLs in Low- and Middle-Income Countries (LMICs) > Human Resource Limitations in LMICs
What the sources say
- Partly supportedcites [120] Bezuidenhout, 2018, Global Bioethics sourceExperimental — accuracy not yet measured
The Introduction and “Data sharing and LMICs” section describe barriers to LMIC researchers’ data sharing, including high teaching loads and limited time to work online (page numbers unavailable). They do not say that healthcare practitioners’ clinical responsibilities leave minimal capacity for data collection, analysis, or research dissemination; the workload described is teaching, not clinical care. (LLM, conf=0.79)
- Could not verifycites [121] Rowe, 2018, The Lancet. Global Health sourceExperimental — accuracy not yet measured
The Discussion recommends using routinely collected data to reduce the time and cost of studies, but does not say that excessive clinical responsibilities leave practitioners little capacity for data collection, analysis, or dissemination. Searches for clinical workload, research time, and dissemination found no passage addressing that causal claim. The indexed passages provide section labels but no page numbers. (LLM, conf=0.76)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
20 more claims · 3 with their cited sources checked
Create a free account to see all 117 claims and to verify the 6 references still open.
- Probably not a substantial claim. 66
- It may state two separate claims as one. 57
- Borderline: one of the tests for a substantial claim is unclear. 1
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction > Diagnostic Reference Levels (DRLs) > Parameters Used in DRLs
“The DLP, expressed in mGy·cm, is determined by multiplying CTDIvol by the scan duration.”
§ Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction > Diagnostic Reference Levels (DRLs) > Parameters Used in DRLs
“In CT, the two primary metrics recommended for DRLs are the volume-weighted computed tomography dose index (CTDIvol) and the dose-length product (DLP).85”
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080 · cited 2×
“20,21 Computed tomography is extensively utilized in the thorax to assess pulmonary embolism, pulmonary infections, and for oncological staging.”
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A. (2017) · Annals of the ICRP · doi:10.1177/0146645317717209 · Cited by 1,043 · cited 3×
“2,67,68 The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.”
Cancer risks following diagnostic and therapeutic radiation exposure in children
Kleinerman, R. A. (2006) · Pediatric Radiology · doi:10.1007/s00247-006-0191-5 · Cited by 585
Rowe, A. K., Rowe, S. Y., Peters, D. H., Holloway, K. A., Chalker, J., & Ross-Degnan, D. (2018) · The Lancet Global Health · doi:10.1016/s2214-109x(18)30398-x · Cited by 482 · cited 1×
“Motivated by global examples such as the UK’s audits, Japan’s tiered DRLs, and Saudi Arabia’s academic initiatives, Jordan can establish its own DRL framework by standardizing CTDIvol and DLP reporting across institutions.”
ICRP Publication 137: Occupational Intakes of Radionuclides: Part 3
Paquet, F., Bailey, M. R., Leggett, R. W., Lipsztein, J., Marsh, J., Fell, T. P., Smith, T., Nosske, D., Eckerman, K. F., Berkovski, V., et al. (2017) · Annals of the ICRP · doi:10.1177/0146645317734963 · Cited by 385
Projected Lifetime Cancer Risks From Current Computed Tomography Imaging
Smith-Bindman, R., Chu, P. W., Azman Firdaus, H., Stewart, C., Malekhedayat, M., Alber, S., Bolch, W. E., Mahendra, M., Berrington de González, A., & Miglioretti, D. L. (2025) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2025.0505 · Cited by 358 · cited 1×
“37–39 In Jordan, although national-level CT usage data is few, existing studies indicate a comparable rise.”
Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
Silva, A. C., Morse, B. G., Hara, A. K., Paden, R. G., Hongo, N., & Pavlicek, W. (2011) · RadioGraphics · doi:10.1148/rg.314105159 · Cited by 351
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335 · cited 1×
“53,54 This unequal contribution has generated much concern, especially as CT usage continues to rise in emergency, oncological, and pediatric contexts.”
How to improve access to medical imaging in low- and middle-income countries
Frija, G., Blažić, I., Frush, D. P., Hierath, M., Kawooya, M., Donoso-Bach, L., & Brkljačić, B. (2021) · eClinicalMedicine · doi:10.1016/j.eclinm.2021.101034 · Cited by 310 · cited 1×
“102,122”
Baumann, B. M., Chen, E. H., Mills, A. M., et al. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.10.018 · Cited by 138 · cited 1×
“53,54 This unequal contribution has generated much concern, especially as CT usage continues to rise in emergency, oncological, and pediatric contexts.”
Brady, S. L., & Kaufman, R. A. (2012) · Radiology · doi:10.1148/radiol.12120131 · Cited by 137 · cited 1×
“91 SSDE, originally introduced by the American Association of Physicists in Medicine (AAPM Report No. 204), 92 is increasingly utilized in pediatric imaging and adult body CT, where patient size markedly influences radiation absorption.”
Hidden concerns of sharing research data by low/middle-income country scientists
Bezuidenhout, L., & Chakauya, E. (2018) · Global Bioethics · doi:10.1080/11287462.2018.1441780 · Cited by 126 · cited 1×
“120,121 Despite the availability of data, publication efforts may be obstructed by institutional limitations or elevated rejection rates in peer-reviewed journals.”
Computed Tomography 2.0: New Detector Technology, AI, and Other Developments
Lell, M., & Kachelrieß, M. (2023) · Investigative Radiology · doi:10.1097/rli.0000000000000995 · Cited by 112
Dose reduction with iterative reconstruction: Optimization of CT protocols in clinical practice
Greffier, J., Macrì, F., Larbi, A., et al. (2015) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2015.02.007 · Cited by 98
Schwartz, F. R., Sodickson, A. D., Pickhardt, P. J., Sahani, D. V., Lev, M. H., & Gupta, R. (2025) · Radiology · doi:10.1148/radiol.240662 · Cited by 90
Emerging Techniques for Dose Optimization in Abdominal CT
Kaza, R. K., Platt, J. F., Goodsitt, M. M., Al-Hawary, M. M., Maturen, K. E., Wasnik, A. P., & Pandya, A. (2014) · Radiographics · doi:10.1148/rg.341135038 · Cited by 83 · cited 1×
“47,48 Miscentering the patient elevates surface dosage by more than 20% and compromises imaging quality.”
Mayo, J. R., & Thakur, Y. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9928 · Cited by 80
How to establish and use local diagnostic reference levels: an ESR EuroSafe Imaging expert statement
Damilakis, J., Frija, G., Brkljacic, B., Vano, E., Loose, R., Paulo, G., Brat, H., Tsapaki, V., & the European Society of Radiology (2023) · Insights into Imaging · doi:10.1186/s13244-023-01369-x · Cited by 76
Limitations of diagnostic reference level (DRL) and introduction of acceptable quality dose (AQD)
Rehani, M. M. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20140344 · Cited by 67
Bos, D., Yu, S., Luong, J., Chu, P., Wang, Y., Einstein, A. J., Starkey, J., Delman, B. N., Duong, P.-A. T., Das, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08266-1 · Cited by 64
Computed Tomography: Physical Principles and Recent Technical Advances
Seeram, E. (2010) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2010.04.001 · Cited by 63 · cited 1×
“44 Detector configuration and slice thickness similarly affect dosage efficiency; thinner slices enhance spatial resolution but also elevate noise levels and typically necessitate increased mAs.”
Sverzellati, N., Ryerson, C. J., Milanese, G., et al. (2021) · European Respiratory Journal · doi:10.1183/13993003.04188-2020 · Cited by 59 · cited 1×
“34,35 Nonetheless, this increase in utilization has prompted apprehensions regarding superfluous imaging.”
Developing diagnostic reference levels in Japan
Kanda, R., Akahane, M., Koba, Y., Chang, W., Akahane, K., Okuda, Y., & Hosono, M. (2021) · Japanese Journal of Radiology · doi:10.1007/s11604-020-01066-5 · Cited by 56 · cited 1×
“112 The Japanese method prioritizes institutional coordination and regular survey updates to ensure relevance.”
Cohen, E., Rodean, J., Diong, C. C., et al. (2019) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2019.1439 · Cited by 50 · cited 1×
“36 In the mid-1990s, computed tomography constituted merely 4% of imaging operations yet https://doi.org/10.2147/DHPS.”
InfluentialDetermination of the weighted CT dose index in modern multi-detector CT scanners
Perisinakis, K., Damilakis, J., Tzedakis, A., Papadakis, A., Theocharopoulos, N., & Gourtsoyiannis, N. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/010 · Cited by 47
Roch, P., Célier, D., Dessaud, C., Étard, C., & Rehani, M. M. (2019) · European Radiology · doi:10.1007/s00330-019-06422-2 · Cited by 47 · cited 1×
“2,67,68 The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.”
Implementation of DRLs in the UK
Wall, B. F. (2005) · Radiation Protection Dosimetry · doi:10.1093/rpd/nch505 · Cited by 46
Järvinen, H., Vassileva, J., Samei, E., Wallace, A., Vano, E., & Rehani, M. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.3.031214 · Cited by 45
Pathophysiology and therapy of systemic vasculitides
Ralli, M., Campo, F., Angeletti, D., Minni, A., Artico, M., Greco, A., Polimeni, A., & VINCENTIIS, M. D. (2020) · EXCLI journal · doi:10.17179/excli2020-1512 · Cited by 44 · cited 1×
“26,27 In Jordan, similar to numerous nations, computed tomography is progressively employed in emergency rooms and oncology treatments, mirroring global trends in high-dependency medical care.”
Franck, C., Vandevoorde, C., Goethals, I., Smeets, P., Achten, E., Verstraete, K., Thierens, H., & Bacher, K. (2016) · European Radiology · doi:10.1007/s00330-015-4091-7 · Cited by 43 · cited 1×
“94 Weighted CT Dose Index (CTDIw) Historically, the CTDIw was utilized before the prevalent usage of CTDIvol.”
Radiation Protection in Diagnostic Radiology
Shannoun, F., Blettner, M., Schmidberger, H., & Zeeb, H. (2008) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2008.0041 · Cited by 42 · cited 1×
“52 While individual CT scans present a very minimal risk, their cumulative effect on population radiation exposure is significant.”
Current status of low dose multi-detector CT in the urinary tract
Sung, M. K. (2011) · World Journal of Radiology · doi:10.4329/wjr.v3.i11.256 · Cited by 37 · cited 1×
“20,29,30 The rapid acquisition and elevated diagnostic yield of CT have resulted in its extensive utilization, especially in emergency contexts when prompt decision-making is essential.”
Dynamic Hepatocellular Carcinoma Model Within a Liver Phantom for Multimodality Imaging
Ahmad, M. S., Suardi, N., Shukri, A., et al. (2020) · European Journal of Radiology Open · doi:10.1016/j.ejro.2020.100257 · Cited by 37
Self-citationOptimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging
154, I. P. (2023) · Annals of the ICRP · doi:10.1177/01466453231210646 · Cited by 37 · cited 3×
“70”
Harrison, J. D., Haylock, R., Jansen, J. T. M., Zhang, W., & Wakeford, R. (2023) · Journal of Radiological Protection · doi:10.1088/1361-6498/acbda7 · Cited by 35 · cited 1×
“41,42 Tube current (mA) and exposure duration, typically denoted as mAs, as the most significant exposure parameters.”
Garba, I., Zarb, F. L., McEntee, M. F., & Fabri, S. G. (2020) · Radiography · doi:10.1016/j.radi.2020.08.011 · Cited by 34
Radiation Doses in Cardiovascular Computed Tomography
Kędzierski, B., Macek, P., Dziadkowiec-Macek, B., Truszkiewicz, K., Poręba, R., & Gać, P. (2023) · Life · doi:10.3390/life13040990 · Cited by 33 · cited 1×
“88 While CTDIvol is not a direct indicator of the radiation received by the patient or tailored to specific anatomy, it is nonetheless a crucial comparison parameter among scanners and procedures.”
Larson, D. B. (2014) · Pediatric Radiology · doi:10.1007/s00247-014-3077-y · Cited by 31
National diagnostic reference levels: What they are, why we need them and what’s next
Thomas, P. (2022) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.13375 · Cited by 27 · cited 1×
“63,64 If median dosages for conventional procedures consistently surpass the DRL, a review must be conducted to evaluate the necessity for optimization, ensuring diagnostic quality is not compromised.”
Rosenstein, M. (2008) · Health Physics · doi:10.1097/01.hp.0000326331.35187.63 · Cited by 26
Erem, G., Ameda, F., Otike, C., Olwit, W., Mubuuke, A. G., Schandorf, C., Kisolo, A., & Kawooya, M. G. (2022) · BMC Medical Imaging · doi:10.1186/s12880-022-00838-x · Cited by 26 · cited 1×
“80,81 A 2024 systematic analysis from Saudi Arabia revealed CTDIvol values in the pediatric population ranging from 11.7 to 79.9 mGy, contingent upon age group and facility, underscoring the critical necessity for standardized DRLs in children to mitigate avoidable exposure and establish best…”
InfluentialThe International Atomic Energy Agency (IAEA): An active role in the global fight against cancer
Rosenblatt, E., Zubizarreta, E., Wondergem, J., Fidarova, E., & Izewska, J. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.10.004 · Cited by 25
Diagnostic reference levels in low- and middle-income countries: early “ALARAm” bells?
Meyer, S., Groenewald, W. A., & Pitcher, R. D. (2017) · Acta Radiologica · doi:10.1177/0284185116658681 · Cited by 24 · cited 1×
“102,122”
Smith-Bindman, R., Chu, P., Wang, Y., Chung, R., Lopez-Solano, N., Einstein, A. J., Solberg, L., Cervantes, L. F., Nelson, T. R., Boswell, W., et al. (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.0064 · Cited by 23
Veljkovikj, I., Ilbawi, A. M., Roitberg, F., Luciani, S., Barango, P., Corbex, M., Dorji, G., Gunawardena, N., Johnson, S., Juric, A., et al. (2022) · The Lancet Oncology · doi:10.1016/s1470-2045(22)00387-4 · Cited by 23
Hendriks, B. M. F., Schnerr, R. S., Milanese, G., et al. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2017.0779 · Cited by 22
COVID-19 imaging: Diagnostic approaches, challenges, and evolving advances
Pezzutti, D. L., Wadhwa, V., & Makary, M. S. (2021) · World Journal of Radiology · doi:10.4329/wjr.v13.i6.171 · Cited by 22 · cited 1×
“34,35 Nonetheless, this increase in utilization has prompted apprehensions regarding superfluous imaging.”
Establishment of diagnostic reference levels in cardiac computed tomography
Rawashdeh, M., Saade, C., Zaitoun, M., Abdelrahman, M., Brennan, P., Alewaidat, H., & McEntee, M. F. (2019) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12711 · Cited by 21 · cited 1×
“10 In a distinct study, Rawashdeh et al (2019) evaluated 228 cardiac CT examinations from seven hospitals in Jordan.”
Faj, D., Edyvean, S., Lajunen, A., Katukhov, A., & Vassileva, J. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.102565 · Cited by 21
The work programme of EURADOS on internal and external dosimetry
Rühm, W., Bottollier-Depois, J. F., Gilvin, P., Harrison, R., Knežević, Ž., Lopez, M. A., Tanner, R., Vargas, A., & Woda, C. (2018) · Annals of the ICRP · doi:10.1177/0146645318756224 · Cited by 19
Grunz, J., Jordan, M. C., Schmitt, R. R., Luetkens, K. S., Huflage, H., Meffert, R. H., Bley, T. A., & Kunz, A. S. (2022) · Academic Radiology · doi:10.1016/j.acra.2022.08.030 · Cited by 19
Abdel-Wahab, M., Lahoupe, B., Polo, A., Zubizarreta, E., Adnan, R. R., Johnston, P., Juric, A., Haffar, F. E., Andre, M., & Meghzifene, A. (2017) · The Lancet Oncology · doi:10.1016/s1470-2045(17)30372-8 · Cited by 18
(2020) · Europe PMC (PubMed Central) · doi:10.22038/aojnmb.2019.40863.1276 · Cited by 18 · cited 1×
“The establishment of DRLs relies on standardized, measurable dose parameters that provide uniform comparison across clinical settings and patient demographics.”
A look at radiation detectors and their applications in medical imaging
Usanase, N., Uzun, B., Ozsahin, D. U., & Özşahin, İ. (2023) · Japanese Journal of Radiology · doi:10.1007/s11604-023-01486-z · Cited by 18 · cited 1×
“45,46 Image reconstruction techniques are essential for dose optimization.”
Reducing Radiation, Revising Reference Levels
Miller, D. L., Vano, E., & Rehani, M. M. (2015) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2014.07.012 · Cited by 17
Oglat, A. A., Alshipli, M., Sayah, M. A., et al. (2021) · The Journal of Adhesion · doi:10.1080/00218464.2021.1878890 · Cited by 17
Self-citationJasieniak, J., Kuchcińska, A., Podgórska, J., & Cieszanowski, A. (2023) · Polish Journal of Radiology · doi:10.5114/pjr.2023.124376 · Cited by 17
Noferini, L., Fulcheri, C., Taddeucci, A., Bartolini, M., & Gori, C. (2014) · Radiological Physics and Technology · doi:10.1007/s12194-014-0265-2 · Cited by 16
Simplified size adjusted dose reference levels for adult CT examinations: A regional study
Moghadam, N., Lecomte, R., Mercure, S., Rehani, M. M., & Nassiri, M. A. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109861 · Cited by 16 · cited 1×
“85 These parameters constitute the foundation of national and international dose audits owing to their practicality, repeatability, and accessibility from practically all contemporary CT scanners.”
Radaideh, K., Al-Radaideh, A., Ramli, R. M., Saleh, A., & Alshayeb, R. (2023) · Polish Journal of Medical Physics and Engineering · doi:10.2478/pjmpe-2023-0003 · Cited by 16 · cited 2×
“9,10 The review aims to enhance radiation protection standards in Jordan and promote the advancement of safe imaging procedures by examining commonalities, discrepancies, and opportunities for improvement.”
Alawneh, K. Z., Raffee, L. A., Oqlat, A. A., et al. (2021) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2021.102220 · Cited by 15
Self-citationTan, W. S., Foley, S., & Ryan, M. L. (2023) · Radiography · doi:10.1016/j.radi.2023.05.003 · Cited by 15
Clerkin, C., Brennan, S., & Mullaney, L. M. (2018) · Reports of Practical Oncology & Radiotherapy · doi:10.1016/j.rpor.2018.07.012 · Cited by 14 · cited 1×
“63,64 If median dosages for conventional procedures consistently surpass the DRL, a review must be conducted to evaluate the necessity for optimization, ensuring diagnostic quality is not compromised.”
Rabus, H., Gómez-Ros, J. M., Villagrasa, C., Eakins, J., Vrba, T., Blideanu, V, Zankl, M., Tanner, R., Struelens, L., Brkić, H., et al. (2021) · Journal of Radiological Protection · doi:10.1088/1361-6498/abd914 · Cited by 13
Anim-Sampong, S., Antwi, W. K., Botwe, B. O., et al. (2016) · Safety in Health · doi:10.1186/s40886-016-0019-4 · Cited by 12 · cited 1×
“87 It is obtained from standardized phantom measurements conducted under uniform acquisition conditions.”
Ziade, N., Arayssi, T., Elzorkany, B., Daher, A., Karam, G. A., Jbara, M. A., Aiko, A., Alam, E., Emadi, S. A., Mashaleh, M. A., et al. (2021) · Mediterranean Journal of Rheumatology · doi:10.31138/mjr.32.1.66 · Cited by 12 · cited 1×
“28”
Rovera, G., Grimaldi, S., Oderda, M., et al. (2023) · Diagnostics · doi:10.3390/diagnostics13183013 · Cited by 12 · cited 1×
“26,27 In Jordan, similar to numerous nations, computed tomography is progressively employed in emergency rooms and oncology treatments, mirroring global trends in high-dependency medical care.”
Terahertz-Based IRS-Assisted Secure Symbiotic Radio Communication: A DRL Approach
Shahwar, M., Ahmed, M., Hussain, T., Ahmad, S., Ullah Khan, W., Sheraz, M., & Chee Chuah, T. (2025) · IEEE Access · doi:10.1109/access.2025.3539088 · Cited by 11 · cited 1×
“113”
Al-Horani, Q., Al‐Ibraheem, A., Rawashdeh, M. A., Alkhybari, E. M., Sabarudin, A., Latiff, R. A., & Mohamad, M. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e30030 · Cited by 10 · cited 1×
“84”
Yaghoobpoor, S., Fathi, M., Taher, H. J., et al. (2024) · Emergency Radiology · doi:10.1007/s10140-024-02249-7 · Cited by 10
Optimization of CT radiation dose: Insight into DLP and CTDI
Arfat, M., Haq, A., Beg, T., & Jaleel, G. (2024) · Future Health · doi:10.25259/fh_45_2024 · Cited by 10 · cited 2×
“84”
InfluentialTHE APPLICATION OF DIAGNOSTIC REFERENCE LEVELS FOR OPTIMISATION OF X-RAY IMAGING IN THE UK
Martin, C. J. (2016) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv433 · Cited by 8
Establishing and monitoring DRLS
Damilakis, J. E. (2016) · Physica Medica · doi:10.1016/j.ejmp.2016.07.296 · Cited by 8 · cited 2×
“2,67,68 The ICRP and IAEA offer guidance on the application of DRLs; however, the obligation to establish and revise DRLs rests with national authorities, including health ministries and professional radiology organizations.”
O’Hora, L., Neville, N., Tuffy, J., Craig, A., O’Brien, K., Sugrue, K., McGarry, M., Duggan, B., & Egan, S. (2023) · European Radiology · doi:10.1007/s00330-023-09992-4 · Cited by 8 · cited 1×
“69 DRLs are often articulated by modality-specific dosage measurements.”
Redefining Radiation Metrics: Evaluating Actual Doses in Computed Tomography Scans
Sabiniewicz-Ziajka, D., Szarmach, A., Grzywińska, M., Gać, P., & Piskunowicz, M. (2024) · Biomedicines · doi:10.3390/biomedicines12030600 · Cited by 8 · cited 1×
“89 The DLP, expressed in mGy·cm, is determined by multiplying CTDIvol by the scan duration.”
Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
Bouchareb, Y., Al-Maimani, A., Al-Balushi, A.-Y., Al-Kalbani, M., Al-Maskari, H., Al-Dhuhli, H., & Al-Kindi, F. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad225 · Cited by 7 · cited 1×
“79 A national DRL of 56.02 mGy (CTDIvol) and 1260.3 mGy·cm (DLP) for adult head CT was established in Uganda through a multicenter survey done across 13 institutions in partnership with the IAEA.”
InfluentialAlhujaili, S. F., Alshabibi, A. S., Alafer, F., Alrowaili, Z., Salah, H., Sulieman, A., Subahi, M., Al-Raddadi, K., & Abuzaid, M. (2024) · Diagnostics · doi:10.3390/diagnostics14242882 · Cited by 7
Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review
Alzyoud, K., Al-Murshedi, S., & England, A. (2024) · Health Physics · doi:10.1097/hp.0000000000001778 · Cited by 6 · cited 1×
“9,10 The review aims to enhance radiation protection standards in Jordan and promote the advancement of safe imaging procedures by examining commonalities, discrepancies, and opportunities for improvement.”
Alhorani, Q., Alkhybari, E., Rawashdeh, M., Sabarudin, A., Latiff, R. A., Al-Ibraheem, A., & Mohamad, M. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad2c62 · Cited by 6
Alnawafleh, T. M., Radzi, Y. M., Alshipli, M., et al. (2024) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/0115734056309829240909095801 · Cited by 6 · cited 1×
“18 The principal benefit of CT compared to traditional radiography is its capacity to provide cross-sectional images, thereby eliminating anatomical superimposition.”
Self-citationAge-specific DRLs for pediatric brain CT: A review for exploring the practices in Saudi Arabia
Aljuaid, L. M., Althobaiti, S. F., Althobaiti, A. A., Alsufyani, A. H., Alotaibi, M. H., Elkhader, B. A., Osman, H., Althoibe, M. M., Raafat, B. M., Dahlawi, H. A., et al. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2025.111664 · Cited by 6 · cited 1×
“114,115”
Aloufi, K. M., Gameraddin, M., Alhazmi, F. H., Almazroui, I. S., Osman, H., & Khandaker, M. U. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2024.111583 · Cited by 5 · cited 1×
“114,115”
Establishing local diagnostic reference levels for adult whole-body PET/CT in Malaysia
Said, A. A., Rahman, A. A., Halim, F. N. B. A., Albadarneh, L., Oglat, A. A., Saleh, H. H., Shloul, W., & Alshloul, Y. (2025) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaf053 · Cited by 5
Self-citationWen, X., Ou, T., Zeng, N., Li, X., Luo, A., Xu, X., Li, W., & Du, T. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108989 · Cited by 4
Al Ewaidat, H., Balawi, S., Bataineh, Z., Al‐Dwairi, A., Al‐Khalily, M., Azez, K. A., & Almakhadmeh, A. (2023) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22855 · Cited by 4
Oglat, A. A. (2024) · COVID · doi:10.3390/covid4070066 · Cited by 4
Self-citationGarba, I., & Engel-Hills, P. (2025) · Radiography · doi:10.1016/j.radi.2024.09.058 · Cited by 4 · cited 3×
“5,73,74 Both prospective and retrospective data may be utilized, typically obtained from Picture Archiving and Communication Systems (PACS), Radiology Information Systems (RIS), dosage monitoring software, or organized manual surveys.”
Improvements in radiation therapy services in Myanmar: 2012–2020
Opie, C., & Shwe, K. M. (2021) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.13188 · Cited by 3
Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks
Rawashdeh, M., Bani Yaseen, A.-B., McEntee, M., England, A., Kumar, P., & Saade, C. (2024) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-230276 · Cited by 3
Alenazi, K., Alahmad, H., Algamdi, S., Alhailiy, A., Alkhybari, E., Alhulail, A., Fisal, N., & Albeshan, S. (2024) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2024.111690 · Cited by 3 · cited 1×
“82,83 See Figure 1.”
Optimization and image quality in CT studies: application of DRLs based on clinical indication
Picone, C., Porto, A., Fusco, R., Granata, C., Brunese, M. C., Granata, V., Ottaiano, A., Barretta, M., Caranci, F., Pecori, B., et al. (2025) · Discover Applied Sciences · doi:10.1007/s42452-025-07125-8 · Cited by 3 · cited 1×
“70,71 According to ICRP Publication 135, DRLs function as investigative thresholds rather than regulatory dose limits, aimed at identifying abnormally high radiation doses in standard diagnostic and interventional procedures.”
van Schoonhoven, M. T., Hayre, D. C. M., & England, D. A. (2021) · Journal of Medical Imaging and Radiation Sciences · doi:10.1016/j.jmir.2021.09.004 · Cited by 2
Factors Predicting CT Pulmonary Angiography Results in the Emergency Department
Rakuša, N., Sertić, Z., Prutki, M., et al. (2025) · Diagnostics · doi:10.3390/diagnostics15070827 · Cited by 2
Masoomi, M., Al-Kandari, L., Al-Shammeri, I., Elrahman, H., & Al-Shammeri, J. (2023) · BJR|Open · doi:10.1093/bjro/tzae032 · Cited by 1
Rasheed, R. M., & Rae, W. I. D. (2025) · Journal of Radiation Protection and Research · doi:10.14407/jrpr.2024.00178 · Cited by 1 · cited 1×
“17,72”
Ewaidat, H. A., Oglat, A. A., Almakhadmeh, A., Aljarrah, T., Eltahir, M. A., Al-Masaid, K. A. A., E’layan, A. W. Y., Alawaqla, M. Q., Hamarneh, I. I., Allouh, M. M., et al. (2025) · PubMed Central · doi:10.2147/jmdh.s514510 · Cited by 1
Self-citation
Research works printed but not linked: 25
- 2018, Radiation Protection No. 185 European Guidelines on Diagnostic Reference Levels for Paediatric Imaging
- Oglat, 2022, Jordan J Biological Sci, 15, 2
- Johnson, 2009, Radiol, 39, 1059
- Murugan, 2025, Am J Psychiatr Rehabil, 28, 108
- 2012, Radiation Dose From Multidetector CT
- 2025, A Clinical Lens on Pediatric Engineering: Pioneering Science and Technology for Cutting-Edge Patient Care
- Hussain, 2025, J Shoulder Elbow Surg, 2025, 1
- 2022, Healthcare
- Najjar, 2023, 15, e41623
- Sohu, 2022, World J Radiol, 16, 47
- Malone J, Holmberg O, Simeonov G. Justification of medical exposure in diagnostic imaging. In Proceedings of International Workshop by the International Atomic Energy Agency (IAEA). 2009.
- Dudhe, 2024, Cureus, 16, 1
- 2018, Dose, Benefit, and Risk in Medical Imaging
- 2013, Radiological Safety and Quality: Paradigms in Leadership and Innovation
- 2015, Optimisation and Establishment of Diagnostic Reference Levels in Paediatric Plain Radiography
- 2016, Future Developments and Trends in Use of Picture Archiving and Communication Systems
- 2019, Digital Radiography: Physical Principles and Quality Control
- Kiragga, 2023, Res Square, 2683913
- Alenazi, 2025, J Radiat Res Appl Sci, 18, 101371
- Alkhidir, 2019, IOSR J Dent Med Sci, 18, 81
- 2022, Setting up a Cancer Centre: A WHO-IAEA Framework
- Bottollier-Depois, 2020, EURADOS Report, 4, 1
- 2015, US National Diagnostic Reference Levels: Closing the Gap
- 2025, The Sixth Asian Radiology Summit the Diagnostic Reference Levels (Drls): “asia Safe”—current Situation in Asian Countries
- Masoomi, 2020, medRxiv, 2020, 20198176
Cited by
Ababneh, E., & Alfwares, A. A. (2026) · Health Research in Africa · doi:10.67260/hra.v4i10.7950
“Nonetheless, substantial variation in radiation dose values persists across medical facilities, attributable to factors such as scanner technology, operator experience, and imaging protocols [8 – 10].”
Metadata
- Authors
- Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W.
- Affiliations
- Hashemite University (JO)
- Al-Hussein Bin Talal University (JO)
- Liwa University (AE)
- Corresponding author
- Oglat, Ammar
- Venue
- Drug, Healthcare and Patient Safety
- Publisher
- Informa UK Limited
- Published
- 2026-05
- Volume
- Volume 18
- Pages
- 1-16
- ISSN
- 1179-1365 (ISSN-L)
- PMC
- PMC13148269
- OpenAlex
- W7160054358
- Cited by
- 0
- References
- 97
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Drug Healthcare and Patient Safety (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by-nc)
- Dove Medical Press (Taylor and Francis Group) (submittedVersion, cc-by-nc)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- computed tomography, diagnostic reference levels, radiation dose reduction, patient radiation protection, CTDIvol, dose-length product, size-specific dose estimate, pediatric CT, inter-institutional variability, Jordan
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

