Abstract
Foot ulcers account for 15% of comorbidities associated with diabetes. Presently, no device allows the status of foot ulcers to be continuously monitored when patients are not hospitalized. In this study, we describe a temperature and a pH sensor capable of monitoring diabetic foot and venous leg ulcers developed in the frame of the seventh framework program European Union project SWAN-iCare (smart wearable and autonomous negative pressure device for wound monitoring and therapy). Temperature is measured by exploiting the variations in the electrical resistance of a nanocomposite consisting of multiwalled carbon nanotubes and poly(styrene-b-(ethylene- co -butylene)-b-styrene). The pH sensor used a graphene oxide (GO) layer that changes its electrical potential when pH changes. The temperature sensor has a sensitivity of ~85 Ω/°C in the range 25°C–50°C and a high repeatability (maximum standard deviation of 0.1% over seven repeated measurements). For a GO concentration of 4 mg/mL, the pH sensor has a sensitivity of ~42 mV/pH and high linearity (R 2 =0.99). Keywords: diabetic foot ulcer, wearable sensors, wound temperature, wound pH
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Long-term monitoring of body temperature by using flexible temperature sensors is convenient and can effectively prevent medical abnormalities such as foot ulcers.[227]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [227]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Diabetes Federation 2017
Carracher, A. M., Marathe, P. H., & Close, K. L. (2018) · Journal of Diabetes · doi:10.1111/1753-0407.12644 · Cited by 13,418
Carbon Nanotubes--the Route Toward Applications
Baughman, R. H., Zakhidov, A. A., & de Heer, W. A. (2002) · Science · doi:10.1126/science.1060928 · Cited by 10,267
The global burden of diabetic foot disease
Boulton, A. J., Vileikyte, L., Ragnarson-Tennvall, G., & Apelqvist, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67698-2 · Cited by 2,566
Biocompatibility of Graphene Oxide
Wang, K., Ruan, J., Song, H., Zhang, J., Wo, Y., Guo, S., & Cui, D. (2010) · Nanoscale Research Letters · doi:10.1007/s11671-010-9751-6 · Cited by 1,061
Prompers, L., Huijberts, M., Apelqvist, J., Jude, E., Piaggesi, A., Bakker, K., Edmonds, M., Holstein, P., Jirkovska, A., Mauricio, D., et al. (2007) · Diabetologia · doi:10.1007/s00125-006-0491-1 · Cited by 1,023
Self-citationPrompers, L., Schaper, N., Apelqvist, J., Edmonds, M., Jude, E., Mauricio, D., Uccioli, L., Urbancic, V., Bakker, K., Holstein, P., et al. (2008) · Diabetologia · doi:10.1007/s00125-008-0940-0 · Cited by 1,019
Self-citationBurden of Diabetic Foot Ulcers for Medicare and Private Insurers
Rice, J. B., Desai, U., Cummings, A. K. G., Birnbaum, H. G., Skornicki, M., & Parsons, N. B. (2014) · Diabetes Care · doi:10.2337/dc13-2176 · Cited by 624 · cited 1×
“In the United States, a substantial burden between $9 billion and $13 billion can be estimated for the health care system, summing the impact on private and public payers.(12) Infection in DF ulcers is a major risk factor leading to amputation,(10) and for this reason, the monitoring of the foot ulcers’ status may be…”
Shih, C.-J., Lin, S., Sharma, R., Strano, M. S., & Blankschtein, D. (2012) · Langmuir · doi:10.1021/la203607w · Cited by 605
Literature review on the management of diabetic foot ulcer
Yazdanpanah, L. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i1.37 · Cited by 596
Thermoplastic elastomers : a comprehensive review
Legge, N. R., Holden, G., & Schroeder, J. H. (1987) · Medical Entomology and Zoology · Cited by 501
Guest Editorial: are diabetes‐related wounds and amputations worse than cancer?
Armstrong, D. G., Wrobel, J., & Robbins, J. M. (2007) · International Wound Journal · doi:10.1111/j.1742-481x.2007.00392.x · Cited by 456
Skin Temperature Monitoring Reduces the Risk for Diabetic Foot Ulceration in High-risk Patients
Armstrong, D. G., Holtz-Neiderer, K., Wendel, C., Mohler, M. J., Kimbriel, H. R., & Lavery, L. A. (2007) · The American Journal of Medicine · doi:10.1016/j.amjmed.2007.06.028 · Cited by 437
What is the most effective way to reduce incidence of amputation in the diabetic foot?
Apelqvist, J., & Larsson, J. (2000) · Diabetes/Metabolism Research and Reviews · doi:10.1002/1520-7560(200009/10)16:1+<::aid-dmrr139>3.0.co;2-8 · Cited by 408
Home Monitoring of Foot Skin Temperatures to Prevent Ulceration
Lavery, L. A., Higgins, K. R., Lanctot, D. R., Constantinides, G. P., Zamorano, R. G., Armstrong, D. G., Athanasiou, K. A., & Agrawal, C. M. (2004) · Diabetes Care · doi:10.2337/diacare.27.11.2642 · Cited by 378
Cell and protein compatibility of parylene-C surfaces
Chang, T. Y., Yadav, V. G., De Leo, S., Mohedas, A., Rajalingam, B., Chen, C.-L., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A. (2007) · Langmuir · doi:10.1021/la7017049 · Cited by 320 · cited 1×
“the literature, although its effect on the shrinkage/expansion of the nanocomposite should be investigated.(34,35)”
Scully, T. (2012) · Nature · doi:10.1038/485s2a · Cited by 296
Encapsulation of an Integrated Neural Interface Device With Parylene C
Hsu, J.-M., Rieth, L., Normann, R. A., Tathireddy, P., & Solzbacher, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002155 · Cited by 241
The diabetic foot: a global view
Boulton, A. J. M. (2000) · Diabetes/Metabolism Research and Reviews · doi:10.1002/1520-7560(200009/10)16:1+<::aid-dmrr105>3.0.co;2-n · Cited by 191
Chantelau, E. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01677.x · Cited by 185
Faglia, E., Clerici, G., Caminiti, M. S., Quarantiello, A., Gino, M., & Morabito, A. (2006) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2006.04.002 · Cited by 129
A temperature sensor based on a MWCNT/SEBS nanocomposite
Matzeu, G., Pucci, A., Savi, S., Romanelli, M., & Francesco, F. D. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2012.02.043 · Cited by 120
Self-citationSiersma, V., Thorsen, H., Holstein, P. E., Kars, M., Apelqvist, J., Jude, E. B., Piaggesi, A., Bakker, K., Edmonds, M., Jirkovska, A., et al. (2013) · Diabetic Medicine · doi:10.1111/dme.12254 · Cited by 108
Self-citationHoughton, V. J., Bower, V. M., & Chant, D. C. (2013) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-6-31 · Cited by 107
Diabetic Foot Ulcers and Infections: Current Concepts
Calhoun, J. H., Overgaard, K. A., Stevens, C. M., Dowling, J. P. F., & Mader, J. T. (2002) · Advances in Skin & Wound Care · doi:10.1097/00129334-200201000-00011 · Cited by 97
Dini, V., Salvo, P., Janowska, A., Francesco, F. D., Barbini, A., & Romanelli, M. (2015) · PubMed · Cited by 86
Self-citationThe Diabetic Foot: Consequences of Delayed Treatment and Referral
Mills, J. L., Beckett, W. C., & Taylor, S. M. (1991) · Southern Medical Journal · doi:10.1097/00007611-199108000-00009 · Cited by 85
An overview of temperature monitoring devices for early detection of diabetic foot disorders
Roback, K. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.35 · Cited by 83
The role of biomedical sensors in wound healing
Salvo, P., Dini, V., Francesco, F. D., & Romanelli, M. (2015) · Wound Medicine · doi:10.1016/j.wndm.2015.03.007 · Cited by 74
Self-citationEfficacy and safety of neutral pH superoxidised solution in severe diabetic foot infections
Jesús, F. R. M.-D., la Medina, A. R., Remes-Troche, J. M., Armstrong, D. G., Wu, S., Lázaro‐Martínez, J. L., & Montesinos, J. V. B. (2007) · International Wound Journal · doi:10.1111/j.1742-481x.2007.00363.x · Cited by 59
A Review of the Eurodiale Studies: What Lessons for Diabetic Foot Care?
Akhtar, S., Schaper, N. C., Apelqvist, J., & Jude, E. B. (2011) · Current Diabetes Reports · doi:10.1007/s11892-011-0195-x · Cited by 52
A new polystyrene-based ionomer/MWCNT nanocomposite for wearable skin temperature sensors
Giuliani, A., Placidi, M., Francesco, F. D., & Pucci, A. (2014) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2014.01.008 · Cited by 51
Self-citationFactors affecting the dispersion of MWCNTs in electrically conducting SEBS nanocomposites
Calisi, N., Giuliani, A., Alderighi, M., Schnorr, J. M., Swager, T. M., Francesco, F. D., & Pucci, A. (2013) · European Polymer Journal · doi:10.1016/j.eurpolymj.2013.03.029 · Cited by 42
Self-citationA graphene oxide pH sensor for wound monitoring
Melai, B., Salvo, P., Calisi, N., Moni, L., Bonini, A., Paoletti, C., Lomonaco, T., Mollica, V., Fuoco, R., & Francesco, F. D. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591092 · Cited by 36
Self-citationDiabetic foot ulcer wound fluid: the effects of pH on DFU bacteria and infection
McArdle, C., Lagan, K. M., Spence, S., & McDowell, D. A. (2015) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-8-s1-a8 · Cited by 25
Texier, I., Marcoux, P. R., Pham, P., Muller, M., Benhamou, P., Correvon, M., Dudnik, G., Voirin, G., Bue, N., Cristensen, J., et al. (2013) · International Conference on Embedded Computer Systems: Architectures, Modeling, and Simulation · doi:10.1109/samos.2013.6621116 · Cited by 11
Self-citationDiabetic Foot Ulcers and Infections: Current Concepts
&NA; (2002) · Advances in Skin & Wound Care · doi:10.1097/00129334-200201000-00012 · Cited by 7
Salvo, P., Smajda, R., Dini, V., Saxby, C., Voirin, G., Romanelli, M., & Francesco, F. D. (2016) · Journal of Tissue Viability · doi:10.1016/j.jtv.2016.01.001 · Cited by 6
Self-citationTexier, I., Xydis, S., Soudris, D., Marcoux, P. R., Pham, P., Muller, M., Correvon, M., Dudnik, G., Voirin, G., Kristenssen, J., et al. (2014) · CINECA IRIS Institutial research information system (University of Pisa) · doi:10.1109/mobihealth.2014.7015985 · Cited by 5
Self-citationNon-invasive sensors for wound monitoring and therapy
Salvo, P., Melai, B., BIANCHI, S., CALISI, N., Dini, V., ROMANELLI, M., Castelvetro, V., Paoletti, C., Politino, C., & Francesco, F. D. (2015) · CINECA IRIS Institutial research information system (University of Pisa) · Cited by 3
Self-citationNon-invasive sensors for wound monitoring and therapy
(2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Cited by 2
Research works printed but not linked: 1
- [24]Nagoba BS Suryawanshi NM Wadher B Selkar S Acidic environment and wound healing: a review Wounds 2015 27 1 5 11
Cited by
Diabetic Wound-Healing Science
Burgess, J. L., Wyant, W. A., Abdo Abujamra, B., Kirsner, R. S., & Jozic, I. (2021) · Medicina · doi:10.3390/medicina57101072 · Cited by 928
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Ghoneim, M. T., Nguyen, A., Dereje, N., Huang, J., Moore, G. C., Murzynowski, P. J., & Dagdeviren, C. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00655 · Cited by 317
Smart Bandages: The Future of Wound Care
Derakhshandeh, H., Kashaf, S. S., Aghabaglou, F., Ghanavati, I. O., & Tamayol, A. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.07.007 · Cited by 315
Saliva sampling: Methods and devices. An overview
Bellagambi, F. G., Lomonaco, T., Salvo, P., Vivaldi, F., Hangouët, M., Ghimenti, S., Biagini, D., Di Francesco, F., Fuoco, R., & Errachid, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115781 · Cited by 303
Self-citation
Metadata
- Authors
- Salvo, P., Calisi, N., Melai, B., Dini, V., Paoletti, C., Lomonaco, T., Pucci, A., Di Francesco, F., Piaggesi, A., & Romanelli, M.
- Affiliations
- University of Pisa (IT)
- Corresponding author
- Romanelli, Marco
- ORCID
- Venue
- International Journal of Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2017-01
- Volume
- Volume 12
- Pages
- 949-954
- ISSN
- 1176-9114 (ISSN-L)
- 1178-2013
- PMC
- PMC5293368
- OpenAlex
- W2583551110
- Cited by
- 76
- References
- 42
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 5 · 2023: 13 · 2022: 5 · 2021: 12 · 2020: 9 · 2019: 11 · 2018: 8 · 2017: 2
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- International Journal of Nanomedicine (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Dove Medical Press (Taylor and Francis Group) (submittedVersion, cc-by-nc)
- Funders
- European Commission (317894)
- FP7 Information and Communication Technologies
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Surgery › Wound Healing and Treatments
- Keywords
- diabetic foot ulcer, venous leg ulcers, wearable sensors, temperature sensors, pH sensor, wound monitoring, multi-walled carbon nanotubes, graphene oxide, electrical resistance, nanocomposites
- MeSH terms
- Equipment Design, Graphite, Humans, Hydrogen-Ion Concentration, Polyethylenes, Polystyrenes, Pressure, Sensitivity and Specificity, Temperature, Foot Ulcer, Diabetic Foot, Monitoring, Ambulatory, Nanotubes, Carbon, Nanomedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.