Visualization of cardiac dipole using a current density map: detection of cardiac current undetectable by electrocardiography using magnetocardiography
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A close relationship exists between electric current and the magnetic field. However, electricity and magnetism have different physical characteristics, and magnetocardiography (MCG) may provide information on cardiac current that is difficult to obtain by electrocardiography (ECG). In the present study, we investigated the issue of whether the current density map method, in which cardiac current is estimated from the magnetic gradient, facilitates the visualization of cardiac current undetectable by ECG. The subjects were 50 healthy adults (N group), 40 patients with left ventricular overloading (LVO group), 15 patients with right ventricular overloading (RVO group), 10 patients with an old inferior myocardial infarction (OMI group), and 30 patients with diabetes mellitus (DM group). MCGs were recorded with a second derivative superconducting quantum interference device (SQUID) gradiometer using liquid helium. Isopotential maps and current density maps from unipolar precordial ECG leads and MCGs, respectively, were prepared, and the cardiac electric current was examined. The current density map at the ventricular depolarization phase showed one peak of current density in the N group. However, in the OMI group, the current density map showed multiple peaks of current density areas. In the RVO group, two peaks of current densities were detected at the right superior region and left thoracic region and these two diploles appeared to be from the right and left ventricular derived cardiac currents, respectively. Moreover, there was a significant correlation between the magnitude of the current density from the right ventricle and the systolic pulmonary arterial pressure. The current density map at the ventricular repolarization phase in the N group showed only a single current source. However, abnormal current sources in the current density maps were frequently detected even in patients showing no abnormalities on isopotential maps in the LVO, DM, and OMI groups. The findings herein suggest that opposing dipoles of the ventricular depolarization and repolarization vectors were summed and evaluated as a single dipole in the electrocardiogram. However, MCG facilitated the detection of multiple dipoles because of its superior spatial resolution as well as difference in physical properties between magnetic and electrical fields. Our results suggest that MCG with a current density map is useful for detecting cardiac current undetectable by ECG in an early stage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Zimmerman, J. E., & Frederick, N. V. (1971) · Applied Physics Letters · doi:10.1063/1.1653725 · Cited by 152 · cited 5×
“(1) Ventricular depolarization vectors in patients”
MethodInfluentialKandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345263 · Cited by 45 · cited 1×
“The magnitude of current density (CD) at each position was calculated as follows (4-6).”
Method
Cited by
Bang, W.-D., Kim, K., Lee, Y.-H., Kwon, H., Park, Y., Pak, H.-N., Ko, Y.-G., Lee, M., & Joung, B. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1339 · Cited by 17
“It is, therefore, useful for detecting cardiac changes at early stages that are currently undetectable by ECG.20 Previous studies found that abnormal heterogenous repolarization patterns in T-peak have significant correlation with diagnosis of myocardial ischemia.”
BackgroundResultInfluentialLombardi, G., Sorbo, A. R., Guida, G., La Brocca, L., Fenici, R., & Brisinda, D. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.02.004 · Cited by 10
Huang, X., Hua, N., Tang, F., & Zhang, S. (2020) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-20-121 · Cited by 10
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Metadata
- Authors
- Ikefuji, H., Nomura, M., Nakaya, Y., Mori, T., Kondo, N., Ieishi, K., Fujimoto, S., & Ito, S.
- Venue
- The Journal of Medical Investigation
- Published
- 2007
- Volume
- 54
- Issue
- 1-2
- Pages
- 116-123
- ISSN
- 1343-1420 (ISSN-L)
- 1349-6867
- OpenAlex
- W2159142355
- Cited by
- 19
- References
- 4
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visualization of cardiac dipole using a current density map: detection of cardiac current undetectable by electrocardiography using magnetocardiography. https://app.cochat.ai/papers/10.2152/jmi.54.116
- The paper
- Ikefuji, H., Nomura, M., Nakaya, Y., Mori, T., Kondo, N., Ieishi, K., Fujimoto, S., & Ito, S. (2007). Visualization of cardiac dipole using a current density map: detection of cardiac current undetectable by electrocardiography using magnetocardiography. The Journal of Medical Investigation. https://doi.org/10.2152/jmi.54.116
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.