CoChat

Recommendations for Improved Data Processing from Expired Gas Analysis Indirect Calorimetry

Robergs, Robert A., Dwyer, Dan, Astorino, Todd · 2010 · Sports Medicine

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

There is currently no universally recommended and accepted method of data processing within the science of indirect calorimetry for either mixing chamber or breath-by-breath systems of expired gas analysis. Exercise physiologists were first surveyed to determine methods used to process oxygen consumption ((.)VO2) data, and current attitudes to data processing within the science of indirect calorimetry. Breath-by-breath datasets obtained from indirect calorimetry during incremental exercise were then used to demonstrate the consequences of commonly used time, breath and digital filter post-acquisition data processing strategies. Assessment of the variability in breath-by-breath data was determined using multiple regression based on the independent variables ventilation (VE), and the expired gas fractions for oxygen and carbon dioxide, FEO2 and FECO2, respectively. Based on the results of explanation of variance of the breath-by-breath (.)VO2 data, methods of processing to remove variability were proposed for time-averaged, breath-averaged and digital filter applications. Among exercise physiologists, the strategy used to remove the variability in (.)VO2 measurements varied widely, and consisted of time averages (30 sec [38%], 60 sec [18%], 20 sec [11%], 15 sec [8%]), a moving average of five to 11 breaths (10%), and the middle five of seven breaths (7%). Most respondents indicated that they used multiple criteria to establish maximum ((.)VO2 ((.)VO2max) including: the attainme…

Overview

Integrity signals

Registry

Crossref · 10.2165/11319670-000000000-00000

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 40 references

Research works printed but not linked: 7

  1. Noakes, 1998, Med Sci Sports Exerc, 30, 1381
  2. Robergs, 2001, JEPonline, 4, 1
  3. Cumming, 1972, Med Sci Sports Exerc, 4, 18
  4. Dwyer, 2004, JEPonline, 7, 1
  5. Myers, 1989, Med Sci Sports Exerc, 96, 1312
  6. Astorino, 2000, JEPonline, 3, 1
  7. Weir, 2004, JEPonline, 7, 55

Cited by

See all 358

Metadata

Authors
Robergs, R. A., Dwyer, D., & Astorino, T.
Affiliations
  • University of New Mexico (US)
  • University of Newcastle Australia (AU)
  • California State University System (US)
Corresponding author
Robergs, Robert A.
Venue
Sports Medicine
Published
2010-02
Volume
40
Issue
2
Pages
95-111
ISSN
0112-1642 (ISSN-L)
OpenAlex
W2011094458
Cited by
356
References
40
Citations by year
2026: 24 · 2025: 28 · 2024: 21 · 2023: 28 · 2022: 35 · 2021: 27 · 2020: 26 · 2019: 34 · 2018: 22 · 2017: 26 · 2016: 13 · 2015: 28 · 2014: 14 · 2013: 13 · 2012: 6
FWCI
25.67
Type
journal article
Language
en
Open access
closed
Locations
  • Sports Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • NOVA (University of Newcastle Australia) (submittedVersion)
  • Faculty of Health; Institute of Health and Biomedical Innovation
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
indirect calorimetry, expired gas analysis, oxygen consumption, time averaging, digital filtering, incremental exercise, steady-state exercise, ventilation, respiratory exchange ratio, data variability, rating of perceived exertion
MeSH terms
Electronic Data Processing, Calorimetry, Indirect, Humans, Oxygen Consumption, Exercise, Exhalation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recommendations for Improved Data Processing from Expired Gas Analysis Indirect Calorimetry. https://app.cochat.ai/papers/10.2165/11319670-000000000-00000
The paper
Robergs, R. A., Dwyer, D., & Astorino, T. (2010). Recommendations for Improved Data Processing from Expired Gas Analysis Indirect Calorimetry. Sports Medicine. https://doi.org/10.2165/11319670-000000000-00000

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.