The DOI matches its Crossref record.
Mathematical phantoms representing children of various ages for use in estimates of internal dose
Open accessAbstract
In the mid-1960's, Fisher and Snyder developed a mathematical phantom of an adult human for use in internal dose estimations in conjunction with a Monte Carlo transport code for photons. Simple equations defining the boundaries of the body and the principal organs were given for this phantom. To estimate dose in children, Snyder and co-workers employed phantoms that were transformations of the adult phantom. Equations for major body sections were given explicitly, with the internal organs defined implicitly through similitude transformation equations. The major shortcoming of these derivative phantoms was that the organ sizes and bone marrow distributions were not always realistic. To overcome this shortcoming, a series of distinct phantoms representing children of ages 0, 1, 5, 10, and 15 years has been developed. All equations for boundaries of organs are explicitly defined with realistic sizes. In addition, the regional distributions of hematopoietically active bone marrow and inactive fatty marrow have been assigned for each phantom, using the method of Cristy. Because detailed anatomical data for organ shapes and locations are not available for children, the ''Similitude Rule'' was used to determine the shape and the location of most of the organs. This rule is consistent with drawings depicting developmental trends of organs in the trunk. Known exceptions to the rule were adjusted appropriately. The organ volumes were assigned such that organ masses at the various ages conform closely with the data presented in International Commission on Radiological Protection Publication 23. 41 refs., 33 figs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deak, P. D., Smal, Y., & Kalender, W. A. (2010) · Radiology · doi:10.1148/radiol.10100047 · Cited by 858
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Christner, J. A., Kofler, J. M., & McCollough, C. H. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3462 · Cited by 492
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Ector, J., Dragusin, O., Adriaenssens, B., Huybrechts, W., Willems, R., Ector, H., & Heidbüchel, H. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.040 · Cited by 201
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
Dose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT)
Thierry-Chef, I., Ferro, G., Le Cornet, L., Dabin, J., Istad, T. S., Jahnen, A., Lee, C., Maccia, C., Malchair, F., Olerud, H. M., et al. (2021) · Radiation Research · doi:10.1667/rade-20-00231.1 · Cited by 31
Metadata
- Authors
- Cristy, M.
- Published
- 1980-06-01
- OpenAlex
- W4397020252
- Cited by
- 167
- References
- 0
- Type
- report
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.