Cited by 271Sepsis Diagnosis and TreatmentImmune Response and InflammationInflammation biomarkers and pathways

Human endotoxemia as a model of systemic inflammation

Andreasen, A., Krabbe, K., Krogh-Madsen, R., Taudorf, S., Pedersen, B., Moller, K.·2008·Current Medicinal Chemistry

Abstract

Systemic inflammation is a pathogenetic component in a vast number of acute and chronic diseases such as sepsis, trauma, type 2 diabetes, atherosclerosis, and Alzheimer's disease, all of which are associated with a substantial morbidity and mortality. However, the molecular mechanisms and physiological significance of the systemic inflammatory response are still not fully understood. The human endotoxin model, an in vivo model of systemic inflammation in which lipopolysaccharide is injected or infused intravenously in healthy volunteers, may be helpful in unravelling these issues. The present review addresses the basic changes that occur in this model. The activation of inflammatory cascades as well as organ-specific haemodynamic and functional changes after lipopolysaccharide are described, and the limitations of human-experimental models for the study of clinical disease are discussed. Finally, we outline the ethical considerations that apply to the use of human endotoxin model.

Integrity signals

Registry

Crossref · 10.2174/092986708784872393

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Endotoxin produces a robust but short-term inflammatory response ranging from 40 to 190 pg/mL (up to a 38000% increase) two hours after injection, depending on bacterial strain and dose.

    “Endotoxin results in a robust but short-term inflammatory response that ranges from 40 to 190 pg/mL (up to a 38000% increase) two hours after injection depending on the bacterial strain and dose (Andreasen et al., 2008; Grigoleit et al., 2011).”

Cited by

Sorted by citations

Authors
Andreasen, A., Krabbe, K., Krogh-Madsen, R., Taudorf, S., Pedersen, B., & Moller, K.
Affiliations
  • University of Copenhagen (DK)
  • Rigshospitalet (DK)
Venue
Current Medicinal Chemistry
Published
2008-07-01
Volume
15
Issue
17
Pages
1697-1705
ISSN
0929-8673 (ISSN-L)
OpenAlex
W2118124014
Cited by
271
References
0
Citations by year
2026: 5 · 2025: 12 · 2024: 6 · 2023: 16 · 2022: 13 · 2021: 21 · 2020: 11 · 2019: 11 · 2018: 20 · 2017: 15 · 2016: 20 · 2015: 29 · 2014: 19 · 2013: 20 · 2012: 22
FWCI
7.67
Type
journal article
Language
en
Open access
closed
Locations
  • Current Medicinal Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Danmarks Grundforskningsfond
Topics
  • Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
  • Life Sciences › Immunology and Microbiology › Immunology › Immune Response and Inflammation
  • Life Sciences › Immunology and Microbiology › Immunology › Inflammation biomarkers and pathways
Keywords
endotoxemia, systemic inflammation, lipopolysaccharide, sepsis, inflammatory cascade, research ethics, type 2 diabetes, atherosclerosis, Alzheimer's disease
MeSH terms
Humans, Leukocytes, Models, Biological, Cytokines, Systemic Inflammatory Response Syndrome, Endotoxemia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review