The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Phase-Change Contrast Agents for Imaging and Therapy
Open accessAbstract
Phase-change contrast agents (PCCAs) for ultrasound-based applications have resulted in novel ways of approaching diagnostic and therapeutic techniques beyond what is possible with microbubble contrast agents and liquid emulsions. When subjected to sufficient pressures delivered by an ultrasound transducer, stabilized droplets undergo a phase-transition to the gaseous state and a volumetric expansion occurs. This phenomenon, termed acoustic droplet vaporization, has been proposed as a means to address a number of in vivo applications at the microscale and nanoscale. In this review, the history of PCCAs, physical mechanisms involved, and proposed applications are discussed with a summary of studies demonstrated in vivo. Factors that influence the design of PCCAs are discussed, as well as the need for future studies to characterize potential bioeffects for administration in humans and optimization of ultrasound parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regulation of transport pathways in tumor vessels: Role of tumor type and microenvironment
Hobbs, S. K., Monsky, W. L., Yuan, F., Roberts, W. G., Griffith, L., Torchilin, V. P., & Jain, R. K. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4607 · Cited by 2,438
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Ultrasound Microbubble Contrast Agents: Fundamentals and Application to Gene and Drug Delivery
Ferrara, K., Pollard, R., & Borden, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095852 · Cited by 1,288
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Survival of Mammals Breathing Organic Liquids Equilibrated with Oxygen at Atmospheric Pressure
Clark, L. C., & Gollan, F. (1966) · Science · doi:10.1126/science.152.3730.1755 · Cited by 794
Acoustic droplet vaporization for therapeutic and diagnostic applications
Kripfgans, O. D., Fowlkes, J. B., Miller, D. L., Eldevik, O. P., & Carson, P. L. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00262-3 · Cited by 572
Multifunctional Nanoparticles for Combining Ultrasonic Tumor Imaging and Targeted Chemotherapy
Rapoport, N., Gao, Z., & Kennedy, A. (2007) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djm043 · Cited by 562
Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
Rapoport, N. Y., Kennedy, A. M., Shea, J. E., Scaife, C. L., & Nam, K.-H. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.026 · Cited by 551
Fluorocarbons and fluorinated amphiphiles in drug delivery and biomedical research
Krafft, M. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00107-7 · Cited by 550
A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective
Miller, M. W., Miller, D. L., & Brayman, A. A. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00089-0 · Cited by 528
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Microbubble-enhanced US in Body Imaging: What Role?
Wilson, S. R., & Burns, P. N. (2010) · Radiology · doi:10.1148/radiol.10091210 · Cited by 470
Micelles and nanoparticles for ultrasonic drug and gene delivery
Husseini, G. A., & Pitt, W. G. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.008 · Cited by 468
Klibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Rapoport, N., Nam, K.-H., Gupta, R., Gao, Z., Mohan, P., Payne, A., Todd, N., Liu, X., Kim, T., Shea, J., et al. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.01.022 · Cited by 423
Price, R. J., Skyba, D. M., Kaul, S., & Skalak, T. C. (1998) · Circulation · doi:10.1161/01.cir.98.13.1264 · Cited by 393
Winter, P. M., Caruthers, S. D., Kassner, A., Harris, T. D., Chinen, L. K., Allen, J. S., Lacy, E. K., Zhang, H., Robertson, J. D., Wickline, S. A., et al. (2003) · PubMed · Cited by 371
Holt, R. G., & Roy, R. A. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00438-0 · Cited by 359
Microbubble-enhanced ultrasound for vascular gene delivery
Lawrie, A., Brisken, A., Francis, S., Cumberland, D., Crossman, D., & Newman, C. (2000) · Gene Therapy · doi:10.1038/sj.gt.3301339 · Cited by 343
Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis
Tachibana, K., & Tachibana, S. (1995) · Circulation · doi:10.1161/01.cir.92.5.1148 · Cited by 343
Phagocytosis of ultrasound contrast agent microbubbles by Kupffer cells
Yanagisawa, K., Moriyasu, F., Miyahara, T., Yuki, M., & Iijima, H. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.08.008 · Cited by 343
Mohan, P., & Rapoport, N. (2010) · Molecular Pharmaceutics · doi:10.1021/mp100269f · Cited by 331
Acoustic radiation force in vivo: a mechanism to assist targeting of microbubbles
Dayton, P., Klibanov, A., Brandenburger, G., & Ferrara, K. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00062-9 · Cited by 330
Drug-loaded nano/microbubbles for combining ultrasonography and targeted chemotherapy
Gao, Z., Kennedy, A. M., Christensen, D. A., & Rapoport, N. Y. (2008) · Ultrasonics · doi:10.1016/j.ultras.2007.11.002 · Cited by 316
Gravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
Sheeran, P. S., Luois, S., Dayton, P. A., & Matsunaga, T. O. (2011) · Langmuir · doi:10.1021/la2013705 · Cited by 309
Partlow, K. C., Chen, J., Brant, J. A., Neubauer, A. M., Meyerrose, T. E., Creer, M. H., Nolta, J. A., Caruthers, S. D., Lanza, G. M., & Wicldine, S. A. (2007) · The FASEB Journal · doi:10.1096/fj.06-6505com · Cited by 306
Subharmonic imaging of contrast agents
Forsberg, F., Shi, W. T., & Goldberg, B. B. (2000) · Ultrasonics · doi:10.1016/s0041-624x(99)00148-1 · Cited by 303
Ultrasound radiation force enables targeted deposition of model drug carriers loaded on microbubbles
Lum, A. F. H., Borden, M. A., Dayton, P. A., Kruse, D. E., Simon, S. I., & Ferrara, K. W. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.11.006 · Cited by 262
Decafluorobutane as a Phase-Change Contrast Agent for Low-Energy Extravascular Ultrasonic Imaging
Sheeran, P. S., Wong, V. P., Luois, S., McFarland, R. J., Ross, W. D., Feingold, S., Matsunaga, T. O., & Dayton, P. A. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.021 · Cited by 244
The role of inertial cavitation in acoustic droplet vaporization
Fabiilli, M. L., Haworth, K. J., Fakhri, N. H., Kripfgans, O. D., Carson, P. L., & Fowlkes, J. B. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1132 · Cited by 232
On the acoustic vaporization of micrometer-sized droplets
Kripfgans, O. D., Fabiilli, M. L., Carson, P. L., & Fowlkes, J. B. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1755236 · Cited by 221
Intravascular ultrasound molecular imaging of atheroma components in vivo
Hamilton, A. J., Huang, S.-L., Warnick, D., Rabbat, M., Kane, B., Nagaraj, A., Klegerman, M., & McPherson, D. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.07.048 · Cited by 215
Ultrasound-mediated cavitation thresholds of liquid perfluorocarbon droplets in vitro
Giesecke, T., & Hynynen, K. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00980-3 · Cited by 207
Microbubble-enhanced cavitation for noninvasive ultrasound surgery
Tran, B. C., Seo, J., Hall, T. L., Fowlkes, J. B., & Cain, C. A. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1244746 · Cited by 182
Contrast-Enhanced Ultrasound Imaging of the Vasa Vasorum
Staub, D., Schinkel, A. F. L., Coll, B., Coli, S., van der Steen, A. F. W., Reed, J. D., Krueger, C., Thomenius, K. E., Adam, D., Sijbrands, E. J., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.02.007 · Cited by 179
Pisani, E., Tsapis, N., Paris, J., Nicolas, V., Cattel, L., & Fattal, E. (2006) · Langmuir · doi:10.1021/la0601455 · Cited by 175
Liquid Perfluorocarbons as Contrast Agents for Ultrasonography and 19F-MRI
Díaz-López, R., Tsapis, N., & Fattal, E. (2009) · Pharmaceutical Research · doi:10.1007/s11095-009-0001-5 · Cited by 167
Zhang, P., & Porter, T. M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.07.001 · Cited by 166
Investigation of Vaporized Submicron Perfluorocarbon Droplets as an Ultrasound Contrast Agent
Reznik, N., Williams, R., & Burns, P. N. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.001 · Cited by 160
Delivery of Water-Soluble Drugs Using Acoustically Triggered Perfluorocarbon Double Emulsions
Fabiilli, M. L., Lee, J. A., Kripfgans, O. D., Carson, P. L., & Fowlkes, J. B. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0277-5 · Cited by 157
Srinivas, M., Cruz, L. J., Bonetto, F. J., Heerschap, A., Figdor, C. G., & de Vries, I. J. M. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.069 · Cited by 157
Vaporization of perfluorocarbon droplets using optical irradiation
Strohm, E. M., Rui, M., Gorelikov, I., Matsuura, N., & Kolios, M. C. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.001432 · Cited by 152
Targeted ultrasonic contrast agents for molecular imaging and therapy
Lanza, G. M., & Wickline, S. A. (2001) · Progress in Cardiovascular Diseases · doi:10.1053/pcad.2001.26440 · Cited by 151
Rychak, J. J., Klibanov, A. L., & Hossack, J. A. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1417264 · Cited by 149
In vivo droplet vaporization for occlusion therapy and phase aberration correction
Kripfgans, O. D., Fowlkes, J. B., Woydt, M., Eldevik, O. P., & Carson, P. L. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1009331 · Cited by 140
Fluorocarbon-Based in vivo Oxygen Transport and Delivery Systems
Riess, J. G. (1991) · Vox Sanguinis · doi:10.1159/000461363 · Cited by 139
Optical and Acoustical Dynamics of Microbubble Contrast Agents inside Neutrophils
Dayton, P. A., Chomas, J. E., Lum, A. F. H., Allen, J. S., Lindner, J. R., Simon, S. I., & Ferrara, K. W. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76127-9 · Cited by 136
Molecular imaging with contrast ultrasound and targeted microbubbles
Lindner, J. R. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2004.01.003 · Cited by 133
Perfluorooctylbromide: a new contrast agent for CT, sonography, and MR imaging
Mattrey, R. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.2.247 · Cited by 126
Tumor Physiology and Delivery of Nanopharmaceuticals
Campbell, R. B. (2006) · Anti-Cancer Agents in Medicinal Chemistry · doi:10.2174/187152006778699077 · Cited by 124
Application of Ultrasound to Selectively Localize Nanodroplets for Targeted Imaging and Therapy
Dayton, P. A., Zhao, S., Bloch, S. H., Schumann, P., Penrose, K., Matsunaga, T. O., Zutshi, R., Doinikov, A. A., & Ferrara, K. W. (2006) · Molecular Imaging · doi:10.2310/7290.2006.00019 · Cited by 123
Acoustic droplet vaporization threshold: effects of pulse duration and contrast agent
Lo, A. H., Kripfgans, O. D., Carson, P. L., Rothman, E. D., & Fowlkes, J. B. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.339 · Cited by 121
Mullin, L. B., Gessner, R. C., Kwan, J., Kaya, M., Borden, M. A., & Dayton, P. A. (2011) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.414 · Cited by 113
In vitrocharacterization of perfluorocarbon droplets for focused ultrasound therapy
Schad, K. C., & Hynynen, K. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/17/004 · Cited by 112
Microbubble generation in phase-shift nanoemulsions used as anticancer drug carriers
Rapoport, N. Y., Efros, A., Christensen, D. A., Kennedy, A., & Nam, K.-H. (2009) · Bubble Science Engineering & Technology · doi:10.1179/175889709x446516 · Cited by 109
Tumor interstitial fluid pressure as an early-response marker for anticancer therapeutics
Ferretti, S., Allegrini, P. R., Becquet, M. M., & McSheehy, P. M. J. (2009) · Neoplasia · doi:10.1593/neo.09554 · Cited by 106
Perfluorocarbon blood substitutes
Biro, G. P., Blais, P., & Rosen, A. L. (1987) · Critical Reviews in Oncology/Hematology · doi:10.1016/s1040-8428(87)80018-5 · Cited by 103
Caruthers, S. D., Neubauer, A. M., Hockett, F. D., Lamerichs, R. M. J. N., Winter, P. M., Scott, M. J., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199281.60135.6a · Cited by 101
A new imaging strategy using wideband transient response of ultrasound contrast agents
Kruse, D. E., & Ferrara, K. W. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1509790 · Cited by 101
Theragnostics for tumor and plaque angiogenesis with perfluorocarbon nanoemulsions
Lanza, G., Winter, P. M., Caruthers, S. D., Hughes, M. S., Hu, G., Schmieder, A. H., & Wickline, S. A. (2010) · Angiogenesis · doi:10.1007/s10456-010-9166-0 · Cited by 96
Enhanced detection of thrombi with a novel fibrin-targeted magnetic resonance imaging agent
Lanza, G. M., Lorenz, C. H., Fischer, S., Scott, M. J., Cacheris, W. P., Kaufmann, R. J., Gaffney, P. J., & Wickline, S. A. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80097-4 · Cited by 90
Ultrasonic Nanotherapy of Pancreatic Cancer: Lessons from Ultrasound Imaging
Rapoport, N. Y., Kennedy, A., Shea, J., Scaife, C. L., & Nam, K.-H. (2009) · Molecular Pharmaceutics · doi:10.1021/mp900128x · Cited by 90
Targeting of ultrasound contrast material. An in vitro feasibility study.
Klibanov, A. L., Hughes, M. S., Marsh, J. N., Hall, C. S., Miller, J. G., Wible, J. H., & Brandenburger, G. H. (1997) · PubMed · Cited by 80
Perfluorooctylbromide as a contrast agent for CT and sonography: preliminary clinical results.
Behan, M., O'Connell, D. J., Mattrey, R. F., & Carney, D. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.160.2.8424361 · Cited by 79
Cavitation properties of block copolymer stabilized phase-shift nanoemulsions used as drug carriers
Rapoport, N., Christensen, D. A., Kennedy, A. M., & Nam, K.-H. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.11.009 · Cited by 79
Ultrasound-Assisted Thrombolysis for Stroke Therapy
Hitchcock, K. E., & Holland, C. K. (2010) · Stroke · doi:10.1161/strokeaha.110.595348 · Cited by 76
1H/19F Magnetic Resonance Molecular Imaging with Perfluorocarbon Nanoparticles
Lanza, G. M., Winter, P. M., Neubauer, A. M., Caruthers, S. D., Hockett, F. D., & Wickline, S. A. (2005) · Current topics in developmental biology/Current Topics in Developmental Biology · doi:10.1016/s0070-2153(05)70003-x · Cited by 75
Microbubble Expansion in a Flexible Tube
Tao, Y., & Bull, J. L. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2206200 · Cited by 70
Heat-sensitive microbubbles for intraoperative assessment of cancer ablation margins
Huang, J., Xu, J. S., & Xu, R. X. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.008 · Cited by 68
Marsh, J. N., Hall, C. S., Scott, M. J., Fuhrhop, R. W., Gaffney, P. J., Wickline, S. A., & Lanza, G. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.981381 · Cited by 67
Direct Numerical Simulations of Micro-Bubble Expansion in Gas Embolotherapy
Ye, T., & Bull, J. L. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1824131 · Cited by 66
Kang, S., & Yeh, C. (2011) · Langmuir · doi:10.1021/la203212p · Cited by 63
Miller, D. L., & Thomas, R. M. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00126-3 · Cited by 58
Bubble splitting in bifurcating tubes: a model study of cardiovascular gas emboli transport
Calderón, A. J., Fowlkes, J. B., & Bull, J. L. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00656.2004 · Cited by 54
Application of ultrasound for targeted nanotherapy of malignant tumors
Rapoport, N. Y., Nam, K. H., Gao, Z., & Kennedy, A. (2009) · Acoustical Physics · doi:10.1134/s1063771009040162 · Cited by 53
Clasohm, L. Y., Vakarelski, I. U., Dagastine, R. R., Chan, D. Y. C., Stevens, G. W., & Grieser, F. (2007) · Langmuir · doi:10.1021/la701568r · Cited by 52
Internalization of microbubbles by tumor cellsin vivo andin vitro
Barbarese, E., Ho, S., D'Arrigo, J. S., & Simon, R. H. (1995) · Journal of Neuro-Oncology · doi:10.1007/bf01054766 · Cited by 45
Koch, C. J., Oprysko, P. R., Shuman, A. L., Jenkins, W. T., Brandt, G., & Evans, S. M. (2002) · PubMed · Cited by 32
Perfluorohexane-loaded Macrophages as a Novel Ultrasound Contrast Agent: A Feasibility Study
Kornmann, L. M., Curfs, D. M. J., Hermeling, E., van der Made, I., de Winther, M. P. J., Reneman, R. S., Reesink, K. D., & Hoeks, A. P. G. (2008) · Molecular Imaging and Biology · doi:10.1007/s11307-008-0146-3 · Cited by 17
Hall, C. S., Lanza, G., Rose, J. H., Kaufman, R. J., Fuhrhop, R. W., Handley, S. H., Waters, K. R., Miller, J. G., & Wickline, S. A. (2002) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1997.663303 · Cited by 10
Cited by
State-of-the-art materials for ultrasound-triggered drug delivery
Sirsi, S. R., & Borden, M. A. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.010 · Cited by 488
External triggering and triggered targeting strategies for drug delivery
Wang, Y., & Kohane, D. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.20 · Cited by 418
Structural and functional photoacoustic molecular tomography aided by emerging contrast agents
Nie, L., & Chen, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00086b · Cited by 383
Ultrasound-Responsive Cavitation Nuclei for Therapy and Drug Delivery
Kooiman, K., Roovers, S., Langeveld, S. A. G., Kleven, R. T., Dewitte, H., O'Reilly, M. A., Escoffre, J.-M., Bouakaz, A., Verweij, M. D., Hynynen, K., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.01.002 · Cited by 359
A targeted approach to cancer imaging and therapy
Li, C. (2014) · Nature Materials · doi:10.1038/nmat3877 · Cited by 268
Metadata
- Authors
- S. Sheeran, P., & A.Dayton, P.
- Venue
- Current Pharmaceutical Design
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2012-03-01
- Volume
- 18
- Issue
- 15
- Pages
- 2152-2165
- ISSN
- 1381-6128 (ISSN-L)
- OpenAlex
- W2335546580
- Cited by
- 253
- References
- 81
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.