Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Open accessPublished version of a preprint
The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Although designed as a consumer product to help motivate individuals to be physically active, Fitbit activity trackers are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform health care decisions. OBJECTIVE: The objective of this review was to systematically evaluate and report measurement accuracy for Fitbit activity trackers in controlled and free-living settings. METHODS: We conducted electronic searches using PubMed, EMBASE, CINAHL, and SPORTDiscus databases with a supplementary Google Scholar search. We considered original research published in English comparing Fitbit versus a reference- or research-standard criterion in healthy adults and those living with any health condition or disability. We assessed risk of bias using a modification of the Consensus-Based Standards for the Selection of Health Status Measurement Instruments. We explored measurement accuracy for steps, energy expenditure, sleep, time in activity, and distance using group percentage differences as the common rubric for error comparisons. We conducted descriptive analyses for frequency of accuracy comparisons within a ±3% error in controlled and ±10% error in free-living settings and assessed for potential bias of over- or underestimation. We secondarily explored how variations in body placement, ambulation speed, or type of activity influenced accuracy. RESULTS: We included 67 studies. Consistent evidence indicated that Fitbit devices were likely to meet acceptable accuracy for step count approximately half the time, with a tendency to underestimate steps in controlled testing and overestimate steps in free-living settings. Findings also suggested a greater tendency to provide accurate measures for steps during normal or self-paced walking with torso placement, during jogging with wrist placement, and during slow or very slow walking with ankle placement in adults with no mobility limitations. Consistent evidence indicated that Fitbit devices were unlikely to provide accurate measures for energy expenditure in any testing condition. Evidence from a few studies also suggested that, compared with research-grade accelerometers, Fitbit devices may provide similar measures for time in bed and time sleeping, while likely markedly overestimating time spent in higher-intensity activities and underestimating distance during faster-paced ambulation. However, further accuracy studies are warranted. Our point estimations for mean or median percentage error gave equal weighting to all accuracy comparisons, possibly misrepresenting the true point estimate for measurement bias for some of the testing conditions we examined. CONCLUSIONS: Other than for measures of steps in adults with no limitations in mobility, discretion should be used when considering the use of Fitbit devices as an outcome measurement tool in research or to inform health care decisions, as there are seemingly a limited number of situations where the device is likely to provide accurate measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The Fitbit Charge HR was chosen as a lower-cost alternative to actigraphy with comparable performance on sleep/wake classification measures (43).”
From Nightly sleep duration predicts grade point average in the first year of college (2023) · cites this paper as [43]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The Fitbit Flex 2 was chosen as it provided an objective measure of sleep with acceptable accuracy at a reasonable cost (43).”
From Nightly sleep duration predicts grade point average in the first year of college (2023) · cites this paper as [43]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“however, a recent review into the use of Fitbit activity trackers suggests that steps are overestimated in free-living conditions [81].”
From Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis (2019) · cites this paper as [81]
In the citing paper
“using a modification of the modified Consensus-Based Standards for the Selection of Health Status Measurement Instruments (COSMIN) validation subscale used by Feehan et al [13] and an a priori modified COSMIN reliability subscale (Multimedia Appendix 2) to assess the quality and risk of bias of each study (EC and DF)”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [13]
In the citing paper
“Our interpretation of measurement accuracy was focused on acceptable limits of percentage difference of ±3% in controlled settings and percentage difference of ±10% in free-living settings, as outlined in previous work [13].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [13]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2010) · International Journal of Surgery · doi:10.1016/j.ijsu.2010.02.007 · Cited by 12,156
Mokkink, L. B., Terwee, C. B., Patrick, D. L., Alonso, J., Stratford, P. W., Knol, D. L., Bouter, L. M., & de Vet, H. C. W. (2010) · Quality of Life Research · doi:10.1007/s11136-010-9606-8 · Cited by 4,260 · cited 1×
“All articles were independently assessed for risk of bias by 2 independent reviewers (JG, CP) using a modification of the validation subscale from the checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments (Consensus-Based Standards for the Sele…”
MethodSteffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
Terwee, C. B., Mokkink, L. B., Knol, D. L., Ostelo, R. W. J. G., Bouter, L. M., & de Vet, H. C. W. (2012) · Quality of Life Research · doi:10.1007/s11136-011-9960-1 · Cited by 1,978 · cited 1×
“We rated each dimension as excellent, good, fair, or poor quality based on a priori modifications to the COSMIN validation subscale scoring criteria appropriate for accuracy studies (Multimedia Appendix 4) [16].”
MethodWhite Paper: “Walking Speed: the Sixth Vital Sign”
Fritz, S., & Lusardi, M. (2009) · Journal of Geriatric Physical Therapy · doi:10.1519/00139143-200932020-00002 · Cited by 1,390 · cited 1×
“When we further explored factors potentially influencing step count accuracy, we observed that accuracy of step count in controlled settings seemed to vary with speed of ambulation (jog, normal, self-paced, slow, or very slow) [50,51], with body placement (torso, wrist, or ankle), and with variations in how the body m…”
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 2×
“[Fitbit devices] and their ability to estimate steps, distance, physical activity, energy expenditure, and sleep” [11].”
BackgroundPedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752 · cited 2×
“We focused our interpretation of measurement accuracy based on predefined acceptable limits for measurement accuracy in controlled settings as a percentage difference of ±3% and acceptable limits for relative accuracy in free-living settings as a percentage difference of ±10% [19-22].”
MethodAccuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633 · cited 2×
“We focused our interpretation of measurement accuracy based on predefined acceptable limits for measurement accuracy in controlled settings as a percentage difference of ±3% and acceptable limits for relative accuracy in free-living settings as a percentage difference of ±10% [19-22].”
MethodHenriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
Research works printed but not linked: 5
- Fitbit Reports $571M Q4’17 and $1.616B FY’17 Revenue201802262018-08-01fitbit.comhttps://investor.fitbit.com/press/press-releases/press-release-details/2018/Fitbit-Reports-571M-Q417-and-1616B-FY17-Revenue/default.aspx
- Rosenberg, D, 2016, AMIA Annu Symp Proc, 2016, 1050
- Popay, J, 2006, Guidance on the Conduct of Narrative Synthesis in Systematic Reviews. A Product From the ESRC Methods Programme. Version 1: April 2006
- Montes, J, 2017, J Exerc Physiol Online, 20, 134
- Stackpool, CM, 2014, J Fit Res, 3, 32
Cited by
Items 601–615 of 615
Salvatore, G. M., Benasi, G., Harsora, R., Butryn, M. L., Mogle, J. A., & Arigo, D. (2026) · Health Psychology and Behavioral Medicine · doi:10.1080/21642850.2026.2706211
“There is potential for underestimation of non-step based activities (Feehan et al., 2018) (e.g. resistance training) and accurate estimates rely on consistent participant device wear and syncing.”
Chae, K., Jones, M. R., Yang, A., Ghosh, J., Rajagopal, S., & Chao, A. M. (2026) · Diabetes Obesity and Cardiometabolic CARE · doi:10.2337/doc26-0062
Siong, C. N., Yi, T. P., Kuan, G., & Cheng, K. Y. (2026) · Lecture notes in bioengineering · doi:10.1007/978-981-95-9653-9_5
Singh, R. B., Fortune, E., Tetrick, M. K., Gogineni, A., Presley, C. J., Reddy, R. G., Hery, C. M. B., Fisher, J. L., Kargarandehkordi, A., Washington, P. Y., et al. (2026) · JMIR Formative Research · doi:10.2196/100764
“…walking in healthy adults, but their accuracy is inconsistent overall, as these devices tend to undercount steps in controlled settings and lose accuracy at slow walking speeds, when worn on the wrist relative to the hip or torso, and in older or mobility-impaired populations [15,16].”
Jenssen, M. D. K., Fors, E. A., Berntsen, G., Fagerlund, A. J., Bellika, J. G., & Godtliebsen, F. (2026) · Applied Sciences · doi:10.3390/app16168209
Hamdani, N., Saragiotto, B. T., Stubbs, P. W., Oliveira, J., Tiedemann, A., Sherrington, C., Santana, P., Ferretti, G. M., Verhagen, A. P., & Mehta, P. (2026) · The Journal of Frailty & Aging · doi:10.1016/j.tjfa.2026.100180
“Activity trackers are wearable, non-invasive devices that monitor physical activity parameters such as steps, energy expenditure, sleep duration, and activity intensity [23,24].”
Ravindranathan, G., Stockton, B., Finnerty, J., Collier, A., & Cassidy, J. W. (2026) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2026.09.012
Kaabi, N. A., Camacho, E., Al-Timimi, A., Andrawes, R. R., Masthan, M. I., Momen, R., Reid, W. D., Slepian, P. M., McGillis, L., Rachinsky, M., et al. (2026) · Respiratory Medicine · doi:10.1016/j.rmed.2026.109158
Castillo, W. C., Damachi, U., ONASANYA, O., Reeves, G. M., & dosReis, S. (2026) · Journal of Affective Disorders · doi:10.1016/j.jad.2026.122519
Im, C.-H., & Woo, M. (2026) · Health Policy and Technology · doi:10.1016/j.hlpt.2026.101322
He, Q., Zhang, J., Beevers, C. G., & Brown, D. M. Y. (2026) · Nature Mental Health · doi:10.1038/s44220-026-00738-x
Rojas-Ledezma, M., Kittelson, A. J., Carson, J., Quindry, J. C., Schubert, M. C., & Loyd, B. J. (2026) · Neurology Report · doi:10.1097/npt.0000000000000584
Vanrusselt, D., Sleurs, C., Leenaerts, N., Kirsch, S., Ermengem, N. V., Lemiere, J., Myin‐Germeys, I., Uyttebroeck, A., & Verschueren, S. (2026) · Digital Health · doi:10.1177/20552076261494729
Home Monitoring Systems: IoT and AI Innovation for Cardio-Cerebrovascular Disease Care
Colpas, P. P. A., Triana, M. A. U., Melo, M. A. P., Parra, E. R., Yepes, J. D. L. R., Bonilla, L. V. T., Giraldo, B. S., López, W. R., & Ocampo, I. C. E. (2025) · IntechOpen eBooks · doi:10.5772/intechopen.1010843
Metadata
- Authors
- Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C.
- Affiliations
- University of British Columbia (CA)
- Corresponding author
- Feehan, Lynne M
- ORCID
- Venue
- JMIR mHealth and uHealth
- Publisher
- JMIR Publications Inc.
- Published
- 2018-08-09
- Volume
- 6
- Issue
- 8
- Pages
- e10527
- ISSN
- 2291-5222 (ISSN-L)
- PMC
- PMC6107736
- OpenAlex
- W2883411829
- Semantic Scholar
- 2a26625e52767429985e16a354821d08a66c5799
- Cited by
- 616
- References
- 86
- Citations by year
- 2026: 69 · 2025: 72 · 2024: 86 · 2023: 62 · 2022: 84 · 2021: 80 · 2020: 130 · 2019: 30 · 2018: 2
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR mhealth and uhealth (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Simon Fraser University
- Canadian Institutes of Health Research (316595)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- Fitbit, wearable activity trackers, wearable devices, measurement accuracy, step count, energy expenditure, sleep monitoring, distance measurement, accelerometer, free-living conditions, physical activity measurement, health promotion research, consumer health technology, measurement bias, adults with disabilities, healthy adults, healthcare decision-making
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.