Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Open accessPublished version of a preprint
The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Although designed as a consumer product to help motivate individuals to be physically active, Fitbit activity trackers are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform health care decisions. OBJECTIVE: The objective of this review was to systematically evaluate and report measurement accuracy for Fitbit activity trackers in controlled and free-living settings. METHODS: We conducted electronic searches using PubMed, EMBASE, CINAHL, and SPORTDiscus databases with a supplementary Google Scholar search. We considered original research published in English comparing Fitbit versus a reference- or research-standard criterion in healthy adults and those living with any health condition or disability. We assessed risk of bias using a modification of the Consensus-Based Standards for the Selection of Health Status Measurement Instruments. We explored measurement accuracy for steps, energy expenditure, sleep, time in activity, and distance using group percentage differences as the common rubric for error comparisons. We conducted descriptive analyses for frequency of accuracy comparisons within a ±3% error in controlled and ±10% error in free-living settings and assessed for potential bias of over- or underestimation. We secondarily explored how variations in body placement, ambulation speed, or type of activity influenced accuracy. RESULTS: We included 67 studies. Consistent evidence indicated that Fitbit devices were likely to meet acceptable accuracy for step count approximately half the time, with a tendency to underestimate steps in controlled testing and overestimate steps in free-living settings. Findings also suggested a greater tendency to provide accurate measures for steps during normal or self-paced walking with torso placement, during jogging with wrist placement, and during slow or very slow walking with ankle placement in adults with no mobility limitations. Consistent evidence indicated that Fitbit devices were unlikely to provide accurate measures for energy expenditure in any testing condition. Evidence from a few studies also suggested that, compared with research-grade accelerometers, Fitbit devices may provide similar measures for time in bed and time sleeping, while likely markedly overestimating time spent in higher-intensity activities and underestimating distance during faster-paced ambulation. However, further accuracy studies are warranted. Our point estimations for mean or median percentage error gave equal weighting to all accuracy comparisons, possibly misrepresenting the true point estimate for measurement bias for some of the testing conditions we examined. CONCLUSIONS: Other than for measures of steps in adults with no limitations in mobility, discretion should be used when considering the use of Fitbit devices as an outcome measurement tool in research or to inform health care decisions, as there are seemingly a limited number of situations where the device is likely to provide accurate measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The Fitbit Charge HR was chosen as a lower-cost alternative to actigraphy with comparable performance on sleep/wake classification measures (43).”
From Nightly sleep duration predicts grade point average in the first year of college (2023) · cites this paper as [43]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The Fitbit Flex 2 was chosen as it provided an objective measure of sleep with acceptable accuracy at a reasonable cost (43).”
From Nightly sleep duration predicts grade point average in the first year of college (2023) · cites this paper as [43]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“however, a recent review into the use of Fitbit activity trackers suggests that steps are overestimated in free-living conditions [81].”
From Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis (2019) · cites this paper as [81]
In the citing paper
“using a modification of the modified Consensus-Based Standards for the Selection of Health Status Measurement Instruments (COSMIN) validation subscale used by Feehan et al [13] and an a priori modified COSMIN reliability subscale (Multimedia Appendix 2) to assess the quality and risk of bias of each study (EC and DF)”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [13]
In the citing paper
“Our interpretation of measurement accuracy was focused on acceptable limits of percentage difference of ±3% in controlled settings and percentage difference of ±10% in free-living settings, as outlined in previous work [13].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [13]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2010) · International Journal of Surgery · doi:10.1016/j.ijsu.2010.02.007 · Cited by 12,156
Mokkink, L. B., Terwee, C. B., Patrick, D. L., Alonso, J., Stratford, P. W., Knol, D. L., Bouter, L. M., & de Vet, H. C. W. (2010) · Quality of Life Research · doi:10.1007/s11136-010-9606-8 · Cited by 4,260 · cited 1×
“All articles were independently assessed for risk of bias by 2 independent reviewers (JG, CP) using a modification of the validation subscale from the checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments (Consensus-Based Standards for the Sele…”
MethodSteffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
Terwee, C. B., Mokkink, L. B., Knol, D. L., Ostelo, R. W. J. G., Bouter, L. M., & de Vet, H. C. W. (2012) · Quality of Life Research · doi:10.1007/s11136-011-9960-1 · Cited by 1,978 · cited 1×
“We rated each dimension as excellent, good, fair, or poor quality based on a priori modifications to the COSMIN validation subscale scoring criteria appropriate for accuracy studies (Multimedia Appendix 4) [16].”
MethodWhite Paper: “Walking Speed: the Sixth Vital Sign”
Fritz, S., & Lusardi, M. (2009) · Journal of Geriatric Physical Therapy · doi:10.1519/00139143-200932020-00002 · Cited by 1,390 · cited 1×
“When we further explored factors potentially influencing step count accuracy, we observed that accuracy of step count in controlled settings seemed to vary with speed of ambulation (jog, normal, self-paced, slow, or very slow) [50,51], with body placement (torso, wrist, or ankle), and with variations in how the body m…”
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 2×
“[Fitbit devices] and their ability to estimate steps, distance, physical activity, energy expenditure, and sleep” [11].”
BackgroundPedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752 · cited 2×
“We focused our interpretation of measurement accuracy based on predefined acceptable limits for measurement accuracy in controlled settings as a percentage difference of ±3% and acceptable limits for relative accuracy in free-living settings as a percentage difference of ±10% [19-22].”
MethodAccuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633 · cited 2×
“We focused our interpretation of measurement accuracy based on predefined acceptable limits for measurement accuracy in controlled settings as a percentage difference of ±3% and acceptable limits for relative accuracy in free-living settings as a percentage difference of ±10% [19-22].”
MethodHenriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · cited 3×
“A total of 3 studies (5 accuracy comparisons) reported sleep measurement accuracy in healthy young adults in free-living settings comparing a Fitbit device worn on the wrist with a SenseWear or Actiwatch accelerometer also worn on the wrist (Multimedia Appendix 3) [56,81,85].”
BackgroundValidity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 1×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundReliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360 · cited 2×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundAccuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336
Validation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 321 · cited 2×
“There were 2 studies (17 accuracy comparisons) examining Fitbit device distance measurement accuracy in a controlled setting in healthy young adults (Multimedia Appendix 3) [33,48].”
BackgroundMantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314
Behavior Change Techniques Present in Wearable Activity Trackers: A Critical Analysis
Mercer, K., Li, M., Giangregorio, L., Burns, C., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4461 · Cited by 304
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301 · cited 1×
“A total of 3 studies examined sleep in controlled settings (12 accuracy comparisons), comparing a Fitbit worn on the wrist against reference-standard polysomnography over 1 night of sleeping in a laboratory (Multimedia Appendix 3) [82-84].”
BackgroundTwenty-four Hours of Sleep, Sedentary Behavior, and Physical Activity with Nine Wearable Devices
ROSENBERGER, M. E., BUMAN, M. P., HASKELL, W. L., MCCONNELL, M. V., & CARSTENSEN, L. L. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000778 · Cited by 295
Noah, B., Keller, M. S., Mosadeghi, S., Stein, L., Johl, S., Delshad, S., Tashjian, V. C., Lew, D., Kwan, J. T., Jusufagic, A., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0002-4 · Cited by 273 · cited 1×
“Although designed as a consumer product to help motivate individuals to be physically active, Fitbit devices are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform patient–health professional interactions [3-7].”
BackgroundDooley, E. E., Golaszewski, N. M., & Bartholomew, J. B. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7043 · Cited by 242
A Primer on the Use of Equivalence Testing for Evaluating Measurement Agreement
DIXON, P. M., SAINT-MAURICE, P. F., KIM, Y., HIBBING, P., BAI, Y., & WELK, G. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001481 · Cited by 227 · cited 1×
“To be included in the final review, studies had to have extractable data for one or more of the following accuracy analyses: group mean or percentage differences, mean or median absolute percentage error (MAPE), or level-of-agreement analyses [14].”
MethodReliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed
FOKKEMA, T., KOOIMAN, T. J. M., KRIJNEN, W. P., VAN DER SCHANS, C. P., & DE GROOT, M. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001146 · Cited by 212 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundValidity of Consumer-Based Physical Activity Monitors for Specific Activity Types
NELSON, M. B., KAMINSKY, L. A., DICKIN, D. C., & MONTOYE, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 205
Murakami, H., Kawakami, R., Nakae, S., Nakata, Y., Ishikawa-Takata, K., Tanaka, S., & Miyachi, M. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2016.0152 · Cited by 204
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202
Current State of Commercial Wearable Technology in Physical Activity Monitoring 2015-2017
Bunn, J., Navalta, J. W., Fountaine, C. J., & Reece, J. (2018) · International Journal of Exercise Science · doi:10.70252/njqx2719 · Cited by 194 · cited 1×
“Although designed as a consumer product to help motivate individuals to be physically active, Fitbit devices are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform patient–health professional interactions [3-7].”
BackgroundAccuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundTully, M. A., McBride, C., Heron, L., & Hunter, R. F. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-952 · Cited by 172
Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
Paul, S. S., Tiedemann, A., Hassett, L. M., Ramsay, E., Kirkham, C., Chagpar, S., & Sherrington, C. (2015) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000013 · Cited by 164
Alharbi, M., Bauman, A. E., Neubeck, L., & Gallagher, R. D. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316634883 · Cited by 158 · cited 1×
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundWearable Technology and Physical Activity in Chronic Disease: Opportunities and Challenges
Phillips, S. M., Cadmus‐Bertram, L., Rosenberg, D. E., Buman, M. P., & Lynch, B. M. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2017.08.015 · Cited by 155 · cited 1×
“Although designed as a consumer product to help motivate individuals to be physically active, Fitbit devices are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform patient–health professional interactions [3-7].”
BackgroundSushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161224 · Cited by 152
Reid, R. E. R., Insogna, J. A., Carver, T. E., Comptour, A. M., Bewski, N. A., Sciortino, C. D., & Andersen, R. E. (2016) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2016.10.015 · Cited by 152 · cited 1×
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundComparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149 · cited 1×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundHow valid are wearable physical activity trackers for measuring steps?
An, H., Jones, G. C., Kang, S., Welk, G. J., & Lee, J. M. (2016) · European Journal of Sport Science · doi:10.1080/17461391.2016.1255261 · Cited by 149 · cited 1×
“Our evaluation for step count accuracy in free-living settings was consistent with those of 5 other studies examining MAPE or level-of-agreement differences in daily step measures in healthy adults for Fitbit compared with an accelerometer worn on the torso or a pedometer worn on the ankle [42,64-67].”
ResultValidity of Different Activity Monitors to Count Steps in an Inpatient Rehabilitation Setting
Treacy, D., Hassett, L. M., Schurr, K., Chagpar, S., Paul, S. S., & Sherrington, C. (2017) · Physical Therapy · doi:10.1093/ptj/pzx010 · Cited by 145 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundÉvaluation de la qualité des podomètres commerciaux
Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A. (2006) · Canadian Journal of Public Health · doi:10.1007/bf03405359 · Cited by 142
Campbell, M., Katikireddi, S. V., Sowden, A., McKenzie, J. E., & Thomson, H. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-020064 · Cited by 142
Wahl, Y., Düking, P., Droszez, A., Wahl, P., & Mester, J. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00725 · Cited by 133
A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitors
Dannecker, K. L., Sazonova, N. A., Melanson, E. L., Sazonov, E. E., & Browning, R. C. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318299d2eb · Cited by 131 · cited 1×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundChu, A. H. Y., Ng, S. H.-X., Paknezhad, M., Gauterin, A., Koh, D. S. Q., Brown, M. S., & Müller‐Riemenschneider, F. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172535 · Cited by 131
Validity of FitBit, Jawbone UP, Nike+ and other wearable devices for level and stair walking
Huang, Y., Xu, J., Yu, B., & Shull, P. B. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.04.025 · Cited by 129 · cited 2×
“There were 2 studies (17 accuracy comparisons) examining Fitbit device distance measurement accuracy in a controlled setting in healthy young adults (Multimedia Appendix 3) [33,48].”
BackgroundImboden, M. T., Nelson, M. B., Kaminsky, L. A., & Montoye, A. H. K. (2017) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-096990 · Cited by 128 · cited 2×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundValidation of the Fitbit Wireless Activity Tracker for Prediction of Energy Expenditure
Sasaki, J. E., Hickey, A., Mavilia, M. G., Tedesco, J., John, D., Keadle, S. K., & Freedson, P. S. (2014) · Journal of Physical Activity and Health · doi:10.1123/jpah.2012-0495 · Cited by 120 · cited 1×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundVooijs, M., Alpay, L., Snoeck-Stroband, J. B., Beerthuizen, T., Siemonsma, P. C., Abbink, J. J., Sont, J. K., & Rövekamp, T. (2014) · Interactive Journal of Medical Research · doi:10.2196/ijmr.3056 · Cited by 119 · cited 1×
“Fitbit devices, and particularly the wrist-worn devices, have demonstrated dependability, durability, and acceptability [9,10].”
BackgroundChowdhury, E. A., Western, M. J., Nightingale, T. E., Peacock, O. J., & Thompson, D. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171720 · Cited by 118
Floegel, T. A., Flórez-Pregonero, A., Hekler, E. B., & Buman, M. P. (2016) · The Journals of Gerontology Series A · doi:10.1093/gerona/glw098 · Cited by 114 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundDominick, G. M., Winfree, K. N., Pohlig, R. T., & Papas, M. A. (2016) · JMIR mhealth and uhealth · doi:10.2196/mhealth.6281 · Cited by 114
Cook, J. D., Prairie, M. L., & Plante, D. T. (2017) · Journal of Affective Disorders · doi:10.1016/j.jad.2017.04.030 · Cited by 113 · cited 2×
“On the other hand, 1 study examined total sleep time and sleep efficiency in the sensitive sleep mode, reporting Fitbit underestimation of both by more than 15% [82].”
BackgroundLee, H. A., Lee, H., Moon, J.-H., Lee, T., Kim, M.-G., In, H., Cho, C., & Kim, L. (2017) · Psychiatry Investigation · doi:10.4306/pi.2017.14.2.179 · Cited by 107 · cited 2×
“A total of 3 studies (5 accuracy comparisons) reported sleep measurement accuracy in healthy young adults in free-living settings comparing a Fitbit device worn on the wrist with a SenseWear or Actiwatch accelerometer also worn on the wrist (Multimedia Appendix 3) [56,81,85].”
BackgroundMethodBrewer, W., Swanson, B. T., & Ortíz, A. (2017) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2017-000254 · Cited by 99
Gomersall, S. R., Ng, N., Burton, N. W., Pavey, T., Gilson, N. D., & Brown, W. J. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5531 · Cited by 98
Chow, J. J., Thom, J. M., Wewege, M. A., Ward, R. E., & Parmenter, B. J. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.012 · Cited by 92 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundSimpson, L. A., Eng, J. J., Klassen, T. D., Lim, S. B., Louie, D. R., Parappilly, B., Sakakibara, B. M., & Zbogar, D. (2015) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-1993 · Cited by 91 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundKlassen, T. D., Simpson, L. A., Lim, S. B., Louie, D. R., Parappilly, B., Sakakibara, B. M., Zbogar, D., & Eng, J. J. (2015) · Physical Therapy · doi:10.2522/ptj.20140611 · Cited by 90 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundAccuracy of Wristband Activity Monitors during Ambulation and Activities
CHEN, M.-D., KUO, C.-C., PELLEGRINI, C. A., & HSU, M.-J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000984 · Cited by 90 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundPrice, K. J., Bird, S. R., Lythgo, N., Raj, I. S., Wong, J., & Lynch, C. (2016) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1253795 · Cited by 88 · cited 1×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundConcurrent Validity of Wearable Activity Trackers Under Free-Living Conditions
Brooke, S. M., An, H.-S., Kang, S.-K., Noble, J. M., Berg, K. E., & Lee, J.-M. (2017) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001571 · Cited by 79 · cited 2×
“A total of 3 studies (5 accuracy comparisons) reported sleep measurement accuracy in healthy young adults in free-living settings comparing a Fitbit device worn on the wrist with a SenseWear or Actiwatch accelerometer also worn on the wrist (Multimedia Appendix 3) [56,81,85].”
BackgroundLi, L. C., Sayre, E. C., Xie, H., Clayton, C., & Feehan, L. M. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7863 · Cited by 74 · cited 1×
“Furthermore, our findings do not negate the value of using Fitbit activity trackers in the manner for which the devices were intended, which is for self-monitoring of physical activity patterns and motivating individuals to achieve their physical activity goals [88-91].”
BackgroundSelf-citationLI, L. C., Sayre, E. C., Xie, H., Falck, R. S., Best, J. R., Liu-Ambrose, T. Y. L., Grewal, N., Hoens, A. M., Noonan, G., & Feehan, L. M. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.8514 · Cited by 71
Self-citationBassett, D. R., Mahar, M. T., Rowe, D. A., & Morrow, J. R. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31817c699c · Cited by 70 · cited 2×
“We focused our interpretation of measurement accuracy based on predefined acceptable limits for measurement accuracy in controlled settings as a percentage difference of ±3% and acceptable limits for relative accuracy in free-living settings as a percentage difference of ±10% [19-22].”
MethodRosenberg, D. E., Kadokura, E., Bouldin, E. D., Miyawaki, C. E., Higano, C. S., & Hartzler, A. L. (2016) · PubMed · doi:10.71889/5fylantbak.30789662 · Cited by 67
Balto, J. M., Kinnett-Hopkins, D., & Motl, R. W. (2016) · Multiple Sclerosis Journal - Experimental Translational and Clinical · doi:10.1177/2055217316634754 · Cited by 66 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundGusmer, R., Bosch, T. A., Watkins, A. N., Ostrem, J. D., & Dengel, D. R. (2014) · The Open Sports Medicine Journal · doi:10.2174/1874387001408010011 · Cited by 63
An Evaluation of Commercial Pedometers for Monitoring Slow Walking Speed Populations
Beevi, F. H. A., Miranda, J., Pedersen, C. F., & Wagner, S. (2015) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0120 · Cited by 62 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundMobile Device Accuracy for Step Counting Across Age Groups
Modave, F. P., Guo, Y. M., Bian, J., Gurka, M. J., Parish, A., Smith, M. D., Lee, A. M., & Buford, T. W. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.7870 · Cited by 62
Step count accuracy and reliability of two activity tracking devices in people after stroke
Schaffer, S. D., Holzapfel, S. D., Fulk, G., & Bosch, P. R. (2017) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2017.1354412 · Cited by 54 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundThorup, C. B., Andreasen, J. J., Sørensen, E. E., Grønkjær, M., Dinesen, B., & Hansen, J. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-011742 · Cited by 49 · cited 1×
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundThe Validity of Consumer-Level Activity Monitors in Healthy Older Adults in Free-Living Conditions
Farina, N., & Lowry, R. (2017) · Journal of Aging and Physical Activity · doi:10.1123/japa.2016-0344 · Cited by 49 · cited 1×
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundThe bit doesn’t fit: Evaluation of a commercial activity-tracker at slower walking speeds
Wong, C. K., Mentis, H. M., & Kuber, R. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.010 · Cited by 46 · cited 2×
“Measurement accuracy, or how close to “true” the measured value is, is an important consideration, as Fitbit devices are being used as an outcome measurement tool in research and to inform health care decisions [12,13].”
BackgroundPark, W., Lee, V. J., Ku, B., & Tanaka, H. (2014) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2014.01.003 · Cited by 43 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundWhen a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors
O’Connell, S., OLaighin, G. M., & Quinlan, L. R. (2017) · PLoS ONE · doi:10.1371/journal.pone.0169616 · Cited by 42
The Fitbit One Physical Activity Tracker in Men With Prostate Cancer: Validation Study
Blarigan, E. L. V., Kenfield, S. A., Tantum, L. K., Cadmus‐Bertram, L., Carroll, P. R., & Chan, J. M. (2017) · JMIR Cancer · doi:10.2196/cancer.6935 · Cited by 42
Montoye, A. H. K., Mitrzyk, J. R., & Molesky, M. J. (2017) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2017.1331166 · Cited by 40 · cited 1×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundValidity of the Fitbit One for Measuring Activity in Community-Dwelling Stroke Survivors
Hui, J., Heyden, R., Bao, T., Accettone, N., McBay, C., Richardson, J. A., & Tang, A. (2017) · Physiotherapy Canada · doi:10.3138/ptc.2016-40.ep · Cited by 39 · cited 1×
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundA Comparison of Accelerometer Accuracy in Older Adults
Phillips, L. J., Petroski, G. F., & Markis, N. E. (2015) · Research in Gerontological Nursing · doi:10.3928/19404921-20150429-03 · Cited by 35 · cited 1×
“A total of 27 studies (191 accuracy comparisons) examined Fitbit device step measurements compared with a reference-standard criterion of direct observation and counting of steps in a controlled setting (Multimedia Appendix 3) [12,24-49].”
BackgroundA practical validation study of a commercial accelerometer using good and poor sleepers
Dickinson, D. L., Cazier, J. A., & Cech, T. G. (2016) · Health Psychology Open · doi:10.1177/2055102916679012 · Cited by 34 · cited 1×
“These findings are consistent with those of 2 other studies reporting Fitbit overestimations of sleeping time compared with a portable sleep monitor (MAPE approximately 10%) or Actiwatch accelerometer (approximately 10 minutes per night) [66,86].”
ResultComparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30 · cited 3×
“These findings are consistent with those of 2 other accuracy studies reporting Fitbit underestimations of daily energy expenditure, with MAPE values varying from 16% to 30% for Fitbit devices compared with measurements from an ActiGraph or Actiheart accelerometer [58,70].”
BackgroundResultValidation of the Fitbit One® for physical activity measurement at an upper torso attachment site
Diaz, K. M., Krupka, D. J., Chang, M. J., Shaffer, J. A., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2016) · BMC Research Notes · doi:10.1186/s13104-016-2020-8 · Cited by 29 · cited 2×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundO’Connell, S., OLaighin, G. M., Kelly, L. S., Murphy, E., Beirne, S., Burke, N., Kilgannon, O., & Quinlan, L. R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154956 · Cited by 28
A Validation Study of the Fitbit One in Daily Life Using Different Time Intervals
Middelweerd, A., van der Ploeg, H. P., van Halteren, A., Twisk, J. W. R., Brug, J., & Velde, S. J. T. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001225 · Cited by 28 · cited 1×
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundComparative accuracy of fitness tracking modalities in quantifying energy expenditure
Dondzila, C. J., & Garner, D. P. (2016) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1197978 · Cited by 22 · cited 1×
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundThe accuracy of personal activity monitoring devices
Battenberg, A. K., Donohoe, S., Robertson, N. B., & Schmalzried, T. P. (2017) · Seminars in Arthroplasty JSES · doi:10.1053/j.sart.2017.07.006 · Cited by 18
LI, L. C., Feehan, L. M., Shaw, C., Xie, H. W., Sayre, E. C., Aviña-Zubeita, A., Grewal, N., Townsend, A. F., Gromala, D., Noonan, G., et al. (2017) · BMC Rheumatology · doi:10.1186/s41927-017-0005-4 · Cited by 15 · cited 1×
“Furthermore, our findings do not negate the value of using Fitbit activity trackers in the manner for which the devices were intended, which is for self-monitoring of physical activity patterns and motivating individuals to achieve their physical activity goals [88-91].”
Self-citationSystematic Review of mHealth Interventions Involving Fitbit Activity Tracking Devices
Mishra, A., Nieto, A., & Kitsiou, S. (2017) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi.2017.42 · Cited by 10 · cited 1×
“Although designed as a consumer product to help motivate individuals to be physically active, Fitbit devices are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform patient–health professional interactions [3-7].”
Background
Research works printed but not linked: 5
- Fitbit Reports $571M Q4’17 and $1.616B FY’17 Revenue201802262018-08-01fitbit.comhttps://investor.fitbit.com/press/press-releases/press-release-details/2018/Fitbit-Reports-571M-Q417-and-1616B-FY17-Revenue/default.aspx
- Rosenberg, D, 2016, AMIA Annu Symp Proc, 2016, 1050
- Popay, J, 2006, Guidance on the Conduct of Narrative Synthesis in Systematic Reviews. A Product From the ESRC Methods Programme. Version 1: April 2006
- Montes, J, 2017, J Exerc Physiol Online, 20, 134
- Stackpool, CM, 2014, J Fit Res, 3, 32
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“Studies with fewer than 10 participants were excluded, as has been done in previous work [13].”
BackgroundMethodResultInfluentialBrickwood, K.-J., Watson, G., O'Brien, J., & Williams, A. D. (2019) · JMIR mHealth and uHealth · doi:10.2196/11819 · Cited by 689
“however, a recent review into the use of Fitbit activity trackers suggests that steps are overestimated in free-living conditions [81].”
Tazreean, R., Nelson, G., & Twomey, R. (2022) · Journal of Comparative Effectiveness Research · doi:10.2217/cer-2021-0258 · Cited by 334
Wearable Devices in Cardiovascular Medicine
Hughes, A., Shandhi, M. M. H., Master, H., Dunn, J., & Brittain, E. (2023) · Circulation Research · doi:10.1161/circresaha.122.322389 · Cited by 291
Fitbit-based interventions for healthy lifestyle outcomes: systematic review and meta-analysis
Ringeval, M., Wagner, G., Denford, J., Paré, G., & Kitsiou, S. (2020) · Journal of Medical Internet Research · doi:10.2196/23954 · Cited by 225
“We focused on Fitbit devices because they are among the most accurate commercially available wearables [39-43] and are, in some cases, comparable to research-grade monitors [44].”
Result
Metadata
- Authors
- Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C.
- Affiliations
- University of British Columbia (CA)
- Corresponding author
- Feehan, Lynne M
- ORCID
- Venue
- JMIR mHealth and uHealth
- Publisher
- JMIR Publications Inc.
- Published
- 2018-08-09
- Volume
- 6
- Issue
- 8
- Pages
- e10527
- ISSN
- 2291-5222 (ISSN-L)
- PMC
- PMC6107736
- OpenAlex
- W2883411829
- Semantic Scholar
- 2a26625e52767429985e16a354821d08a66c5799
- Cited by
- 616
- References
- 86
- Citations by year
- 2026: 69 · 2025: 72 · 2024: 86 · 2023: 62 · 2022: 84 · 2021: 80 · 2020: 130 · 2019: 30 · 2018: 2
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR mhealth and uhealth (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Simon Fraser University
- Canadian Institutes of Health Research (316595)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- Fitbit, wearable activity trackers, wearable devices, measurement accuracy, step count, energy expenditure, sleep monitoring, distance measurement, accelerometer, free-living conditions, physical activity measurement, health promotion research, consumer health technology, measurement bias, adults with disabilities, healthy adults, healthcare decision-making
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.