Usefulness of Modern Activity Trackers for Monitoring Exercise Behavior in Chronic Cardiac Patients: Validation Study
Open accessAbstract
Background: Improving physical activity (PA) is a core component of secondary prevention and cardiac (tele)rehabilitation. Commercially available activity trackers are frequently used to monitor and promote PA in cardiac patients. However, studies on the validity of these devices in cardiac patients are scarce. As cardiac patients are being advised and treated based on PA parameters measured by these devices, it is highly important to evaluate the accuracy of these parameters in this specific population. Objective: The aim of this study was to determine the accuracy and responsiveness of 2 wrist-worn activity trackers, Fitbit Charge 2 (FC2) and Mio Slice (MS), for the assessment of energy expenditure (EE) in cardiac patients. Methods: EE assessed by the activity trackers was compared with indirect calorimetry (Oxycon Mobile [OM]) during a laboratory activity protocol. Two groups were assessed: patients with stable coronary artery disease (CAD) with preserved left ventricular ejection fraction (LVEF) and patients with heart failure with reduced ejection fraction (HFrEF). Results: A total of 38 patients were included: 19 with CAD and 19 with HFrEF (LVEF 31.8%, SD 7.6%). The CAD group showed no significant difference in total EE between FC2 and OM (47.5 kcal, SD 112 kcal; P=.09), in contrast to a significant difference between MS and OM (88 kcal, SD 108 kcal; P=.003). The HFrEF group showed significant differences in EE between FC2 and OM (38 kcal, SD 57 kcal; P=.01), as well as between MS and OM (106 kcal, SD 167 kcal; P=.02). Agreement of the activity trackers was low in both groups (CAD: intraclass correlation coefficient [ICC] FC2=0.10, ICC MS=0.12; HFrEF: ICC FC2=0.42, ICC MS=0.11). The responsiveness of FC2 was poor, whereas MS was able to detect changes in cycling loads only. Conclusions: Both activity trackers demonstrated low accuracy in estimating EE in cardiac patients and poor performance to detect within-patient changes in the low-to-moderate exercise intensity domain. Although the use of activity trackers in cardiac patients is promising and could enhance daily exercise behavior, these findings highlight the need for population-specific devices and algorithms.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Many validation studies have questioned the accuracy of raw sensor data and software algorithms.
“Many validation studies have questioned the accuracy of raw sensor data and software algorithms92–94.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [94]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Cicchetti, D. V. (1994) · Psychological Assessment · doi:10.1037/1040-3590.6.4.284 · Cited by 9,349 · cited 1× · see citing works
“An ICC below 0.4 was considered poor, between 0.4 and 0.59 fair, between 0.6 and 0.74 good, and above 0.75 was considered as excellent reliability [34].”
BackgroundInfluentialNew methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,608 · see citing works
Mokkink, L. B., Terwee, C. B., Patrick, D. L., Alonso, J., Stratford, P. W., Knol, D. L., Bouter, L. M., & de Vet, H. C. W. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.02.006 · Cited by 4,465 · see citing works
Kim, H.-Y. (2013) · Restorative Dentistry & Endodontics · doi:10.5395/rde.2013.38.1.52 · Cited by 4,035 · see citing works
Exercise-Based Cardiac Rehabilitation for Coronary Heart Disease
Anderson, L., Oldridge, N., Thompson, D. R., Zwisler, A.-D., Rees, K., Martin, N., & Taylor, R. S. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.10.044 · Cited by 1,910 · see citing works
Cardiac Rehabilitation and Secondary Prevention of Coronary Heart Disease
Ades, P. A. (2001) · New England Journal of Medicine · doi:10.1056/nejmra001529 · Cited by 765 · see citing works
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625 · see citing works
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616 · see citing works
Piepoli, M. F., Corrà, U., Adamopoulos, S. N., Benzer, W., Bjarnason‐Wehrens, B., Cupples, M., Dendale, P., Doherty, P., Gaiță, D. I., Höfer, S., et al. (2012) · European Journal of Preventive Cardiology · doi:10.1177/2047487312449597 · Cited by 592 · see citing works
Outliers in process modeling and identification
Pearson, R. K. (2002) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.974338 · Cited by 502 · see citing works
Recommendations for improved data processing from expired gas analysis indirect calorimetry
Robergs, R. A., Dwyer, D., & Astorino, T. (2010) · Sports Medicine · doi:10.2165/11319670-000000000-00000 · Cited by 356 · see citing works
Understanding the meaning of accuracy, trueness and precision
Menditto, A., Patriarca, M., & Magnusson, B. (2006) · Accreditation and Quality Assurance · doi:10.1007/s00769-006-0191-z · Cited by 344 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
Stahl, S. E., An, H.-S., Dinkel, D. M., Noble, J. M., & Lee, J.-M. (2016) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000106 · Cited by 276 · see citing works
Dooley, E. E., Golaszewski, N. M., & Bartholomew, J. B. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7043 · Cited by 242 · see citing works
A review of telerehabilitation for cardiac patients
Frederix, I., Vanhees, L., Dendale, P., & Goetschalckx, K. (2014) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x14562732 · Cited by 194 · see citing works
Using an electronic activity monitor system as an intervention modality: A systematic review
Lewis, Z. H., Lyons, E., Jarvis, J. M., & Baillargeon, J. (2015) · BMC Public Health · doi:10.1186/s12889-015-1947-3 · Cited by 183 · see citing works
Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method
Rosdahl, H. G., Gullstrand, L., Eriksson, J. S., Johansson, P., & Schantz, P. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1326-9 · Cited by 181 · see citing works
Dalal, H. M., Taylor, R. S., Jolly, K. B., Davis, R., Doherty, P., Miles, J., van Lingen, R., Warren, F. C., Green, C., Wingham, J., et al. (2018) · European Journal of Preventive Cardiology · doi:10.1177/2047487318806358 · Cited by 177 · see citing works
Frederix, I., Solmi, F., Piepoli, M. F., & Dendale, P. (2017) · European Journal of Preventive Cardiology · doi:10.1177/2047487317732274 · Cited by 172 · see citing works
Evaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148 · see citing works
Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR
Bai, Y., Hibbing, P. R., Mantis, K., & Welk, G. J. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1412235 · Cited by 147 · see citing works
Relation of daily activity levels in patients with chronic heart failure to long-term prognosis
Walsh, J. T., Charlesworth, A., Andrews, R. V., Hawkins, M., & Cowley, A. J. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00141-0 · Cited by 144 · see citing works
Alharbi, M., Bauman, A. E., Neubeck, L., & Gallagher, R. D. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316634883 · Cited by 142 · see citing works
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139 · see citing works
Chowdhury, E. A., Western, M. J., Nightingale, T. E., Peacock, O. J., & Thompson, D. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171720 · Cited by 118 · see citing works
Smith, K. M., Arthur, H. M., McKelvie, R. S., & Kodis, J. A. (2004) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/01.hjr.0000136414.40017.10 · Cited by 103 · see citing works
Smith, K. M., McKelvie, R. S., Thorpe, K. E., & Arthur, H. M. (2011) · Heart · doi:10.1136/hrt.2010.202036 · Cited by 90 · see citing works
Price, K. J., Bird, S. R., Lythgo, N., Raj, I. S., Wong, J., & Lynch, C. (2016) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1253795 · Cited by 87 · see citing works
Prince, S. A., Blanchard, C. M., Grace, S. L., & Reid, R. D. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487315617101 · Cited by 83 · see citing works
ter Hoeve, N., Huisstede, B. M. A., Stam, H. J., van Domburg, R. T., Sunamura, M., & van den Berg-Emons, R. J. G. (2014) · Physical Therapy · doi:10.2522/ptj.20130509 · Cited by 72 · see citing works
van den Berg-Emons, H. (., Bussmann, J. B. J., Balk, A. H. M. M., Keijzer-Oster, D., & Stam, H. J. (2001) · Physical Therapy · doi:10.1093/ptj/81.9.1502 · Cited by 67 · see citing works
Gusmer, R., Bosch, T. A., Watkins, A. N., Ostrem, J. D., & Dengel, D. R. (2014) · The Open Sports Medicine Journal · doi:10.2174/1874387001408010011 · Cited by 59 · see citing works
ter Hoeve, N., Sunamura, M., Stam, H. J., Boersma, E. H., Geleijnse, M. L., van Domburg, R. T., & van den Berg-Emons, R. J. G. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.12.015 · Cited by 59 · see citing works
Exercise training programs in Dutch cardiac rehabilitation centres
Vromen, T., Spee, R. F., Kraal, J. J., Peek, N. B., van Engen-Verheul, M. M., Kraaijenhagen, R. A., Gijsbers, H., & Kemps, H. (2013) · Netherlands Heart Journal · doi:10.1007/s12471-013-0374-2 · Cited by 35 · see citing works
Self-citationvan den Berg-Emons, R. J. G., Bussmann, J. B. J., Balk, A. H. M. M., & Stam, H. J. (2005) · Physical Therapy · doi:10.1093/ptj/85.12.1340 · Cited by 34 · see citing works
Kraal, J. J., Sartor, F., Papini, G. B., Stut, W. J. J., Peek, N. B., Kemps, H., & Bonomi, A. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316667786 · Cited by 21 · see citing works
Self-citation2014 European Society of Cardiology Guidelines on Hypertrophic Cardiomyopathy
Özdemir, M. (2014) · Turk Kardiyoloji Dernegi Arsivi-Archives of the Turkish Society of Cardiology · doi:10.5543/tkda.2014.34984 · Cited by 16 · see citing works
de Vet, H. C. W., Terwee, C. B., Mokkink, L. B., et al. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9780511996214.008 · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829 · see citing works
Jensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93 · see citing works
Self-citation
- Authors
- Herkert, C., Kraal, J. J., van Loon, E. M. A., van Hooff, M., & Kemps, H. M. C.
- Corresponding author
- Herkert, Cyrille
- ORCID
- Venue
- JMIR mHealth and uHealth
- Publisher
- JMIR Publications Inc.
- Published
- 2019-12-19
- Volume
- 7
- Issue
- 12
- Pages
- e15045
- ISSN
- 2291-5222 (ISSN-L)
- PMC
- PMC6940867
- OpenAlex
- W2995874039
- Cited by
- 19
- References
- 39
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 4 · 2023: 3 · 2022: 3 · 2021: 2 · 2020: 2
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR mhealth and uhealth (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- wearable activity trackers, energy expenditure, cardiac patients, heart failure with reduced ejection fraction, coronary artery disease, device validation, indirect calorimetry, cardiac rehabilitation, secondary prevention
- MeSH terms
- Fitness Trackers, Wearable Electronic Devices, Aged, Calorimetry, Indirect, Coronary Artery Disease, Energy Metabolism, Female, Heart Diseases, Heart Failure, Humans, Male, Middle Aged, Monitoring, Physiologic, Stroke Volume, Exercise, Case-Control Studies, Ventricular Function, Left, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review