Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Open accessPublished version of a preprint
The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.
Abstract
Background: Wearable sleep monitors are of high interest to consumers and researchers because of their ability to provide estimation of sleep patterns in free-living conditions in a cost-efficient way. Objective: We conducted a systematic review of publications reporting on the performance of wristband Fitbit models in assessing sleep parameters and stages. Methods: In adherence with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement, we comprehensively searched the Cumulative Index to Nursing and Allied Health Literature (CINAHL), Cochrane, Embase, MEDLINE, PubMed, PsycINFO, and Web of Science databases using the keyword Fitbit to identify relevant publications meeting predefined inclusion and exclusion criteria. Results: The search yielded 3085 candidate articles. After eliminating duplicates and in compliance with inclusion and exclusion criteria, 22 articles qualified for systematic review, with 8 providing quantitative data for meta-analysis. In reference to polysomnography (PSG), nonsleep-staging Fitbit models tended to overestimate total sleep time (TST; range from approximately 7 to 67 mins; effect size=-0.51, P<.001; heterogenicity: I2=8.8%, P=.36) and sleep efficiency (SE; range from approximately 2% to 15%; effect size=-0.74, P<.001; heterogenicity: I2=24.0%, P=.25), and underestimate wake after sleep onset (WASO; range from approximately 6 to 44 mins; effect size=0.60, P<.001; heterogenicity: I2=0%, P=.92) and there was no significant difference in sleep onset latency (SOL; P=.37; heterogenicity: I2=0%, P=.92). In reference to PSG, nonsleep-staging Fitbit models correctly identified sleep epochs with accuracy values between 0.81 and 0.91, sensitivity values between 0.87 and 0.99, and specificity values between 0.10 and 0.52. Recent-generation Fitbit models that collectively utilize heart rate variability and body movement to assess sleep stages performed better than early-generation nonsleep-staging ones that utilize only body movement. Sleep-staging Fitbit models, in comparison to PSG, showed no significant difference in measured values of WASO (P=.25; heterogenicity: I2=0%, P=.92), TST (P=.29; heterogenicity: I2=0%, P=.98), and SE (P=.19) but they underestimated SOL (P=.03; heterogenicity: I2=0%, P=.66). Sleep-staging Fitbit models showed higher sensitivity (0.95-0.96) and specificity (0.58-0.69) values in detecting sleep epochs than nonsleep-staging models and those reported in the literature for regular wrist actigraphy. Conclusions: Sleep-staging Fitbit models showed promising performance, especially in differentiating wake from sleep. However, although these models are a convenient and economical means for consumers to obtain gross estimates of sleep parameters and time spent in sleep stages, they are of limited specificity and are not a substitute for PSG.
Overview
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Flow diagram adapted from Moher et al [14] describing the search strategy of databases to retrieve and qualify publications of relevance for review.](https://figures.cochat.ai/paper-figures/9b8cc8142bdb4533868e38b2aac9f794/accuracy-of-wristband-fitbit-models-in-assessing-sleep-systematic-review-and-figure-1.jpg)




Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The present study used wrist actigraphy Fitbits to track sleep patterns, which may underestimate total nightly sleep by 7 to 67 min (41), suggesting that students in the present samples may have been sleeping more than the estimates by wrist actigraphy suggest.”
From Nightly sleep duration predicts grade point average in the first year of college (2023) · cites this paper as [41]
In the citing paper
“The potential role of new technologies, like smartphone‐based applications (Ko et al., 2015) and consumer‐focused wearable devices (Haghayegh et al., 2019), are not yet sufficiently elaborated, and healthcare systems often do not integrate objective information provided by the patient from self‐made home recordings such as from smartphone applications.”
From Obstructive sleep apnea: transition from pathophysiology to an integrative disease model (2022) · cites this paper as Haghayegh et al., 2019
In the citing paper
“According to a recent meta-analysis, sleep-staging Fitbit devices, such as the Charge 2, showed no significant difference in measured values of WASO, TST, and SE, but they slightly underestimated SOL in comparison to the gold standard PSG [45].”
From Digital Biomarkers for Depression Screening With Wearable Devices: Cross-sectional Study With Machine Learning Modeling (2021) · cites this paper as [45]
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 2×
“As recommended, the threshold probability of 10% ( P =.10) was the basis for testing the significance of heterogenicity and also for determining statistical significance of subgroup comparisons [20,21].”
Wang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2009) · doi:10.1002/9780470743386 · Cited by 14,225 · cited 2×
“Overall effect size and 95% prediction interval for each parameter per nonsleep-staging and sleep-staging Fitbit models were calculated using a random-effects model [17,18].”
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Using Effect Size—or Why the P Value Is Not Enough
Sullivan, G. M., & Feinn, R. (2012) · Journal of Graduate Medical Education · doi:10.4300/jgme-d-12-00156.1 · Cited by 5,553 · cited 1×
“Effect size values of 0.2, 0.5, and 0.8 are considered small, medium, and large effects, respectively [19].”
InfluentialThe “All of Us” Research Program
The All of Us Research Program Investigators (2019) · New England Journal of Medicine · doi:10.1056/nejmsr1809937 · Cited by 2,440
Plea for routinely presenting prediction intervals in meta-analysis.
IntHout, J., Ioannidis, J. P. A., Rovers, M. M., & Goeman, J. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010247 · Cited by 2,264 · cited 1×
“Overall effect size and 95% prediction interval for each parameter per nonsleep-staging and sleep-staging Fitbit models were calculated using a random-effects model [17,18].”
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415 · cited 1×
“These are very promising results, since the major drawback of body activity and movement-based trackers, such as actigraphs, is overestimation of sleep time and poor sensitivity of detecting WASO (ie, poor differentiation of wake from sleep epochs during spans of quiet bedtime activity) [45,47].”
Research works printed but not linked: 2
- Wright, SP, 2017, FASEB J, 31, 1
- CoeRIt's the effect size, stupid: What effect size is and why it is importantProceedings of the Annual Conference of the British Educational Research Association2002Annual Conference of the British Educational Research AssociationSeptember 12-14, 2002University of Exeter, UK
Cited by
Items 201–300 of 470
Griffiths, C., Walker, K., Willis, A., & Pollard, L. (2022) · Mental Health Review Journal · doi:10.1108/mhrj-04-2021-0036 · Cited by 11
Snoozing: an examination of a common method of waking
Mattingly, S. M., Martinez, G. J., Young, J., Cain, M. K., & Striegel, A. (2022) · SLEEP · doi:10.1093/sleep/zsac184 · Cited by 10
“For a meta-analysis of commercially available wearable accuracy, see [51].”
Pandrangi, V. C., Jorizzo, M., Shah, S. N., Bruening, J., Wax, M. K., Clayburgh, D. R., Andersen, P. E., & Li, R. J. (2022) · Head & Neck · doi:10.1002/hed.27182 · Cited by 10
“69) in evaluating sleep stages.(28) In our study, it is possible that sleep measurements are over or underestimated, but our study also demonstrated TST correlated with subjective sleep scores.”
MethodResultHassinger, A. B., Velez, C., Wang, J., Mador, M. J., Wilding, G. E., & Mishra, A. (2023) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10820 · Cited by 9
“Fitbits have been shown to lack accuracy compared to polysomnography, with total sleep time 39 including overestimation 40 and underestimation 41 as well as difficulty capturing sleep stages.”
Clinical utility of smartphone applications for sleep physicians
Hathorn, T., Byun, Y. J., Rosen, R., & Sharma, A. (2023) · Sleep and Breathing · doi:10.1007/s11325-023-02851-y · Cited by 8
“FitBit and its sleep-tracking software have multiple validation studies with a systematic review of 22 articles published in 2019 [21].”
MethodSaavedra, J. U., Deaso, E. A., Austin, M., Cadavid, L., Kraff, R., & Knowles, E. E. M. (2025) · JMIR Formative Research · doi:10.2196/66187 · Cited by 9
“Fourth, while fitbit is a cost-effective way to collect sleep and activity information, it may overestimate sleep time (particularly sleep staging estimates [73,74] and activity levels [75] compared with gold standard methods (eg, polysomnography for sleep).”
Wang, Y., Zhao, Z., Zhang, M., Zhang, Y., Yan, J., Jelsma, E. B., Cham, H., Alegria, M. M., & Yip, T. (2025) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2024.12.004 · Cited by 8
Yang, J., Xu, D., Lu, H., Yin, X., Song, H., Zong, W., Xu, D., Lu, X., Wei, L., Zhu, H., et al. (2025) · Nature and Science of Sleep · doi:10.2147/nss.s537489 · Cited by 8
“…are at night and the longer they stay awake, the greater the measurement errors of the device, consistent with the results of Hamill et al 8,14,29,30 On this basis, qualitative research serves as a supplement to quantitative research, fully revealing the pathway of sleep fragmentation →…”
Park, S. Y., Lee, J.-B., Lee, T., Jeong, H. Y., Kim, S. Y., & Jeon, S. Y. (2025) · BMC Geriatrics · doi:10.1186/s12877-025-06316-7 · Cited by 8
“For example, Fitbit devices objectively estimate sleep patterns [29, 30], and Heart rate data, including circadian rhythms of heart rate (CHR), can be obtained using photoplethysmogra-phy sensors embedded in the device [31, 32].”
Yamakawa, M., Kang, H. S., Wang, H., & Konno, R. (2024) · International Journal of Nursing Practice · doi:10.1111/ijn.13240 · Cited by 10
OSAHS Detection Capabilities of RingConn Smart Ring: A Feasibility Study
Guo, H., Wu, H., Xia, J., Cheng, Y., Guo, Q., Chen, Y., Xu, T., Wang, J., & Wang, G. (2024) · IEEE International Conference on Artificial Intelligence Circuits and Systems (AICAS) · doi:10.1109/aicas59952.2024.10595903 · Cited by 8
“They are less intrusive, more cost-effective, making them a focus of current research [6] [7] [8] [9].”
BackgroundZhang, Y., Bornkamp, N., Hivert, M., Oken, E., & James, P. (2024) · JMIR Pediatrics and Parenting · doi:10.2196/59159 · Cited by 8
Novel psychotherapies for insomnia
Angelillo, M., Lancee, J., & Hertenstein, E. (2025) · Journal of Sleep Research · doi:10.1111/jsr.14470 · Cited by 8
“The designs of WSTs range from smartwatches to more specialized devices like finger-worn sensors or wristbands (Chiang & Khosla, 2023; Haghayegh et al., 2019).”
Rosa, O. D., Menghini, L., Kerr, E., Müller‐Oehring, E. M., Nooner, K. B., Hasler, B. P., Franzen, P. L., Clark, D. B., Brown, S. A., Tapert, S. F., et al. (2025) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2025.112524 · Cited by 8
Allman-Farinelli, M. A., Chen, J., Chevance, G., Partridge, S. R., Gemming, L., Patrick, K., & Godino, J. (2020) · Obesity Reviews · doi:10.1111/obr.13006 · Cited by 8
Durrani, S., Cao, S., Bo, N., Pai, J. K., Baker, J., Rawlings, L., Qureshi, Z. P., Sigua, N. L., Manchanda, S., & Khan, B. A. (2022) · Advances in Therapy · doi:10.1007/s12325-021-02013-0 · Cited by 8
“Fitbits were chosen because a systematic review showed that sleep-staging Fitbit models compared to a polysomnogram were accurate in determining total sleep time and wake after sleep onset even though Fitbit data tend to underestimate sleep-onset latency [13].”
BackgroundMethodOn the mismatch between measured and perceived sleep quality
Alecci, L., Abdalazim, N., Alchieri, L., Gashi, S., & Santini, S. (2022) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3544793.3563412 · Cited by 10
“For two participants the dataset also contains sleep start, sleep end and sleep quality measurements computed by a MiBand2 wristband, which is considered an objective tool to assess sleep [11].”
MethodZhu, Y., Stephenson, C., Moghimi, E., Jagayat, J., Nikjoo, N., Kumar, A., Shirazi, A., Patel, C., Omrani, M., & Alavi, N. (2023) · PLOS ONE · doi:10.1371/journal.pone.0285757 · Cited by 7
“Fitbit’s accuracy and strength in evaluating sleep are comparable to polysomnography, actigraphy, and self-reported measures, while providing less resource-intensive sleep monitoring than these instruments, which supports the reliability of using Fitbit to monitor sleep in this study [50–53].”
Tucker, R. M., Kim, N.-H., Gurzell, E. A., Mathi, S., Chavva, S., Senthilkumar, D., Bartunek, O., Fenton, K. C., Herndon-Fenton, S. J., Cardino, V. N., et al. (2024) · Nutrients · doi:10.3390/nu16234125 · Cited by 7
“Colorimetric optical density (O.D.) data were collected using an Agilent Biotek Synergy HT Plate Reader (Winooski, VT, USA).”
A bibliometric analysis of wearable device research in sleep science: Trends and hotspots
Lin, X. H., Guo-qing, Z., Cao, S., Wang, S., Wang, F., & Xu, M. (2025) · Medicine · doi:10.1097/md.0000000000042853 · Cited by 7
“This review, which primarily focuses on the performance of wristband-based Fitbit models in assessing sleep accuracy, [19] similarly demonstrates Shahab Haghayegh significant influence and contribution in this field.”
Stevenson, S., Suppiah, H. T., Mündel, T., & Driller, M. W. (2025) · Clocks & Sleep · doi:10.3390/clockssleep7040055 · Cited by 8
“Participants completed weekly sleep quality questionnaires, including self-reported bed and wake times, sleep latencies, sleep duration, and ratings of sleep quality, as well as any adjustments to the temperature of the ma tt ress cover twice throughout the data collection period at the end of week…”
Lee, M., Chen, C., Chen, C., & Huang, C. (2025) · Nutrients · doi:10.3390/nu18010014 · Cited by 7
The Subjectivities of Wearable Sleep-Trackers - A Discourse Analysis
Nagele, A. N., Hough, J., & Dinnen, Z. (2022) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3491101.3519677 · Cited by 9
“And the third area is medical sleep research [7, 8, 47, 64] including the study of chronobiology [18, 33], clinical sleep medicine [6, 55, 62] and medical computing [4, 32, 51].”
BackgroundYeom, J. W., Kim, H., Pack, S. P., Lee, H., Cheong, T., & Cho, C. (2025) · JMIR Mental Health · doi:10.2196/67478 · Cited by 8
“According to a recent review study, the recent-generation Fitbit models showed no significant difference in measured values of wake after sleep onset, total sleep time, and sleep efficiency, and they showed a sensitivity of 0.95-0.96 and specificity of 0.58-0.69 in detecting sleep epochs [19].”
InfluentialFitbits for Monitoring Depressive Symptoms in Older Aged Persons: Qualitative Feasibility Study
Mughal, F., Raffe, W. L., Stubbs, P. W., Kneebone, I., & Garcia, J. A. (2022) · JMIR Formative Research · doi:10.2196/33952 · Cited by 7
Is it Time to Include Wearable Sleep Trackers in the Applied Psychologists’ Toolbox?
Menghini, L., Balducci, C., & de Zambotti, M. (2024) · The Spanish Journal of Psychology · doi:10.1017/sjp.2024.8 · Cited by 7
“…between wake and sleep, and across sleep stages, such feature has been suggested to improve sleep classification accuracy (Chinoy et al., 2021; Haghayegh et al., 2019) while providing estimates of time in ‘ light ’ , ‘ deep ’ , and rapid-eye-movement (REM) sleep (e.g., Wulterkens et al.,…”
BackgroundPoor adherence to sleep and physical activity guidelines among children with epilepsy
Do, J., Webster, R. J., Longmuir, P. E., Reddy, D. N., & Pohl, D. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2020.107722 · Cited by 7
Huang, L., Zhou, J., Li, H., Wang, Y., Wu, X., & Wu, J. L. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-057117 · Cited by 7
Li, X., Mao, J. J. J., Garland, S. N., Root, J. C., Li, Q. S., Ahles, T. A., & Liou, K. T. (2024) · Supportive Care in Cancer · doi:10.1007/s00520-024-08788-6 · Cited by 9
“The Fitbit Charge 4 was used to measure sleep by using both accelerometry and heart rate data, which were analyzed using proprietary algorithms to identify sleep–wake activity [26, 27].”
de Paz-Montón, L. P., Carmona‐Torres, J. M., López-Fernández-Roldán, Á., Molina‐Madueño, R. M., Navarrete-Tejero, C., & Laredo‐Aguilera, J. A. (2026) · PeerJ · doi:10.7717/peerj.20764 · Cited by 6
Perceived usefulness of digital self-tracking among people with multiple sclerosis
Skovgaard, L., Steenberg, J. L., & Lynning, M. (2024) · Digital Health · doi:10.1177/20552076241264389 · Cited by 8
Rohr, K. E., Thomas, M. L., McCarthy, M. J., & Meruelo, A. D. (2025) · Journal of Sleep Research · doi:10.1111/jsr.70065 · Cited by 7
“However, the advent of wearable technologies, such as Fitbit devices (Haghayegh et al. 2019), has introduced objective measures of sleep that are increasingly utilised in research and clinical practise.”
Nestor, B. A., Baumer, A. M., Chimoff, J., Delecourt, B., Koike, C., Tacugue, N., Brusseau, R. R., Roy, N., Fuentes, I. A. G., Sethna, N. F., et al. (2025) · JMIR Formative Research · doi:10.2196/59074 · Cited by 6
“…of time [18], and have demonstrated high levels of accuracy and sensitivity for correctly identifying sleep episodes compared with polysomnography [19], a laboratory-based sleep methodology that leverages simultaneous recordings of multiple physiological indicators, including brain activity, eye…”
Effects of mental contrasting on sleep and associations with stress: A randomized controlled trial
Schmidt, L. I., Neubauer, A., Stoffel, M., Ditzen, B., Schirmaier, J., Farrenkopf, C., & Sieverding, M. (2023) · Journal of Health Psychology · doi:10.1177/13591053231159168 · Cited by 6
Protocol for randomized personalized trial for stress management compared to standard of care
Goodwin, A. M., Miller, D., D’Angelo, S., Perrin, A., Wiener, R., Greene, B., Romain, A.-M. N., Arader, L., Chandereng, T., Cheung, Y. K., et al. (2023) · Frontiers in Psychology · doi:10.3389/fpsyg.2023.1233884 · Cited by 7
“Participants will be permitted to use their own Fitbit device (Fitbit SenseTM, Fitbit Versa 3TM, Fitbit Charge 5TM, Fitbit Charge 4TM, Fitbit LuxeTM, Fitbit Inspire 2TM, or similar newer models that are released in the future) or will be provided one (Fitbit Charge 5TM) (Haghayegh et al., 2019).”
MethodHu, C., Wilt, G. E., Roscoe, C., Iyer, H. S., Kessler, W. H., Laden, F., Chavarro, J. E., Coull, B. A., Redline, S. S., James, P., et al. (2024) · Environmental Epidemiology · doi:10.1097/ee9.0000000000000348 · Cited by 6
Cárthaigh, S. M., Perry, J. L., & Griffin, C. P. (2022) · Behaviour and Information Technology · doi:10.1080/0144929x.2022.2136533 · Cited by 6
A longitudinal study on the effects of oxygenation on sleep in Tibetan plateau residents
Guo, C., Yan, Y., Zhu, Y., Gong, P., Liu, Y., Lin, X., & Lan, L. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.11.017 · Cited by 5
Decoding menstrual health across the lifespan: a scoping review of digital health tools in research
Johnson, S. C., O’Day, J. J., Kraus, E., Delp, S. L., & Hicks, J. L. (2026) · npj Women s Health · doi:10.1038/s44294-026-00146-7 · Cited by 8
Cucato, G. G., Snowden, C. P., McCone, E., Nesbitt, C. I., Nandhra, S., Fong, M., Kane, E., Rowland, M. K., Bhattarai, N., Court, P., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0269999 · Cited by 5
“Wrist-worn Fitbit devices are shown to have good validity for obtaining gross estimates of sleep parameters [37].”
BackgroundDreyer, R. P., Berkowitz, A., Yaggi, H. K., Schneeberg, L., Shah, N. D., Emanuel, L., Kolla, B. P., Jeffery, M. M., Deeg, M. A., Ervin, K. R., et al. (2022) · BMJ Open · doi:10.1136/bmjopen-2022-062041 · Cited by 5
The impact of forced awakening on morning blood pressure surge
Kim, Y., Howie‐Esquivel, J., Mattos, M. K., Davis, E. M., & Logan, J. G. (2024) · Heart & Lung · doi:10.1016/j.hrtlng.2024.06.011 · Cited by 5
Oberleitner, L., Baxa, D. M., Pickett, S. M., & Sawarynski, K. E. (2024) · Medical Education Online · doi:10.1080/10872981.2024.2412400 · Cited by 5
“FitBits have been shown to have comparable results to clinical sleep studies for tracking key sleep parameters in a variety of populations (ex. adults, adolescents and insomnia disorder patients) given their known limitations [8,11–14].”
BackgroundMethodResultInfluentialBraem, C. I. R., Pasman, W. J., van den Broek, T. J., Caspers, M. P. M., Jagers, F. L. P. W., Yavuz, U. Ş., Hermens, H. J., Veltink, P. H., & Wopereis, S. (2025) · BMC Digital Health · doi:10.1186/s44247-024-00145-1 · Cited by 6
“While the Fitbit Charge 4 accurately measures HR at rest [61], step count [62], and slee p– wake-patterns [63], it overestimates steps in free-living conditions [62] and has increased heart rate bias during high-intensity activities [61].”
Hong, K. J. (2025) · Nursing Open · doi:10.1002/nop2.70207 · Cited by 5
“Several studies have measured sleep efficiency, total sleep time, sleep latency and awakening index using wristband Fitbit (Haghayegh et al. 2019); therefore, actual sleep quality needs to be compared based on work intensity and demand.”
Evaluation of sound-based sleep stage prediction in shared sleeping settings
Kim, J., Kim, S., Cho, E., Kyung, H., Park, S., Hong, J., Lee, D., Oh, J., & Yoon, I. (2025) · Sleep Medicine · doi:10.1016/j.sleep.2025.106533 · Cited by 5
Greysen, S. R., Waddell, K. J., & Patel, M. S. (2022) · JMIR mhealth and uhealth · doi:10.2196/30089 · Cited by 5
“Similarly, although wearable devices have been deployed to study sleep at home, there have been very few applications of this technology to the postdischarge period specifically [14-16].”
BackgroundLiao, Y., Robertson, M. C., O’Connor, S. G., Naya, C. H., Balachandran, D. D., & Dunton, G. F. (2022) · International Journal of Behavioral Medicine · doi:10.1007/s12529-022-10123-4 · Cited by 5
“, the “gold standard” measurement for sleep) [36, 37].”
Webber, H. E., Badawi, J. C., Calvillo, D. J., Yoon, J., Weaver, M. F., Lane, S. D., & Schmitz, J. M. (2024) · Journal of Addictive Diseases · doi:10.1080/10550887.2024.2434298 · Cited by 5
Brook, J. B. H., Salo, T., Luo, A. C., Bagautdinova, J., Rush, S., Alexander‐Bloch, A. F., Baller, E. B., Calkins, M. E., Cieslak, M., Cooper, E. C., et al. (2026) · Aperture Neuro · doi:10.52294/001c.151820 · Cited by 5
Hagemann, N., Kirtley, O. J., Lafit, G., Wampers, M., Achterhof, R., Hermans, K. S. F. M., Hiekkaranta, A. P., Lecei, A., Vancampfort, D., & Myin‐Germeys, I. (2021) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/yx2eb · Cited by 5
Measuring sleep in the bedroom environment
Cook, J. D., Castelan, A. C., & Cheng, P. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822963-7.00365-0 · Cited by 5
A 2022 Survey of Commercially Available Smartphone Apps for Sleep
Doty, T. J., Stekl, E. K., Bohn, M., Klosterman, G., Simonelli, G., & Collen, J. (2023) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2023.05.008 · Cited by 4
Master, H., Annis, J. S., Ching, J., Gleichauf, K., Han, L., Coleman, P. L., Full, K. M., Zheng, N. S., Ruderfer, D. M., Hernandez, J., et al. (2025) · Journal of Medical Internet Research · doi:10.2196/71718 · Cited by 4
“…and limb movement, have demonstrated promising performance in measuring standard sleep metrics such as wake after sleep onset (WASO) and total sleep time (TST), and in classifying sleep versus wake episodes more accurately than clinical actigraphy, which relies solely on limb movement [11,12].”
Tackling inter-subject variability in smartwatch data using factorization models
Jahfari, A. N., Tax, D. M. J., van der Bilt, I., & Reinders, M. J. T. (2025) · Scientific Reports · doi:10.1038/s41598-025-12102-7 · Cited by 4
Junghans-Rutelonis, A. N., Sim, L. A., Harbeck‐Weber, C., Dresher, E. R., Timm, W., & Weiss, K. E. (2024) · Frontiers in Pain Research · doi:10.3389/fpain.2023.1325270 · Cited by 5
Pascoe, M., Wollet, A. R., Minyety, J. D. L. C., Vera, E. M., Miller, H., Celiku, O., Leeper, H. E., Fernandez, K., Reyes, J., Young, D., et al. (2024) · Neuro-Oncology Practice · doi:10.1093/nop/npae048 · Cited by 4
Bulaj, G. W., Coleman, M., Johansen, B., Kraft, S., Lam, W., Phillips, K., & Rohaj, A. (2024) · Pharmacy · doi:10.3390/pharmacy12040107 · Cited by 5
Manolitsis, I. S., Feretzakis, G., Tzelves, L. I., Αναστασίου, Α., Koumpouros, Y., Verykios, V. S., Katsimperis, S. N., Bellos, T. C., Lazarou, L. C., & VARKARAKIS, I. M. (2024) · Healthcare · doi:10.3390/healthcare12181817 · Cited by 4
“This allowed for a more granular analysis of sleep quality and its relationship with UI and other health outcomes [13].”
BackgroundIshinuki, T., Goda, E., Tatsumi, H., Kutomi, G., Ohyanagi, T., Ohnishi, H., Masuda, Y., Hui, T., & Mizuguchi, T. (2025) · SAGE Open Nursing · doi:10.1177/23779608241267079 · Cited by 4
Han, M., SANDE, F. M. V. D., Kooman, J. P., Tao, X., Preciado, P., Tisdale, L., Thwin, O., & Kotanko, P. (2025) · Kidney360 · doi:10.34067/kid.0000000761 · Cited by 4
Sleep in Aneurysmal Subarachnoid Hemorrhage Patients During Critical and Acute Care
Fowler, S. A., Walker, S., Jones, T. W., & Gell, L. (2021) · Dimensions of Critical Care Nursing · doi:10.1097/dcc.0000000000000467 · Cited by 4
Bensen-Boakes, D.-B., Murali, T., Lovato, N., Lack, L. C., & Scott, H. (2023) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2022.09.006 · Cited by 4
Use and application of wearable technology in football further education settings in the UK
TIERNEY, P. G., Clarke, N. D., & Roberts, S. J. (2024) · Sport Education and Society · doi:10.1080/13573322.2024.2404896 · Cited by 4
“Poor accuracy and unreliability in many consumer devices are still commonplace (Haghayegh et al., 2019), contributing to resistance to using wearable technology in an educational context.”
Sleep: Educational Impact and Habit Formation
Giuntella, O., Saccardo, S., & Sadoff, S. (2026) · Journal of Political Economy · doi:10.1086/740221 · Cited by 4
Cucchiaro, G., Ahumada, L. M., Gray, G., Fierstein, J. L., Yates, H., Householder, K., Frye, W. S., & Rehman, M. (2022) · JMIR Formative Research · doi:10.2196/37054 · Cited by 4
“Similarly, wearables can provide approximate information about sleep patterns, differentiating wake from sleep [8], as well as accurately measuring step count and activity duration [9].”
BackgroundHoevenaars, D., Holla, J., de Groot, S., Weijs, P. J. M., Kraaij, W., & Janssen, T. W. J. (2022) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2022.2115563 · Cited by 5
“It was shown that the Fitbit can accurately measure sleep time and sleep onset latency, allowing a valid sleep efficiency measurement in a free-living environment [34].”
BackgroundKhanie, M. S., Illum, T., Hosseinpour, N., Matsuo, K., Fan, X., & Wargocki, P. L. (2023) · E3S Web of Conferences · doi:10.1051/e3sconf/202339601106 · Cited by 4
Resident Sleep During Traditional Home Call Compared to Night Float
Chowdhary, A., Davis, J. A., Ding, L., Taravati, P., & Feng, S. (2023) · Journal of Academic Ophthalmology · doi:10.1055/s-0043-1775578 · Cited by 6
Hassinger, A. B., Kwon, M., Wang, J., Mishra, A., & Wilding, G. E. (2024) · PLoS ONE · doi:10.1371/journal.pone.0305881 · Cited by 4
Leopold, J. A., & Antman, E. M. (2021) · BMC Cardiovascular Disorders · doi:10.1186/s12872-021-02284-z · Cited by 4
ОГЛЯД СУЧАСНИХ ТЕХНОЛОГІЙ ДЛЯ ДІАГНОСТИКИ ЯКОСТІ СНУ
Іванова, Я. О., Fedorin, I. V., & Вдовиченко, О. В. (2021) · Біомедична інженерія і технологія · doi:10.20535/2617-8974.2021.6.230253 · Cited by 4
Yang, X., Hu, J.-H., Fan, L.-P., Peng, H., Shi, H.-J., Zhuang, M.-Y., Ji, F., & Peng, K. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e31668 · Cited by 3
“Previous studies compared different wearable devices with PSG, suggesting that the common wearable devices had a limited specificity but could detect the basic sleep parameters with good accuracy and sensitivity [54,55].”
Predicting long-term sleep deprivation using wearable sensors and health surveys
Trujillo, R., Zhang, E., Templeton, J. M., & Poellabauer, C. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108749 · Cited by 3
Sleep Behavior in Royal Australian Navy Shift Workers by Shift and Exposure to the SleepTank App
Devine, J. K., Cooper, N., Choynowski, J. J., & Hursh, S. R. (2024) · Military Medicine · doi:10.1093/milmed/usae253 · Cited by 4
Li, Q., Lv, W., Yuwen, W., Jia, Z., Li, X., & Guo, J. (2025) · Sleep Medicine · doi:10.1016/j.sleep.2025.106597 · Cited by 3
School start times and racial disparities in early adolescent sleep
Yip, T., Yan, J., Zhang, M., Wang, Y., Zhao, Z., Cham, H., & Alegria, M. M. (2025) · Sleep Health · doi:10.1016/j.sleh.2025.07.003 · Cited by 3
Labie, C., Runge, N., Goossens, Z., Maîresse, O., Nijs, J., Malfliet, A., Assche, D. V., de Vlam, K., Menghini, L., Verschueren, S., et al. (2025) · Sensors · doi:10.3390/s25154813 · Cited by 4
“These results align with prior performance evaluation studies [43,46,47] and support its utility for general sleep monitoring in this clinical population.”
Takano, A., Okuda, K., Sese, J., Ono, K., & Matsumoto, T. (2025) · JMIR Formative Research · doi:10.2196/73790 · Cited by 3
“As a result, total sleep time and sleep efficiency may be overestimated, while wake after sleep onset may be underestimated when compared with polysomnography [35].”
Kerkeni, M., Boukhris, O. F., Kerkeni, M., Ammar, A., Husain, W., Żmijewski, P., Jahrami, H., Chtourou, H., & Trabelsi, K. (2026) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.70193 · Cited by 3
Detecting isolated REM sleep behavior disorder at home using a lower-back wearable sensor
TZFONI, T., Tauman, R., Hausdorff, J. M., Hanein, Y., & Mirelman, A. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02412-z · Cited by 4
Circadian phenotype is associated with diurnal variation in human exercise performance
Singh, A., Ahmed, S., & Hesketh, S. J. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06352-0 · Cited by 3
“Habitual sleep–wake behaviour was assessed using wrist-worn actigraphy (Fitbit Inspire 3, Fitbit Inc., USA) over seven consecutive days prior to the first experimental trial, with monitoring maintained throughout the experimental period.”
InfluentialSleep Patterns of Premedical Undergraduate Students: Pilot Study and Protocol Evaluation
Rajput, G., Gao, A., Wu, T.-C., Tsai, C.-T., Molano, J. R. V., & Wu, D. T. Y. (2023) · JMIR Formative Research · doi:10.2196/45910 · Cited by 3
“Current validation studies suggest that while PSG remains the gold standard, Fitbit is capable of monitoring various sleep parameters that do not significantly deviate from PSG measurements [42-44]”
BackgroundButler, M. J., Chandereng, T., Ahn, H., Slotnick, S., Miller, D., Perrin, A., Rodillas, J., Friel, C. P., Goodwin, A. M., Cheung, Y. K., et al. (2025) · JMIR Formative Research · doi:10.2196/58192 · Cited by 3
“Although previous meta-analyses indicate that Fitbit activity tracking devices may overestimate sleep duration [52], the personalized N-of-1 design allows for within-participant comparisons of sleep durations between intervention periods.”
Do Patients Sleep Better at Home or in the Hospital Following Primary Total Joint Arthroplasty?
Liao, G. Y., Chansky, H. A., Manner, P. A., Brinkmann, E. J., Fernando, N. D., & Hernandez, N. M. (2025) · The Journal of Arthroplasty · doi:10.1016/j.arth.2025.05.020 · Cited by 3
Yorke, I., Boatman, C. A., Choudhury, A. R., Oakley, B. F. M., Conde, P., Sankesara, H., Ranjan, Y., Rashid, Z., Dineley, J., Downs, J. M., et al. (2025) · JMIR Research Protocols · doi:10.2196/71145 · Cited by 4
“On the other hand, Fitbit provides ready-to-use processed data with established performance against gold-standard measures [82,110,111].”
InfluentialBoukhris, O. F., Suppiah, H. T., & Driller, M. W. (2025) · Journal of Sleep Research · doi:10.1111/jsr.70120 · Cited by 3
“Prior research validated the accuracy of this man-ufacturer's actigraphy devices for measuring total sleep time and sleep onset latency in healthy adults, demonstrating comparable results to polysomnography (Haghayegh et al. 2019).”
Nipu, N., Wentzel, A., Heshmati, N., Sangi, N. K., Zhang, X., Canahuate, G. M., Fuller, C. D., & Marai, G. E. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11254617 · Cited by 3
“…terms of device reliability and affordability , relatively low-cost devices from Fitbit and Withings can reliably detect sleep-related disturbances [4], [5], or body composition fluctuations over time [6], [7], but have yet to be successfully validated in the detection of specific medical…”
Kohli, M., Moore, D. J., & Moore, R. C. (2020) · AIDS · doi:10.1097/qad.0000000000002726 · Cited by 3
“Brewer W, Swanson BT, Ortiz A. Validity of Fitbit’s active minutes as compared with a research-grade accelerometer and self-reported measures.”
MethodInfluentialCarlin, T., & Vuillerme, N. (2021) · JMIR Research Protocols · doi:10.2196/21262 · Cited by 4
“Fitbit activity trackers also have been the subject of many studies [15-25]; for example, the Charge (Fitbit Inc) costs around €150 (US $170) [35].”
Metlaine, A., Sauvet, F., Chennaoui, M., Léger, D., & Elbaz, M. (2021) · Sensors · doi:10.3390/s21237944 · Cited by 3
“Oura ring (Oura) and Fitbit Versa 2 (Fitbit now part of Google) provided the following parameters: sleep stages, total sleep time (TST), time in bed (TIB), wake after sleep onset (WASO), sleep efficiency (SE), sleep latency (SL), and resting heart rate (RHR). iSleep Watch by iSommeil provided TST, TIB, WASO, SE, and R…”
MethodInfluential[An overview on sleep research based on functional near infrared spectroscopy].
Huang, M., Jiao, X., Jiang, J., Yang, J., Chu, H., Pan, J., & Cao, Y. (2021) · PubMed · doi:10.7507/1001-5515.202102003 · Cited by 3
Tsai, C.-T., Rajput, G., Gao, A., Wu, Y., & Wu, D. T. Y. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad117 · Cited by 3
Defining and Promoting Pediatric Pulmonary Health: Understanding Sleep and Ventilatory Health
Williamson, A. A., Amin, R. S., Meltzer, L. J., Laposky, A. D., Fiks, A. G., & Tapia, I. E. (2023) · PEDIATRICS · doi:10.1542/peds.2023-062292d · Cited by 3
White, J. W., Pfledderer, C. D., Kinard, P., Beets, M. W., von Klinggraeff, L., Armstrong, B., Adams, E. L., Welk, G. J., Burkart, S. A., & Weaver, R. G. (2023) · International journal of exercise science · doi:10.70252/vnkn6618 · Cited by 4
Rahman, M. J., & Morshed, B. I. (2021) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit51626.2021.9491896 · Cited by 3
Performance of consumer wearable sleep technology
de Zambotti, M., Menghini, L., Cellini, N., Goldstein, C. A., & Baker, F. C. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822963-7.00199-7 · Cited by 3
Use of technology for real-world sleep and circadian research
Chinoy, E. D., & Markwald, R. R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822963-7.00200-0 · Cited by 3
Tung, J. Y., Gower, S., Ooteghem, K. V., Nouredanesh, M., & Gage, W. H. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818914-6.00008-9 · Cited by 2
Associations between plasma proteomic signatures and secondary sleep in older adults
Madhawa, K., Svensson, T., Nt, H., Chung, U., & Svensson, A. K. (2025) · GeroScience · doi:10.1007/s11357-025-01565-1 · Cited by 2
Metadata
- Authors
- Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J.
- Affiliations
- The University of Texas at Austin (US)
- University of Southern California (US)
- Corresponding author
- Haghayegh, Shahab
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2019-11-28
- Volume
- 21
- Issue
- 11
- Pages
- e16273
- ISSN
- 1438-8871 (ISSN-L)
- PMC
- PMC6908975
- OpenAlex
- W2980985183
- Cited by
- 446
- References
- 46
- Citations by year
- 2026: 70 · 2025: 73 · 2024: 94 · 2023: 66 · 2022: 63 · 2021: 51 · 2020: 26 · 2019: 3
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Journal of Medical Internet Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- Fitbit, sleep stage estimation, total sleep time, sleep efficiency, wake after sleep onset, sleep latency, polysomnography comparison, heart rate variability, human motion detection, device accuracy, consumer health technology
- MeSH terms
- Female, Humans, Male, Sleep, Wrist, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.