Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Open accessPublished version of a preprint
The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.
Abstract
Background: Wearable sleep monitors are of high interest to consumers and researchers because of their ability to provide estimation of sleep patterns in free-living conditions in a cost-efficient way. Objective: We conducted a systematic review of publications reporting on the performance of wristband Fitbit models in assessing sleep parameters and stages. Methods: In adherence with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement, we comprehensively searched the Cumulative Index to Nursing and Allied Health Literature (CINAHL), Cochrane, Embase, MEDLINE, PubMed, PsycINFO, and Web of Science databases using the keyword Fitbit to identify relevant publications meeting predefined inclusion and exclusion criteria. Results: The search yielded 3085 candidate articles. After eliminating duplicates and in compliance with inclusion and exclusion criteria, 22 articles qualified for systematic review, with 8 providing quantitative data for meta-analysis. In reference to polysomnography (PSG), nonsleep-staging Fitbit models tended to overestimate total sleep time (TST; range from approximately 7 to 67 mins; effect size=-0.51, P<.001; heterogenicity: I2=8.8%, P=.36) and sleep efficiency (SE; range from approximately 2% to 15%; effect size=-0.74, P<.001; heterogenicity: I2=24.0%, P=.25), and underestimate wake after sleep onset (WASO; range from approximately 6 to 44 mins; effect size=0.60, P<.001; heterogenicity: I2=0%, P=.92) and there was no significant difference in sleep onset latency (SOL; P=.37; heterogenicity: I2=0%, P=.92). In reference to PSG, nonsleep-staging Fitbit models correctly identified sleep epochs with accuracy values between 0.81 and 0.91, sensitivity values between 0.87 and 0.99, and specificity values between 0.10 and 0.52. Recent-generation Fitbit models that collectively utilize heart rate variability and body movement to assess sleep stages performed better than early-generation nonsleep-staging ones that utilize only body movement. Sleep-staging Fitbit models, in comparison to PSG, showed no significant difference in measured values of WASO (P=.25; heterogenicity: I2=0%, P=.92), TST (P=.29; heterogenicity: I2=0%, P=.98), and SE (P=.19) but they underestimated SOL (P=.03; heterogenicity: I2=0%, P=.66). Sleep-staging Fitbit models showed higher sensitivity (0.95-0.96) and specificity (0.58-0.69) values in detecting sleep epochs than nonsleep-staging models and those reported in the literature for regular wrist actigraphy. Conclusions: Sleep-staging Fitbit models showed promising performance, especially in differentiating wake from sleep. However, although these models are a convenient and economical means for consumers to obtain gross estimates of sleep parameters and time spent in sleep stages, they are of limited specificity and are not a substitute for PSG.
Overview
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Flow diagram adapted from Moher et al [14] describing the search strategy of databases to retrieve and qualify publications of relevance for review.](https://figures.cochat.ai/paper-figures/9b8cc8142bdb4533868e38b2aac9f794/accuracy-of-wristband-fitbit-models-in-assessing-sleep-systematic-review-and-figure-1.jpg)




Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The present study used wrist actigraphy Fitbits to track sleep patterns, which may underestimate total nightly sleep by 7 to 67 min (41), suggesting that students in the present samples may have been sleeping more than the estimates by wrist actigraphy suggest.”
From Nightly sleep duration predicts grade point average in the first year of college (2023) · cites this paper as [41]
In the citing paper
“The potential role of new technologies, like smartphone‐based applications (Ko et al., 2015) and consumer‐focused wearable devices (Haghayegh et al., 2019), are not yet sufficiently elaborated, and healthcare systems often do not integrate objective information provided by the patient from self‐made home recordings such as from smartphone applications.”
From Obstructive sleep apnea: transition from pathophysiology to an integrative disease model (2022) · cites this paper as Haghayegh et al., 2019
In the citing paper
“According to a recent meta-analysis, sleep-staging Fitbit devices, such as the Charge 2, showed no significant difference in measured values of WASO, TST, and SE, but they slightly underestimated SOL in comparison to the gold standard PSG [45].”
From Digital Biomarkers for Depression Screening With Wearable Devices: Cross-sectional Study With Machine Learning Modeling (2021) · cites this paper as [45]
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 2×
“As recommended, the threshold probability of 10% ( P =.10) was the basis for testing the significance of heterogenicity and also for determining statistical significance of subgroup comparisons [20,21].”
Wang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2009) · doi:10.1002/9780470743386 · Cited by 14,225 · cited 2×
“Overall effect size and 95% prediction interval for each parameter per nonsleep-staging and sleep-staging Fitbit models were calculated using a random-effects model [17,18].”
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Using Effect Size—or Why the P Value Is Not Enough
Sullivan, G. M., & Feinn, R. (2012) · Journal of Graduate Medical Education · doi:10.4300/jgme-d-12-00156.1 · Cited by 5,553 · cited 1×
“Effect size values of 0.2, 0.5, and 0.8 are considered small, medium, and large effects, respectively [19].”
InfluentialThe “All of Us” Research Program
The All of Us Research Program Investigators (2019) · New England Journal of Medicine · doi:10.1056/nejmsr1809937 · Cited by 2,440
Plea for routinely presenting prediction intervals in meta-analysis.
IntHout, J., Ioannidis, J. P. A., Rovers, M. M., & Goeman, J. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010247 · Cited by 2,264 · cited 1×
“Overall effect size and 95% prediction interval for each parameter per nonsleep-staging and sleep-staging Fitbit models were calculated using a random-effects model [17,18].”
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415 · cited 1×
“These are very promising results, since the major drawback of body activity and movement-based trackers, such as actigraphs, is overestimation of sleep time and poor sensitivity of detecting WASO (ie, poor differentiation of wake from sleep epochs during spans of quiet bedtime activity) [45,47].”
Research works printed but not linked: 2
- Wright, SP, 2017, FASEB J, 31, 1
- CoeRIt's the effect size, stupid: What effect size is and why it is importantProceedings of the Annual Conference of the British Educational Research Association2002Annual Conference of the British Educational Research AssociationSeptember 12-14, 2002University of Exeter, UK
Cited by
Pre-symptomatic detection of COVID-19 from smartwatch data
Mishra, T., Wang, M., Metwally, A. A., Bogu, G. K., Brooks, A. W., Bahmani, A., Alavi, A., Celli, A., Higgs, E., Dagan-Rosenfeld, O., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00640-6 · Cited by 463
Performance of seven consumer sleep-tracking devices compared with polysomnography
Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021) · Sleep · doi:10.1093/sleep/zsaa291 · Cited by 433
“A recent review [46] found that newer-generation Fitbit models have improved sleep-tracking performance compared with earlier models, and that Fitbit performance is overall good for sleep/ wake classification but not for sleep stages—consistent with our current findings.”
Sutton, E. L. (2021) · Annals of Internal Medicine · doi:10.7326/aitc202103160 · Cited by 284
de Zambotti, M., Goldstein, C., Cook, J., Menghini, L., Altini, M., Cheng, P., & Robillard, R. (2024) · SLEEP · doi:10.1093/sleep/zsad325 · Cited by 250
“Sleep-staging classifiers have markedly improved during this time, correctly identifying sleep stages about 50%–70% of the time [60, 159].”
The Promise of Sleep: A Multi-Sensor Approach for Accurate Sleep Stage Detection Using the Oura Ring
Altini, M., & Kinnunen, H. (2021) · Sensors · doi:10.3390/s21134302 · Cited by 193
“Given the high sensitivity and specificity for each individual stage, the proposed method might be able to better track individual changes in sleep patterns over time, with respect to currently available sensors and algorithms, which tend to detect accurately only one or two of the four stages [26,45,46].”
BackgroundMethodA Systematic Review of Sensing Technologies for Wearable Sleep Staging
Imtiaz, S. A. (2021) · Sensors · doi:10.3390/s21051562 · Cited by 162
Mehrabadi, M. A., Azimi, I., Sarhaddi, F., Axelin, A., Niela‐Vilén, H., Myllyntausta, S., Stenholm, S., Dutt, N. D., Liljeberg, P., & Rahmani, A. M. (2020) · JMIR mhealth and uhealth · doi:10.2196/20465 · Cited by 205
“In other studies, the sleep estimation of Fitbit devices [24-26], Jawbone [27-29], and physical activity monitors [30] has been investigated against actigraphy, PSG, or both in overnight tests on healthy adolescents and individuals with obstructive sleep apnea.”
Alugubelli, N. R., Abuissa, H. S., & Róka, A. (2022) · Sensors · doi:10.3390/s22228903 · Cited by 172
Obstructive sleep apnea: transition from pathophysiology to an integrative disease model
McNicholas, W. T., & Pevernagie, D. (2022) · Journal of Sleep Research · doi:10.1111/jsr.13616 · Cited by 153
Rykov, Y., Thach, T.-Q., Bojic, I., Christopoulos, G., & Car, J. (2021) · JMIR mHealth and uHealth · doi:10.2196/24872 · Cited by 151
“Although PSG is a gold standard for sleep measurement, contemporary wearables can measure sleep and identify sleep stages.”
ResultInfluentialMenghini, L., Cellini, N., Goldstone, A., Baker, F. C., & de Zambotti, M. (2020) · SLEEP · doi:10.1093/sleep/zsaa170 · Cited by 154
“For instance, Haghayegh and colleagues [9] excluded 50 of the 72 identified articles from their review on the accuracy of Fitbit devices also due to ineligible or insufficiently described method or outcomes, and they reported inconsistencies across multiple aspects such as recording setting, method of reference, and s…”
BackgroundA deep transfer learning approach for wearable sleep stage classification with photoplethysmography
Radha, M., Fonseca, P. M., Moreau, A., Ross, M., Cerny, A., Anderer, P., Long, X., & Aarts, R. M. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00510-8 · Cited by 154
COVID-19-related mobility reduction: heterogenous effects on sleep and physical activity rhythms
Ong, J. L., Lau, T., Massar, S. A. A., Chong, Z. T., Ng, B. K. L., Koek, D., Zhao, W., Yeo, B. T. T., Cheong, K., & Chee, M. W. L. (2020) · SLEEP · doi:10.1093/sleep/zsaa179 · Cited by 145
“However, validation studies on Fitbit devices conducted by several research groups (see [52] for a review of validation studies for sleep, and [53] for PA) have been encouraging, demonstrating overall high correlation values (r’s > 0.”
BackgroundDoherty, C., Baldwin, M., Keogh, A., Caulfield, B., & Argent, R. (2024) · Sports Medicine · doi:10.1007/s40279-024-02077-2 · Cited by 133
“Four systematic reviews (including one meta-analysis), two deemed to be of moderate quality [38, 42] and two of low quality, assessed the validity of wearables for measuring various aspects of sleep [37, 53].”
InfluentialLee, T., Cho, Y., Cha, K. S., Jung, J., Cho, J., Kim, H., Kim, D., Hong, J., Lee, D., Keum, M., et al. (2023) · JMIR mhealth and uhealth · doi:10.2196/50983 · Cited by 147
Lee, S. Y., & Kang, J. (2020) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2020.102849 · Cited by 142
Stalder, T., LUPIEN, S. J., Kudielka, B. M., Adam, E. K., Pruessner, J. C., Wüst, S., Dockray, S., Smyth, N., Evans, P. D., Kirschbaum, C., et al. (2022) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2022.105946 · Cited by 136
Svensson, T., Madhawa, K., Nt, H., Chung, U., & Svensson, A. K. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.01.020 · Cited by 139
Chinoy, E. D., Cuellar, J. A., Jameson, J., & Markwald, R. R. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s348795 · Cited by 130
“Over the past 5–10 years, Fitbit has consistently improved their technology (eg, added a PPG heart rate sensor in newer models) and their sleep-tracking algorithm performance.(16) To our knowledge, the current study is the first to examine sleep in the newer Inspire HR model from Fitbit, which we found performs like t…”
MethodChee, N. I. Y. N., Ghorbani, S., Golkashani, H. A., Leong, R. L. F., Ong, J. L., & Chee, M. W. L. (2021) · Nature and Science of Sleep · doi:10.2147/nss.s286070 · Cited by 120
“Other devices from this new generation of wearables that incorporate additional sensors beyond motion-only sleep detection have also shown improvements in their performance over their motion-only predecessors.(15)”
BackgroundZhang, Y., Folarin, A., Sun, S., Cummins, N., Bendayan, R., Ranjan, Y., Rashid, Z., Conde, P., Stewart, C., Laiou, P., et al. (2021) · JMIR mhealth and uhealth · doi:10.2196/24604 · Cited by 121
“However, the Fitbit devices were deemed sensitive enough to detect changes in sleep-wake states [27-29]; therefore, the provided sleep stage information could be used to determine estimates for detailed sleep parameters based on known sleep pathology.”
Association Between Slow-Wave Sleep Loss and Incident Dementia
Himali, J. J., Baril, A., Cavuoto, M. G., Yiallourou, S. R., Wiedner, C. D., Himali, D., DeCarli, C. S., Redline, S. S., Beiser, A., Seshadri, S. S., et al. (2023) · JAMA Neurology · doi:10.1001/jamaneurol.2023.3889 · Cited by 112
Połap, D., Srivastava, G., & Yu, K. (2021) · Journal of Information Security and Applications · doi:10.1016/j.jisa.2021.102748 · Cited by 106
Abeltino, A., Riente, A., Bianchetti, G., Serantoni, C., Spirito, M. D., Capezzone, S., Esposito, R., & Maulucci, G. (2024) · Nutrition Reviews · doi:10.1093/nutrit/nuae035 · Cited by 112
Forecasting Seizure Likelihood With Wearable Technology
Stirling, R. E., Grayden, D. B., D'Souza, W. J., Cook, M. J., Nurse, E. S., Freestone, D. R., Payne, D. E., Brinkmann, B. H., Attia, T. P., Viana, P. F., et al. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.704060 · Cited by 107
“Second, it is worth noting that the accuracy of heart rate and sleep stages measured from smartwatch devices has been investigated compared to electrocardiography and polysomnography, respectively (58–60).”
BackgroundAccuracy of Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP Versus Polysomnography: Systematic Review
Schyvens, A.-M., Oost, N. C. V., Aerts, J., Masci, F., Peters, B., Neven, A., Dirix, H., Wets, G., Ross, V., & Verbraecken, J. A. (2024) · JMIR mhealth and uhealth · doi:10.2196/52192 · Cited by 104
“First, the use of sleep diaries is inexpensive and straightforward for consumers, but the subjective self-ratings they require result in frequent inaccuracies and incompleteness [12].”
BackgroundStone, J. D., Rentz, L. E., Forsey, J. D., Ramadan, J. H., Markwald, R. R., Finomore, V. S., Galster, S. M., Rezai, A. R., & Hagen, J. A. (2020) · Nature and Science of Sleep · doi:10.2147/nss.s270705 · Cited by 100
Song, Y. M., Jeong, J., Reyes, A. A. D. L., V, Lim, D., Cho, C., Yeom, J. W., Lee, T., Lee, J.-B., Lee, H., & Kim, J. K. (2024) · EBioMedicine · doi:10.1016/j.ebiom.2024.105094 · Cited by 85
Ried, K., Tamanna, T., Matthews, S., & Sali, A. (2022) · Journal of Sleep Research · doi:10.1111/jsr.13793 · Cited by 84
“A systematic review and meta-analysis considered the Fitbit wrist activity tracker with the sleep feature as a reliable alternative for assessing gross sleep pattern, while also being more practical than a sleep laboratory in our study setting (Haghayegh et al., 2019).”
MethodSchyvens, A.-M., Peters, B. T., Oost, N. C. V., Aerts, J., Masci, F., Neven, A., Dirix, H., Wets, G., Ross, V., & Verbraecken, J. A. (2025) · SLEEP Advances · doi:10.1093/sleepadvances/zpaf021 · Cited by 87
“Conservative algorithms are more likely to tend toward LS rather than overestimate critical stages like DS or REM when in doubt [8–10 , 43– 45 Similar to previous research, our results showed differences for the measurements of DS and REM sleep [3, 16, 35].”
Performance assessment of new-generation Fitbit technology in deriving sleep parameters and stages
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Chronobiology International · doi:10.1080/07420528.2019.1682006 · Cited by 78
“Furthermore, Fitbit technology provides an accurate assessment of heart rate during sleep (de Zambotti et al. 2016; Haghayegh et al. 2019a), which is considered to be an important biomarker of cardiovascular disease risk (Hermida et al. 2018; Palatini and Julius 1997; Roush et al. 2014).”
BackgroundMethodResultInfluentialSelf-citationThymi, M., Lobbezoo, F., Aarab, G., Ahlberg, J., Baba, K., Carra, M. C., Gallo, L. M., Laat, A. D., Manfredini, D., Lavigne, G. J., et al. (2021) · Journal of Oral Rehabilitation · doi:10.1111/joor.13170 · Cited by 76
Ong, J. L., Golkashani, H. A., Ghorbani, S., Wong, K. F., Chee, N. I. Y. N., Willoughby, A. R., & Chee, M. W. L. (2023) · Sleep Health · doi:10.1016/j.sleh.2023.11.005 · Cited by 75
Yue, H., Chen, Z., Guo, W., Sun, L., Dai, Y., Wang, Y., Ma, W., Fan, X., Wen, W., & Lei, W. (2024) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2024.101897 · Cited by 77
Patel, V., Orchanian‐Cheff, A., & Wu, R. C. (2021) · JMIR mhealth and uhealth · doi:10.2196/17411 · Cited by 69
“A recent systematic review of Fitbit-based sleep assessments found that readings from more recently developed devices correlated well with polysomnography readings for assessing sleep episodes [41].”
BackgroundA novel machine learning unsupervised algorithm for sleep/wake identification using actigraphy
Li, X., Zhang, Y., Jiang, F., & Zhao, H. (2020) · Chronobiology International · doi:10.1080/07420528.2020.1754848 · Cited by 71
Consumer Perceptions of Wearable Technology Devices: Retrospective Review and Analysis
Chong, K. P. L., Guo, J. Z., Deng, X., & Woo, B. K. P. (2020) · JMIR mhealth and uhealth · doi:10.2196/17544 · Cited by 65
Minimum number of nights for reliable estimation of habitual sleep using a consumer sleep tracker
Lau, T., Ong, J. L., Ng, B. K. L., Chan, L. F., Koek, D., Tan, C. S., Müller‐Riemenschneider, F., Cheong, K., Massar, S. A. A., & Chee, M. W. L. (2022) · SLEEP Advances · doi:10.1093/sleepadvances/zpac026 · Cited by 69
Giddens, N. T., Juneau, P. L., Manza, P., Wiers, C. E., & Volkow, N. D. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2120009119 · Cited by 58
Validation of Fitbit Inspire 2TM Against Polysomnography in Adults Considering Adaptation for Use
Lim, S. E., Kim, H. S., Lee, S. W., Bae, K.-H., & Baek, Y. (2023) · Nature and Science of Sleep · doi:10.2147/nss.s391802 · Cited by 54
“However, the sleep onset latency is underestimated.(13) Thus, Fitbit is considered an alternative to collecting objective sleep data, which was previously only available through PSG in the laboratory.”
BackgroundResultInfluentialRentz, L. E., Ulman, H. K., & Galster, S. M. (2021) · Sensors · doi:10.3390/s21155071 · Cited by 60
“wake, wakeful periods of high relaxation and no movement have been commonly known to be incorrectly classified as sleep [68].”
BackgroundInfluentialNightly sleep duration predicts grade point average in the first year of college
Creswell, J. D., Tumminia, M. J., Price, S., Sefidgar, Y., Cohen, S., Ren, Y., Brown, J., Dey, A. K., Dutcher, J. M., Villalba, D., et al. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2209123120 · Cited by 53
Sleep and seizure risk in epilepsy: bed and wake times are more important than sleep duration
Stirling, R. E., Hidajat, C. M., Grayden, D. B., D'Souza, W. J., Naim‐Feil, J., Dell, K. L., Schneider, L. D., Nurse, E. S., Freestone, D. R., Cook, M. J., et al. (2022) · Brain · doi:10.1093/brain/awac476 · Cited by 55
“As a result, this study did not focus on sleep composition due to limitations in the wearable sleep staging algorithm.(22,23,42) Nonetheless, wearable sleep monitors provide a more objective account of sleep quality than most prior long-term sleep and epilepsy studies that used sleep diaries.”
BackgroundSun, S., Folarin, A., Zhang, Y., Cummins, N., Garcia‐Dias, R., Stewart, C., Ranjan, Y., Rashid, Z., Conde, P., Laiou, P., et al. (2023) · Journal of Medical Internet Research · doi:10.2196/45233 · Cited by 52
“First, the sleep stages provided by the Fitbit devices may differ from the gold standard using polysomnography [62]; for example, inactive status might be misclassified as sleep, which leads to overestimation of sleep duration [63].”
BackgroundThe effects of physical activity on sleep architecture and mood in naturalistic environments
Zapalac, K., Miller, M., Champagne, F. A., Schnyer, D. M., & Baird, B. (2024) · Scientific Reports · doi:10.1038/s41598-024-56332-7 · Cited by 57
“Moreover, individual studies differ in the observed discrepancies between device-measured and PSG-derived sleep metrics.”
ResultInfluentialMenghini, L., Yuksel, D., Goldstone, A., Baker, F. C., & de Zambotti, M. (2021) · Chronobiology International · doi:10.1080/07420528.2021.1903481 · Cited by 52
“(Haghayegh et al. 2019b).”
BackgroundResultInfluentialFalck, R. S., Davis, J. C., Khan, K. M., Handy, T. C., & Liu-Ambrose, T. Y. L. (2021) · American Journal of Lifestyle Medicine · doi:10.1177/15598276211031495 · Cited by 52
Lopresti, A. L., Smith, S. J., Metse, A. P., & Drummond, P. D. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.965130 · Cited by 52
Dong, X., Yang, S., Guo, Y., Lv, P., Wang, M., & Li, Y. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275287 · Cited by 49
“Interestingly, the validated actigraph AWS performed comparably to PSG in assessing TST, SE, WASO, and SOL.”
BackgroundInfluentialO’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“Predictably, newer devices that analyze more physiological signals (HR, body movement) performed better but sleep-staging devices were limited by low specificity (137).”
BackgroundMethodBurkart, S. A., Beets, M. W., Armstrong, B., Hunt, E. T., Dugger, R., von Klinggraeff, L., Jones, A., Brown, D. E., & Weaver, R. G. (2020) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8980 · Cited by 45
“5,17 9 None of these studies are directly comparable to the current study because each used different single-and multichannel devices, sampled different age groups, and used PSG in various settings.”
Saito, T., Suzuki, H., & Kishi, A. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.861808 · Cited by 48
Guarnieri, B., Maestri, M., Cucchiara, F., Gerfo, A. L., Schirru, A., Arnaldi, D., Mattioli, P., Nobili, F. M., Lombardi, G., Cerroni, G., et al. (2020) · Journal of Alzheimer s Disease · doi:10.3233/jad-200632 · Cited by 45
Radar-based sleep stage classification in children undergoing polysomnography: a pilot-study
de Goederen, R., Pu, S., Viu, M. S., Doan, D., Overeem, S., Serdijn, W. A., Joosten, K. F. M., Long, X., & Dudink, J. (2021) · Sleep Medicine · doi:10.1016/j.sleep.2021.03.022 · Cited by 46
The Importance of Data Quality Control in Using Fitbit Device Data From the Research Program
Lederer, L. E., Breton, A., Jeong, H., Master, H., Roghanizad, A. R., & Dunn, J. (2023) · JMIR mhealth and uhealth · doi:10.2196/45103 · Cited by 47
“Only Fitbit devices with heart rate tracking will include sleep staging, wake heart rate, and sleep-time heart rate [59].”
Jamieson, A., Chico, T., Jones, S. H., Chaturvedi, N., Hughes, A. D., & Orini, M. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-025-00082-6 · Cited by 51
“Fitbit devices were reported to be comparable to polysomnography in accuracy of detecting sleep phases, with 95% to 96% sensitivity and 58% to 69% speci fi city in detecting sleep epochs in a 2019 review 111 .”
Wearable Two-Dimensional Nanomaterial-Based Flexible Sensors for Blood Pressure Monitoring: A Review
Ismail, S. N. A., Nayan, N. A., Haniff, M. A. S. M., Jaafar, R., & May, Z. B. (2023) · Nanomaterials · doi:10.3390/nano13050852 · Cited by 44
“A rapid development of wearable devices has occurred since a decade ago; these devices are not limited to smartwatches [9] and fitness bands [10], and other sensing devices, such as skin patches [11–13] and electronic tattoos (e-tattoo) [14–16], are gaining increased research attention because they are more appealing…”
BackgroundDai, R., Kannampallil, T., Zhang, J., Lv, N., Ma, J., & Lu, C. (2022) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3534591 · Cited by 44
“Fitbit provides the calculation of the efficiency of sleep [25].”
BackgroundKuosmanen, E., Visuri, A., Kheirinejad, S., van Berkel, N., Koskimäki, H., Ferreira, D., & Hosio, S. J. (2022) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3546720 · Cited by 40
“The growing literature contrasting these devices against actigraphy or polysomnography illustrates that this approach tends to underestimate sleep disorders and overestimate sleep efficiency and total sleep times in typical sleepers [24], and should not be considered as a substitute for PSG [19].”
BackgroundThe past, present, and future of sleep quality assessment and monitoring
Chen, Y., Zhou, E., Wang, Y., Xu, G., Xu, G., & Chen, L. (2023) · Brain Research · doi:10.1016/j.brainres.2023.148333 · Cited by 45
NextGen Public Health Surveillance and the Internet of Things (IoT)
Sahu, K. S., Majowicz, S. E., Dubin, J. A., & Morita, P. P. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.756675 · Cited by 47
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Chronobiology International · doi:10.1080/07420528.2019.1679826 · Cited by 38
“The thus far limited number of published studies on these more advanced hardware/software systems report they perform better in assessing sleep in comparison to traditional activity/accelerometry-based systems (Haghayegh et al. 2019a, 2019b).”
BackgroundSelf-citationMilando, C. W., Black‐Ingersoll, F., Heidari, L., López-Hernández, I., de Lange, J., Negassa, A., McIntyre, A. M., Martinez, P. B., Bongiovanni, R., Levy, J. I., et al. (2022) · BMC Public Health · doi:10.1186/s12889-022-14692-7 · Cited by 38
Baron, R., & Haick, H. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00636 · Cited by 41
“47 The knowledge obtained from this data can spotlight problems like sleep apnea, enabling users to intervene promptly and improve their sleep quality.”
BackgroundLee, Y. J., Lee, J. Y., Cho, J. H., Kang, Y. J., & Choi, J. H. (2024) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.11460 · Cited by 43
Ghorbani, S., Golkashani, H. A., Chee, N. I., Teo, T. B., Dicom, A. R., Yilmaz, G., Leong, R. L., Ong, J. L., & Chee, M. W. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s359789 · Cited by 36
Manners, J., Kemps, E., Lechat, B., CATCHESIDE, P. G., Eckert, D. J., & Scott, H. (2025) · Journal of Sleep Research · doi:10.1111/jsr.14480 · Cited by 39
“WSA-derived total sleep time (TST), SE and wake after sleep onset (WASO) have been validated, compared with polysomnography (Edouard et al., 2021; Kainec et al., 2024; Lee et al., 2023; Scott et al., 2023), but extensive performance evaluation of sleep characteristics and sleep staging accuracy is lacking.”
InfluentialPires, G. N., Arnardóttir, E. S., Íslind, A. S., Leppänen, T., & McNicholas, W. T. (2023) · Journal of Sleep Research · doi:10.1111/jsr.13819 · Cited by 40
Daily links between objective smartphone use and sleep among adolescents
Burnell, K., Garrett, S. L., Nelson, B. W., Prinstein, M. J., & Telzer, E. H. (2024) · Journal of Adolescence · doi:10.1002/jad.12326 · Cited by 41
Zhang, Y., Folarin, A., Dineley, J., Conde, P., de Angel, V., Sun, S., Ranjan, Y., Rashid, Z., Stewart, C., Laiou, P., et al. (2024) · Journal of Affective Disorders · doi:10.1016/j.jad.2024.03.106 · Cited by 39
Lu, Y.-A., Lin, H., & Tsai, P. (2025) · Journal of Medical Internet Research · doi:10.2196/69657 · Cited by 35
“This lack of consistency may be attributable to the variability in the methods used to measure sleep parameters across studies, which could have affected the outcomes [58].”
Effects of window opening on the bedroom environment and resulting sleep quality
Liao, C., Delghust, M., Wargocki, P. L., & Laverge, J. (2021) · Science and Technology for the Built Environment · doi:10.1080/23744731.2021.1927177 · Cited by 34
Biondi, A., Laiou, P., Bruno, E., Viana, P. F., Schreuder, M., Hart, W. L., Nurse, E. S., Pal, D. K., & Richardson, M. P. (2020) · JMIR Research Protocols · doi:10.2196/25309 · Cited by 35
“Proprietary algorithms are implemented to identify daily steps taken, sleep, and other activities (eg, running, biking) [30].”
MethodHehr, A., Huntley, E. D., & Marusak, H. A. (2023) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2023.01.010 · Cited by 37
Kim, B., & Park, H. (2023) · European Journal of Cardiovascular Nursing · doi:10.1093/eurjcn/zvad005 · Cited by 32
Wearable Health Technology for Preoperative Risk Assessment in Elderly Patients: The WELCOME Study
Greco, M., Angelucci, A., Avidano, G., Marelli, G., Canali, S., Aceto, R., Lubian, M., Oliva, P., Piccioni, F., Aliverti, A., et al. (2023) · Diagnostics · doi:10.3390/diagnostics13040630 · Cited by 32
“Most of the studies comparing the accuracy of measure from a Fitbit wearable with a clinical-grade measure used different models, such as the Fitbit Charge, Surge, or Versa, which are able to collect more data [22,24].”
MethodSchmidt, L. I., Baetzner, A. S., Dreisbusch, M. I., Mertens, A., & Sieverding, M. (2023) · Stress and Health · doi:10.1002/smi.3330 · Cited by 36
Khan, A., Ezeugwa, J. C., & Ezeugwu, V. E. (2024) · PLoS ONE · doi:10.1371/journal.pone.0293382 · Cited by 33
Zhang, Y., Folarin, A., Sun, S., Cummins, N., Ranjan, Y., Rashid, Z., Stewart, C., Conde, P., Sankesara, H., Laiou, P., et al. (2024) · Journal of Medical Internet Research · doi:10.2196/55302 · Cited by 35
“Fitbit shows promise in identifying sleep-wake status [55,56].”
Application of deep learning to improve sleep scoring of wrist actigraphy
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., & Diller, K. R. (2020) · Sleep Medicine · doi:10.1016/j.sleep.2020.05.008 · Cited by 31
Self-citationAngelucci, A., Greco, M., Canali, S., Marelli, G., Avidano, G., Goretti, G., Cecconi, M., & Aliverti, A. (2023) · Journal of Medical Internet Research · doi:10.2196/42815 · Cited by 32
“Few studies reported that sleep duration estimated by Fitbit devices is a reliable indicator, whereas classification of sleep stages has insufficient accuracy [31,34].”
Tubbs, A. S., Kennedy, K. E. R., Alfonso‐Miller, P., Wills, C. C. A., & Grandner, M. A. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18063044 · Cited by 31
“Activity tracker data were used to calculate daily total sleep time, sleep efficiency, and percent of light, deep, and REM sleep, as these devices have demonstrated validity for estimating sleep and wake, and moderate accuracy for sleep staging, relative to polysomnography [29,30].”
MethodLiao, C., Fan, X., Bivolarova, M. P., Laverge, J., Sekhar, C., Akimoto, M., Mainka, A., Lan, L., & Wargocki, P. L. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109557 · Cited by 29
Cloud-Based Platforms for Health Monitoring: A Review
Machorro-Cano, I., Olmedo-Aguirre, J. O., Alor‐Hernández, G., Rodríguez-Mazahua, L., Sánchez-Morales, L. N., & Pérez-Castro, N. (2023) · Informatics · doi:10.3390/informatics11010002 · Cited by 28
Regalia, G., Gerboni, G., Migliorini, M., Lai, M., Pham, J., Puri, N., Pavlova, M. K., Picard, R. W., Sarkis, R. A., & Onorati, F. (2020) · Chronobiology International · doi:10.1080/07420528.2020.1835942 · Cited by 28
“Sleep/wake scoring performed by ACT-S1 on 30-sec sleep epochs showed high sensitivity (>96%), precision (>86%), F1-score (>90%), and accuracy (>83%) when compared to the published literature (de Souza et al. 2003; Haghayegh et al. 2019) also to middle-to-elderly population age-groups (Li et al.”
MethodResultInfluentialThe relationship between wearable-derived sleep features and relapse in Major Depressive Disorder
Matcham, F., Carr, E., Meyer, N., White, K. M., Oetzmann, C., Leightley, D., Lamers, F., Siddi, S., Cummins, N., Annas, P., et al. (2024) · Journal of Affective Disorders · doi:10.1016/j.jad.2024.07.136 · Cited by 31
Race, Ethnicity, and Sleep in US Children
Wang, Y., Zhao, Z., Zhang, Y., Yan, J., Zhang, M., Jelsma, E. B., Johnson, S., Cham, H., Alegria, M. M., & Yip, T. (2024) · JAMA Network Open · doi:10.1001/jamanetworkopen.2024.49861 · Cited by 27
Bani‐Issa, W., Hijazi, H. H. A., Radwan, H. M., Saqan, R., Al‐Sharman, A., Samsudin, A. B. R., Fakhry, R., Al‐Yateem, N., Rossiter, R. C., Ibrahim, A., et al. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1182758 · Cited by 27
González, D. A., Wang, D., Pollet, E., Velarde, A. G., Horn, S., Coss, P., Vaou, O., Wang, J., Li, C., Seshadri, S. S., et al. (2023) · Sleep Health · doi:10.1016/j.sleh.2023.11.012 · Cited by 27
Kuula, L., & Pesonen, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/24704 · Cited by 33
Fritz, H., Kinney, K. A., Wu, C., Schnyer, D. M., & Nagy, Z. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108835 · Cited by 27
Armstrong, B., Beets, M. W., Starrett, A., Brazendale, K., Turner‐McGrievy, G. M., Saelens, B. E., Pate, R. R., Youngstedt, S. D., Maydeu‐Olivares, A., & Weaver, R. G. (2020) · SLEEP · doi:10.1093/sleep/zsaa174 · Cited by 27
Performance of Fitbit Devices as Tools for Assessing Sleep Patterns and Associated Factors
Park, J., Ahn, E. K., Yoon, K., & Kim, J. (2024) · Journal of Sleep Medicine · doi:10.13078/jsm.240010 · Cited by 27
“5 Actigraphy, a technique used to record and analyze activities, has been used as an alternative to PSG. Actigraphy infers wakefulness and sleep based on the movements detected us-ing body-worn devices.”
BackgroundInfluentialA scoping review of sleep discrepancy methodology: What are we measuring and what does it mean?
Walton, T. F., Ree, M. J., Fueggle, S. N., & Bucks, R. S. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.11.016 · Cited by 28
Hsieh, T.-H., Liu, M.-H., Kuo, C., Wang, Y.-H., & Liang, S. (2021) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-021-00649-5 · Cited by 26
Gao, M., Roy, A., Deluty, A., Sharkey, K. M., Hoge, E. A., Liu, T., & Brewer, J. A. (2022) · Psychosomatic Medicine · doi:10.1097/psy.0000000000001083 · Cited by 24
“However, it has been shown that Fitbit devices exhibit better sensitivity than specificity, as they overestimate TST and underestimate restlessness (50,51).”
BackgroundUnfolding the role of exercise in the management of sleep disorders
Giannaki, C. D., Sakkas, G. K., Hadjigeorgiou, G. M., Manconi, M., & Bargiotas, P. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05556-6 · Cited by 25
Menghini, L., Yüksel, D., Prouty, D., Baker, F. C., King, C. D., & de Zambotti, M. (2022) · Sleep Health · doi:10.1016/j.sleh.2022.11.006 · Cited by 24
Lai, M. Y. C., Mong, M. S. A., Cheng, L. J., & Lau, Y. (2022) · Nursing and Health Sciences · doi:10.1111/nhs.13011 · Cited by 25
Botella-Serrano, M., Velasco, J. M., Sánchez, A. S., Garnica, Ó., & Hidalgo, J. I. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.998881 · Cited by 27
Metadata
- Authors
- Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J.
- Affiliations
- The University of Texas at Austin (US)
- University of Southern California (US)
- Corresponding author
- Haghayegh, Shahab
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2019-11-28
- Volume
- 21
- Issue
- 11
- Pages
- e16273
- ISSN
- 1438-8871 (ISSN-L)
- PMC
- PMC6908975
- OpenAlex
- W2980985183
- Cited by
- 446
- References
- 46
- Citations by year
- 2026: 70 · 2025: 73 · 2024: 94 · 2023: 66 · 2022: 63 · 2021: 51 · 2020: 26 · 2019: 3
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Journal of Medical Internet Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- Fitbit, sleep stage estimation, total sleep time, sleep efficiency, wake after sleep onset, sleep latency, polysomnography comparison, heart rate variability, human motion detection, device accuracy, consumer health technology
- MeSH terms
- Female, Humans, Male, Sleep, Wrist, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.