Adaptive iterative dose reduction using 3D processing for reduced-and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Objective The purpose of this study was to determine the utility of adaptive iterative dose reduction using 3D processing (AIDR 3D) for image noise reduction and assessment of radiologic findings obtained with reduced- and low-dose chest CT in patients with various pulmonary diseases. Subjects and methods Chest CT examinations at three different tube current settings and using 16- and 64-MDCT scanners were performed for 37 patients. Standard-dose (150 mAs) data were reconstructed as thin-section CT without AIDR 3D, and low-dose (25 mAs) and reduced-dose (50 mAs) data were reconstructed as thin-section CT without and with AIDR 3D. To compare image quality, image noises at all CT doses were quantitatively assessed by region of interest measurements. For comparison of radiologic finding assessments, likelihoods of occurrence of emphysema, ground-glass opacity, reticular opacity, bronchiectasis, honeycomb pattern, and nodules were evaluated on a 5-point scale. Then, image noise and agreements of radiologic findings between standard-dose CT and others were statistically evaluated. Results The image quality scores of reduced- and low-dose CT without AIDR 3D were significantly lower than those of both protocols with AIDR 3D and standard-dose CT (p 0.81). Conclusion AIDR 3D is useful for image noise reduction and assessment of radiologic findings obtained with reduced- and low-dose CT for patients with various pulmonary diseases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Based on the fact that the amount of noise on an image is inversely proportional to the square root of the radiation dose, reducing tube current and tube voltage can inevitably lead to the degradation of image quality, thereby generating a larger amount of noise on the image [30,31].”
From A Novel Singular Value Decomposition-Based Denoising Method in 4-Dimensional Computed Tomography of the Brain in Stroke Patients with Statistical Evaluation (2020) · cites this paper as [31]
In the citing paper
“Based on the fact that the amount of noise on an image is inversely proportional to the square root of the radiation dose, reducing tube current and tube voltage can inevitably lead to the degradation of image quality, thereby generating a larger amount of noise on the image [30,31].”
From A Novel Singular Value Decomposition-Based Denoising Method in 4-Dimensional Computed Tomography of the Brain in Stroke Patients with Statistical Evaluation (2020) · cites this paper as [31]
Citations
Cites
Silva, A. C., Lawder, H. J., Hara, A., Kujak, J., & Pavlicek, W. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.2953 · Cited by 560 · cited 2×
“by using other techniques, such as 3D adaptive raw data filter [11], adaptive statistical iterative reconstruction [2–5], and iterative reconstruction in image space [6, 7].”
MethodReproducibility of histomorphologic diagnoses with special reference to the kappa statistic
SVANHOLM, H., STARKLINT, H., GUNDERSEN, H. J. G., FABRICIUS, J., BARLEBO, H., & OLSEN, S. (1989) · APMIS · doi:10.1111/j.1699-0463.1989.tb00464.x · Cited by 453 · cited 2×
“00) [12].”
ResultRadiation Dose Reduction in Chest CT: A Review
Kubo, T., Lin, P.-J. P., Stiller, W., Takahashi, M., Kauczor, H.-U., Ohno, Y., & Hatabu, H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2556 · Cited by 256 · cited 2×
“construction [1].”
MethodSelf-citationGervaise, A., Osemont, B., Lecocq, S., Noel, A., Micard, E., Felblinger, J., & Blum, A. (2012) · European Radiology · doi:10.1007/s00330-011-2271-7 · Cited by 251 · cited 3×
“On the other hand, AIDR 3D processing uses a scanner model and a statistical noise model that takes both the number of photons and electrical noise into consideration to eliminate noise due to photon starvation for the projection data [8, 10].”
BackgroundMethodInfluentialSöderberg, M., & Gunnarsson, M. (2010) · Acta Radiologica · doi:10.3109/02841851003698206 · Cited by 239 · cited 1×
“Second, it has been suggested in previous publications that AEC is useful for radiation dose reduction [24–31].”
MethodPontana, F., Duhamel, A., Pagniez, J., Flohr, T., Faivre, J.-B., Hachulla, A.-L., Remy, J., & Remy-Jardin, M. (2011) · European Radiology · doi:10.1007/s00330-010-1991-4 · Cited by 230 · cited 2×
“by using other techniques, such as 3D adaptive raw data filter [11], adaptive statistical iterative reconstruction [2–5], and iterative reconstruction in image space [6, 7].”
MethodPrakash, P., Kalra, M. K., Digumarthy, S. R., Hsieh, J., Pien, H., Singh, S., Gilman, M. D., & Shepard, J.-A. O. (2010) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e3181b26c67 · Cited by 188 · cited 2×
“by using other techniques, such as 3D adaptive raw data filter [11], adaptive statistical iterative reconstruction [2–5], and iterative reconstruction in image space [6, 7].”
MethodPontana, F., Pagniez, J., Flohr, T., Faivre, J.-B., Duhamel, A., Remy, J., & Remy-Jardin, M. (2011) · European Radiology · doi:10.1007/s00330-010-1990-5 · Cited by 180 · cited 2×
“by using other techniques, such as 3D adaptive raw data filter [11], adaptive statistical iterative reconstruction [2–5], and iterative reconstruction in image space [6, 7].”
MethodDiffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction Technique
Prakash, P., Kalra, M. K., Ackman, J. B., Digumarthy, S. R., Hsieh, J., Do, S., Shepard, J.-A. O., & Gilman, M. D. (2010) · Radiology · doi:10.1148/radiol.10091487 · Cited by 162 · cited 2×
“by using other techniques, such as 3D adaptive raw data filter [11], adaptive statistical iterative reconstruction [2–5], and iterative reconstruction in image space [6, 7].”
MethodSchindera, S. T., Odedra, D., Raza, S. A., Kim, T. K., Jang, H.-J., Szucs-Farkas, Z., & Rogalla, P. (2013) · Radiology · doi:10.1148/radiol.13122349 · Cited by 159
Research works printed but not linked: 1
- Markarian B, 1993, Heitzman’s the lung: radiologic-pathologic correlation, 4
Cited by
Schindera, S. T., Odedra, D., Raza, S. A., Kim, T. K., Jang, H.-J., Szucs-Farkas, Z., & Rogalla, P. (2013) · Radiology · doi:10.1148/radiol.13122349 · Cited by 159
Kim, Y., Kim, Y. K., Lee, B. E., Lee, S. J., Ryu, Y. J., Lee, J. H., & Chang, J. H. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13629 · Cited by 129
“Thus, the former are more affected by any increase in noise [7–9, 17, 18].”
Backgroundden Harder, A. M., Willemink, M. J., de Ruiter, Q. M. B., Schilham, A. M. R., Krestin, G. P., Leiner, T., de Jong, P. A., & Budde, R. P. J. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.07.011 · Cited by 75
Zhang, W.-L., Li, M., Zhang, B., Geng, H.-Y., Liang, Y.-Q., Xu, K., & Li, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081486 · Cited by 63
“The results are in accordance with those reported by Yamada et al [24] and Ohno et al [25].”
BackgroundResultComparing five different iterative reconstruction algorithms for computed tomography in an ROC study
Jensen, K., Martinsen, A. C. T., Tingberg, A., Aaløkken, T. M., & Fosse, E. T. (2014) · European Radiology · doi:10.1007/s00330-014-3333-4 · Cited by 64
Ohno, Y., Yaguchi, A., Okazaki, T., Aoyagi, K., Yamagata, H., Sugihara, N., Koyama, H., Yoshikawa, T., & Sugimura, K. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.05.001 · Cited by 53
Self-citationRadiation dose reduction techniques for chest CT: Principles and clinical results
Ohno, Y., Koyama, H., Seki, S., Kishida, Y., & Yoshikawa, T. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.12.017 · Cited by 53
Self-citationDoo, K. W., Kang, E.-Y., Yong, H. S., Woo, O. H., Lee, K. Y., & Oh, Y.-W. (2014) · British Journal of Radiology · doi:10.1259/bjr.20130644 · Cited by 51
Pontana, F., Billard, A.-S., Duhamel, A., Schmidt, B. T., Faivre, J., HACHULLA, E., Matran, R., Rémy, J., & Rémy-Jardin, M. (2015) · Radiology · doi:10.1148/radiol.2015150849 · Cited by 42
T2 mapping of CT remodelling patterns in interstitial lung disease
Wetscherek, M. T., Eichinger, M., Kreuter, M., Kauczor, H., Herth, F. J. F., Warth, A., Pop, C. M., Heußel, C. P., & Dinkel, J. (2015) · European Radiology · doi:10.1007/s00330-015-3751-y · Cited by 42
“, have reported that CT noise reduction with iterative reconstruction is useful for various lung diseases including interstitial pneumonia even with a low dose level of 25 mAs [4] .”
BackgroundJoemai, R. M. S., Veldkamp, W. J. H., Kroft, L. J. M., Giron, I. H., & Geleijns, J. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9780 · Cited by 42
“This study was performed with AIDR 3D [16–19], which is the successor to AIDR.”
MethodLow-dose CT in COVID-19 outbreak: radiation safety, image wisely, and image gently pledge
Tofighi, S., Najafi, S., Johnston, S. K., & Gholamrezanezhad, A. (2020) · Emergency Radiology · doi:10.1007/s10140-020-01784-3 · Cited by 41
Yamashiro, T., Miyara, T., Honda, O., Kamiya, H., Murata, K., Ohno, Y., Tomiyama, N., Moriya, H., Koyama, M., Noma, S., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105735 · Cited by 38
Self-citationNishio, M., Koyama, H., Ohno, Y., Negi, N., Seki, S., Yoshikawa, T., & Sugimura, K. (2016) · American Journal of Roentgenology · doi:10.2214/ajr.15.15684 · Cited by 35
Self-citationNagata, K., Fujiwara, M., Kanazawa, H., Mogi, T., Iida, N., Mitsushima, T., Lefor, A. K., & Sugimoto, H. (2014) · European Radiology · doi:10.1007/s00330-014-3350-3 · Cited by 32
“Although the most direct method to reduce the radiation dose is to reduce the tube current, image noise is inversely proportional to the square root of the radiation dose [15].”
MethodNuclear imaging: A powerful novel approach for tuberculosis
Johnson, D. H., Via, L. E., Kim, P. S., Laddy, D. J., Lau, C., Weinstein, E. A., & Jain, S. K. (2014) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2014.08.005 · Cited by 33
“The ideal frequency of imaging within a trial is unclear, since the number of scans must be limited in order to reduce the radioactive exposure to the subject, though new scanners and protocols that deliver much lower radiation and could allow for more frequent scans[54].”
BackgroundKalmar, P. I., Quehenberger, F., Steiner, J., Lutfi, A., Bohlsen, D., Talakić, E., Hassler, E. M., & Schoellnast, H. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2014.05.017 · Cited by 30
Hassani, C., Ronco, A., Prosper, A. E., Dissanayake, S. N., Cen, S., & Lee, C. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.19245 · Cited by 29
Fully automated image quality evaluation on patient CT: Multi-vendor and multi-reconstruction study
Chun, M., Choi, J. H., Kim, S., Ahn, C., & Kim, J. H. (2022) · PLoS ONE · doi:10.1371/journal.pone.0271724 · Cited by 33
Computer‐aided detection and quantification of cavitary tuberculosis from CT scans
Xu, Z., Bağcı, U., Kübler, A., Luna, B. M., Jain, S. K., Bishai, W. R., & Mollura, D. J. (2013) · Medical Physics · doi:10.1118/1.4824979 · Cited by 28
Use of CT Imaging to Quantify Progression and Response to Treatment in Lymphangioleiomyomatosis
Gopalakrishnan, V., Yao, J., Steagall, W. K., Avila, N. A., Taveira‐DaSilva, A. M., Stylianou, M. P., Chen, M. Y., & Moss, J. (2019) · CHEST Journal · doi:10.1016/j.chest.2019.01.004 · Cited by 27
Hamabuchi, N., Ohno, Y., Kimata, H., Ito, Y., Fujii, K., Akino, N., Takenaka, D., Yoshikawa, T., Oshima, Y., Matsuyama, T., et al. (2023) · Japanese Journal of Radiology · doi:10.1007/s11604-023-01470-7 · Cited by 26
Self-citationState-of-the-Art Imaging of the Lung for Connective Tissue Disease (CTD)
Ohno, Y., Koyama, H., Yoshikawa, T., & Seki, S. (2015) · Current Rheumatology Reports · doi:10.1007/s11926-015-0546-8 · Cited by 28
Self-citationMinamishima, K., Sugisawa, K., Yamada, Y., & Jinzaki, M. (2018) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12304 · Cited by 25
“Adaptive iterative dose reduction 3D (AIDR 3D) (Toshiba Medical Systems, Otawara, Japan) is a hybrid IR technique that uses a scanner model and statistical noise model, together with projection noise estimation in the raw data domain, to reduce photon and electronic noise.(13,14) Several previous studies have indicate…”
MethodBotelho, M. P. F., Agrawal, R., Gonzalez-Guindalini, F. D., Hart, E. M., Patel, S. K., Töre, H. F., & Yaghmai, V. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.07.011 · Cited by 24
Wallihan, D. B., Podberesky, D. J., Sullivan, J., Denson, L. A., Zhang, B., Salisbury, S. R., & Towbin, A. J. (2015) · Radiology · doi:10.1148/radiol.14140468 · Cited by 23
Wu, R., Hori, M., Onishi, H., Nakamoto, A., Fukui, H., Ota, T., Nishida, T., Enchi, Y., Satoh, K., & Tomiyama, N. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.07.015 · Cited by 22
Nishio, M., Matsumoto, S., Seki, S., Koyama, H., Ohno, Y., Fujisawa, Y., Sugihara, N., Yoshikawa, T., & Sugimura, K. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2014.09.011 · Cited by 19
“Recently, the use of new types of iterative reconstruction IR) algorithms has emerged as another strategy for dose reduction, nd several studies have demonstrated that these algorithms allow or significant dose savings in CT of the chest [4–12], head [13], and bdomen [14] (for an overview, see [15,16]).”
Self-citationYang, W., Hong, J.-Y., Kim, J.-Y., Paik, S.-H., Lee, S. H., Park, J.-S., Lee, G., Kim, B. M., & Jung, Y.-J. (2020) · Sensors · doi:10.3390/s20113063 · Cited by 17
“Based on the fact that the amount of noise on an image is inversely proportional to the square root of the radiation dose, reducing tube current and tube voltage can inevitably lead to the degradation of image quality, thereby generating a larger amount of noise on the image [30,31].”
BackgroundKoyama, H., Ohno, Y., Nishio, M., Matsumoto, S., Sugihara, N., Yoshikawa, T., Seki, S., & Sugimura, K. (2014) · European Radiology · doi:10.1007/s00330-014-3207-9 · Cited by 17
“One study reported that in various pulmonary disease cases, IRwas useful for image noise reduction and for assessing radiologic findings in reduced-dose (50 mAs) and low-dose (25 mAs) CTs in comparison with standard-dose CT (150 mAs) [13].”
BackgroundMethodSelf-citationCT Imaging of Interstitial Lung Diseases
Boer, M. C. H.-D., Sprengers, R. W., Kauczor, H., & Schaefer‐Prokop, C. M. (2016) · Medical radiology · doi:10.1007/978-3-319-30355-0_7 · Cited by 16
“Similarly an excellent inter-method agreement comparing IR and FBP images for the detection of emphysema, GGO, bronchiectasis, honeycombing, and nodules has been described (Ohno et al. 2012 ).”
MethodYamashiro, T., Miyara, T., Honda, O., Tomiyama, N., Ohno, Y., Noma, S., & Murayama, S. (2015) · International Journal of COPD · doi:10.2147/copd.s74810 · Cited by 16
Self-citationOhno, Y., Aoyagi, K., Chen, Q., Sugihara, N., Iwasawa, T., Okada, F., & Aoki, T. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.01.010 · Cited by 16
Self-citationNiehues, S. M., Vahldiek, J. L., Troeltzsch, D., Hamm, B., & Shnayien, S. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.10.023 · Cited by 16
Nishimura, H., Okuda, I., Kunizawa, N., Inoue, T., Nakajima, Y., & Amano, S. (2016) · Skin Research and Technology · doi:10.1111/srt.12345 · Cited by 16
Ohno, Y., Fujisawa, Y., Fujii, K., Sugihara, N., Kishida, Y., Seki, S., & Yoshikawa, T. (2019) · Japanese Journal of Radiology · doi:10.1007/s11604-019-00823-5 · Cited by 14
Self-citationLeon, S. M., Olguin, E. A., Schaeffer, C. J., Olguín, C., Verma, N., Mohammed, T.-L. H., Grajo, J. R., & Arreola, M. M. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac0391 · Cited by 14
Kim, H., Lim, S., Park, M., Kim, K., Kang, S.-H., & Lee, Y. (2024) · Diagnostics · doi:10.3390/diagnostics14151589 · Cited by 13
“Furthermore, this study demonstrates that self-produced phantoms using 3D printers can be adaptively applied in the medical image processing field.”
BackgroundOhno, Y., Koyama, H., Fujisawa, Y., Yoshikawa, T., Inokawa, H., Sugihara, N., Seki, S., & Sugimura, K. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.11.010 · Cited by 13
Self-citationChen, C., Lin, Y.-Y., Hsu, M., Hung, C., Liao, Y., & Tsai, H. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.07.002 · Cited by 13
Role of thoracic imaging in the management of lymphangioleiomyomatosis
Crivelli, P., Ledda, R. E., Terraneo, S., Conti, M., Imeri, G., Lesma, E. A., & Marco, F. D. (2019) · Respiratory Medicine · doi:10.1016/j.rmed.2019.08.013 · Cited by 13
Nitta, N., Ikeda, M., Sonoda, A., Nagatani, Y., Ohta, S., Takahashi, M., & Murata, K. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10364 · Cited by 12
“CT Image Acquisition Using an abdominal CT phantom and a 320MDCT scanner (Aquillon ONE, Toshiba Medical Systems), we acquired images reconstructed with AIDR 3D (a modified AIDR technique developed by Toshiba Medical Systems) and with conventional FBP [10].”
MethodSeki, S., Koyama, H., Ohno, Y., Matsumoto, S., Inokawa, H., Sugihara, N., & Sugimura, K. (2015) · Acta Radiologica · doi:10.1177/0284185115603418 · Cited by 11
“In fact, in an evaluation study of various pulmonary disease cases, image quality of LDCT reconstructed with AIDR 3D was visually equal to that of standard reference (13).”
BackgroundSelf-citationJensen, K., Hagemo, G., Tingberg, A., Steinfeldt-Reisse, C., Mynarek, G. K., Rivero, R. J., Fosse, E. T., & Martinsen, A. C. T. (2020) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000001037 · Cited by 11
“Small or no differences were shown with ASiR and AIDR 3D.(22,23) In the model-based algorithms like Veo and FIRST, models for scanner properties and optics were incorporated.”
Methodden Harder, A. M., Willemink, M. J., van Hamersvelt, R. W., Vonken, E.-J. P. A., Schilham, A. M. R., Lammers, J. J., Luijk, B., Budde, R. P. J., Leiner, T., & de Jong, P. A. (2016) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000408 · Cited by 11
Chang, D., Hiss, S., Müeller, D., Hellmich, M., Borggrefe, J., Bunck, A. C., Maintz, D. C., & Hackenbroch, M. (2015) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0035-1553125 · Cited by 11
Frisch, B. K., Slebocki, K., Mammadov, K., Püsken, M., Becker, I., Maintz, D. C., & Chang, D. (2017) · Journal of International Medical Research · doi:10.1177/0300060517712165 · Cited by 11
Sakai, N., Yabuuchi, H., Kondo, M., Kojima, T., Nagatomo, K., Kawanami, S., Kamitani, T., Yonezawa, M., Nagao, M., & Honda, H. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.08.018 · Cited by 10
Miura, S., Ohno, Y., Kimura, H., & Kichikawa, K. (2014) · Acta Radiologica · doi:10.1177/0284185114524953 · Cited by 10
Self-citationMiyata, K., Nagatani, Y., Ikeda, M., Takahashi, M., Nitta, N., Matsuo, S., Ohta, S., Otani, H., Nitta‐Seko, A., Murakami, Y., et al. (2017) · British Journal of Radiology · doi:10.1259/bjr.20160555 · Cited by 9
Automated image quality assessment for chest CT scans
Reeves, A. P., Xie, Y., & Liu, S. (2017) · Medical Physics · doi:10.1002/mp.12729 · Cited by 9
“In addition, the trachea and the descending aorta lumen have been commonly used as homogeneous regions for manual evaluation of image quality from CT scans.(9,10,24) Other anatomical regions such as pectoral muscles, heart, and lung parenchyma have been considered in single slice samples for noise characterization;(9,…”
MethodMorita, S., Ogawa, Y., Yamamoto, T., Kamoshida, K., Yamazaki, H., Suzuki, K., Sakai, S., Kunihara, M., Takagi, T., & Tanabe, K. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.108853 · Cited by 9
Chest CT in the Evaluation of COPD: Recommendations of Asian Society of Thoracic Radiology
Fan, L., Seo, J. B., Ohno, Y., Lee, S., Ashizawa, K., Lee, K. Y., Yang, Q., Tanomkiat, W., Văn, C. C., Hiếu, H. T., et al. (2025) · British Journal of Radiology · doi:10.1093/bjr/tqaf111 · Cited by 8
Self-citationCT x-ray tube voltage optimisation and image reconstruction evaluation using visual grading analysis
Zheng, X., Kim, T., Davidson, R., Lee, S., Shin, C., & Yang, S. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2043201 · Cited by 9
Matsuyama, T., Nagata, H., Ozawa, Y., Ito, Y., Kimata, H., Fujii, K., Akino, N., Ueda, T., Nomura, M., Yoshikawa, T., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11376-9 · Cited by 7
“Furthermore, hybrid-type iterative reconstruction (IR), model-based IR (MBIR), and deep learning reconstruction (DLR) have been introduced and used for not only cardiac, but also thoracic imaging since 2012 [6 – 13].”
Self-citationReduced Radiation Exposure for Face Transplant Surgical Planning Computed Tomography Angiography
Schultz, K., George, E., Mullen, K. M., Steigner, M. L., Mitsouras, D., Bueno, E. M., Pomahač, B., Rybicki, F. J., & Kumamaru, K. K. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063079 · Cited by 7
“AIDR3D was introduced to reduce patient radiation exposure while maintaining image quality, and it has been used in the chest and abdomen [25,26], the coronary arteries [27–29], and for the liver perfusion imaging [30].”
MethodKim, S., Jeong, W. K., Choi, J. H., Kim, J. H., & Chun, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275531 · Cited by 7
Thompson, J. D., Chakraborty, D. P., Szczepura, K. R., Tootell, A. K., Vamvakas, I., Manning, D., & Hogg, P. (2016) · Medical Physics · doi:10.1118/1.4941017 · Cited by 6
Novel Intraoperative Navigation Using Ultra-High-Resolution CT in Robot-Assisted Partial Nephrectomy
Takahara, K., Ohno, Y., Fukaya, K., Matsukiyo, R., Nukaya, T., Takenaka, M., Zennami, K., Ichino, M., Fukami, N., Sasaki, H., et al. (2022) · Cancers · doi:10.3390/cancers14082047 · Cited by 5
Self-citationSakai, N., Yabuuchi, H., Kondo, M., Matsuo, Y., Kamitani, T., Nagao, M., Jinnouchi, M., Yonezawa, M., Kojima, T., Yano, Y., et al. (2015) · British Journal of Radiology · doi:10.1259/bjr.20150159 · Cited by 5
Bordin, A., Tibamoso-Pedraza, G., Miró, J., & Duong, L. (2023) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-023-02878-2 · Cited by 5
Area-Detector Computed Tomography for Pulmonary Functional Imaging
Ohno, Y., Ozawa, Y., Nagata, H., Bando, S., Cong, S., Takahashi, T., Oshima, Y., Hamabuchi, N., Matsuyama, T., Ueda, T., et al. (2023) · Diagnostics · doi:10.3390/diagnostics13152518 · Cited by 4
“One study reported that the image quality obtained with tube currents of 100 mA and 50 mA and an FBP algorithm was significantly lower than that for both protocols using AIDR 3D, one of the hybrid-type IR methods, for image reconstruction [27].”
MethodSelf-citationMori, S., Yashiro, H., Inoue, M., Takahara, K., Kusaka, M., & Shiroki, R. (2019) · Acta Radiologica · doi:10.1177/0284185119868909 · Cited by 4
Sekino, H., Ishii, S., Kuroiwa, D., Fujimaki, H., Sugawara, S., Suenaga, H., Hakozaki, M., Yamakuni, R., Watanabe, H., Hasegawa, O., et al. (2021) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000001171 · Cited by 3
Nagatani, Y., Takahashi, M., Ikeda, M., Nitta, N., Miyata, K., Hanaoka, J., Nakano, Y., Matsuo, S., Hamada, Y., Sonoda, A., et al. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.08.006 · Cited by 3
Schaefer‐Prokop, C. M., & Prosch, H. (2015) · European Respiratory Society eBooks · doi:10.1183/2312508x.10003015 · Cited by 2
Emerging Preclinical and Clinical Applications of Theranostics for Nononcological Disorders
Assadi, M., Jokar, N., Yordanova, A., Gholamrezanezhad, A., Amini, A., Abbasi, F., Biersack, H., Amini, A. S., Nabipour, I., & Ahmadzadehfar, H. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.03.009 · Cited by 2
Ozawa, Y., Takenaka, D., Nomura, M., Ueda, T., Kimata, H., Ito, Y., Fujii, K., Akino, N., Yoshikawa, T., Endo, M., et al. (2026) · Japanese Journal of Radiology · doi:10.1007/s11604-026-01986-8 · Cited by 1
“…lung and normal lung, pulmonary vasculatures, and bronchi were clearly depicted with CLEAR Motion were closed to or reduced-dose CT on conventional area-detector or high-definition CTs recon - structed with filter back projection or hybrid-type iterative reconstruction methods [ 28 , 34].”
InfluentialSelf-citationToraks Bilgisayarlı Tomografide Radyasyon Doz Azaltımı
Koç, G. G., Kokangül, A., & Hanalioğlu, T. (2014) · Cukurova Medical Journal (Çukurova Üniversitesi Tıp Fakültesi Dergisi) · doi:10.17826/cutf.32985 · Cited by 1
Koç, G. G., Koç, Z., Kaniyev, T., & Kokangül, A. (2019) · Health Physics · doi:10.1097/hp.0000000000001008 · Cited by 1
Au, C., Reeves, R. A., Li, Z., Gingold, E. L., Halpern, E. J., & Sundaram, B. (2022) · Medical Physics · doi:10.1002/mp.15639 · Cited by 1
Li, B., Ni, J., Chen, F., Lu, F., Zhang, L., Wu, W., & Zhang, Z. (2023) · European Journal of Radiology Open · doi:10.1016/j.ejro.2023.100537 · Cited by 1
“…because AIDR 3D can incorporate unique noise reduction processing, which include statistical and scanner models for projection data and multiple cycles of information syntheses with edge-handling, smoothing, and blending of original input images until the final output images are created [28,29].”
BackgroundOhno, Y., Takenaka, D., Kanda, T., Yoshikawa, T., Matsumoto, S., Sugihara, N., & Sugimura, K. (2012)
Self-citation下部尿路閉塞の診断,手術適応決定におけるUrodynamic 4D-CTの有用性の検討
森紳太郎, 澤田康弘, 辻知英, 崇浩, 杉., 屋代, 英., 政則, 井., 健, 髙., 守, 日., & 良一, 白. (2018) · Japanese journal of endourology · doi:10.11302/jsejje.31.244
The Impact of the COVID-19 Pandemic on the Radiation-Induced Cancer Risk in Zanjan, Iran
Chehre, H., Moradi, H., Moghimi, P., Yazdi, N., Sattari, S., & Rezaeejam, H. (2024) · Journal of Human Environment and Health Promotion · doi:10.61186/jhehp.10.2.74
“In China, the rate of normal scans was 42 % (Ohno et al., 2012).”
Nomura, M., Ohno, Y., Ito, Y., Kimata, H., Fujii, K., Akino, N., Nagata, H., Ueda, T., Yoshikawa, T., Takenaka, D., et al. (2024) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000001657
Self-citationOhno, Y., Ozawa, Y., Ueda, T., Nomura, M., Yazawa, N., Shinohara, M., Yamamoto, K., Sano, Y., Ikedo, M., Ozaki, M., et al. (2025) · European Radiology · doi:10.1007/s00330-025-12153-4
Self-citationOzawa, Y., Aoyagi, K., Takenaka, D., Oshima, Y., Hanamatsu, S., Kimata, H., Ito, Y., Fujii, K., Araoka, J., Akino, N., et al. (2026) · European Journal of Radiology Artificial Intelligence · doi:10.1016/j.ejrai.2026.100103
Self-citationNomura, M., Kimata, H., Ito, Y., Fujii, K., Akino, N., Ueda, T., Yoshikawa, T., Takenaka, D., Ozawa, Y., & Ohno, Y. (2026) · Diagnostics · doi:10.3390/diagnostics16121756
Self-citation
Metadata
- Authors
- Ohno, Y., Takenaka, D., Kanda, T., Yoshikawa, T., Matsumoto, S., Sugihara, N., & Sugimura, K.
- Affiliations
- Kobe University (JP)
- Hyogo Prefectural Cancer Center (JP)
- Toshiba (Japan) (JP)
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2012-10
- Volume
- 199
- Issue
- 4
- Pages
- W477-W485
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1964060591
- Cited by
- 79
- References
- 39
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 3 · 2023: 4 · 2022: 4 · 2021: 3 · 2020: 4 · 2019: 5 · 2018: 8 · 2017: 3 · 2016: 8 · 2015: 13 · 2014: 11 · 2013: 7 · 2012: 1
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Keywords
- adaptive iterative dose reduction, low-dose CT, chest CT, image denoising, image quality, lung disease, emphysema, ground-glass opacities, bronchiectasis, honeycomb pattern, pulmonary nodules, interobserver agreement, tube current reduction
- MeSH terms
- Adult, Aged, Aged, 80 and over, Female, Humans, Image Processing, Computer-Assisted, Lung, Lung Diseases, Male, Middle Aged, Radiation Dosage, Radiographic Image Enhancement, Tomography, X-Ray Computed, Phantoms, Imaging, Imaging, Three-Dimensional, Signal-To-Noise Ratio, Multidetector Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.