Dual-Energy CT: A Promising New Technique for Assessment of the Musculoskeletal System
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Dual-energy CT (DECT) characterizes the chemical composition of material according to its differential x-ray attenuation at two different energy levels. Applications of DECT in musculoskeletal imaging include imaging of bone marrow edema, tendons, and ligaments and the use of monoenergetic techniques to minimize metal prosthesis beam-attenuating artifacts. CONCLUSION: The most validated application of DECT is undoubtedly its noninvasive and highly specific ability for confirming the presence of monosodium urate deposits in the assessment of gout.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510 · cited 6×
“, 80 or 100 and 140 kVp); thus, it is superior to the present single-energy (singlesource) CT because of its ability to extract information and characterize the chemical composition of material according to the differential x-ray photon energy–dependent attenuation of the compounds being examined at the two different…”
BackgroundMethodInfluentialDiagnosis of Bone and Joint Disorders
Wilson, D. (2003) · Clinical Radiology · doi:10.1016/s0009-9260(02)00578-0 · Cited by 753
Soft drinks, fructose consumption, and the risk of gout in men: prospective cohort study
Choi, H. K., & Curhan, G. (2008) · BMJ · doi:10.1136/bmj.39449.819271.be · Cited by 577 · cited 1×
“Choi and Curhan [18] have reported a 1.”
BackgroundMetal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
Bamberg, F., Dierks, A., Nikolaou, K., Reiser, M. F., Becker, C. R., & Johnson, T. R. C. (2011) · European Radiology · doi:10.1007/s00330-011-2062-1 · Cited by 537 · cited 6×
“In addition, there was good interobserver agreement in both studies [12, 14].”
BackgroundMethodResultInfluentialDiagnosis of gout by ultrasound
Thiele, R. G., & Schlesinger, N. (2007) · Rheumatology · doi:10.1093/rheumatology/kem058 · Cited by 348 · cited 2×
“ever, none of these methods has been found to be sensitive or specific enough to confirm the presence of MSU crystals [16, 23–26].”
BackgroundMethodDual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341 · cited 2×
“, kidney stones) and has been validated to do so in both in vitro and in vivo studies [1, 2].”
BackgroundDual energy computed tomography in tophaceous gout
Choi, H. K., Al-Arfaj, A. M., Eftekhari, A., Munk, P. L., Shojania, K., Reid, G., & Nicolaou, S. (2009) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2008.099713 · Cited by 330 · cited 4×
“In 2009, Choi and colleagues [4] found that DECT was more efficacious than clinical assessment in identifying gout.”
BackgroundMethodSelf-citationThe value of synovial fluid assays in the diagnosis of joint disease: a literature survey
Swan, A., Amer, H., & Dieppe, P. (2002) · Annals of the Rheumatic Diseases · doi:10.1136/ard.61.6.493 · Cited by 317 · cited 1×
“In the acute setting of acute gout, Swan and colleagues [21] found that aspiration can be negative 25% of the time.”
BackgroundPache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., et al. (2010) · Radiology · doi:10.1148/radiol.10091230 · Cited by 281 · cited 5×
“[7] have recently been able to evaluate traumatic bone marrow edema using a DECT virtual non–calciumsubtraction technique.”
MethodInfluentialGlazebrook, K. N., Guimarães, L. S., Murthy, N. S., Black, D. F., Bongartz, T., J. Manek, N., Leng, S., Fletcher, J. G., & McCollough, C. H. (2011) · Radiology · doi:10.1148/radiol.11102485 · Cited by 242 · cited 3×
“Specificity for the two readers was 79% and 89%, respectively [6].”
BackgroundMethodDual energy CT in gout: a prospective validation study
Choi, H. K., Burns, L. C., Shojania, K., Koenig, N., Reid, G., Abufayyah, M., Law, G., Kydd, A. S., Ouellette, H., & Nicolaou, S. (2012) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2011-200976 · Cited by 197 · cited 5×
“The specificity in that study for MSU deposits was high; however, the sensitivity was moderate, which the authors suggested might be potentially explained by the frequent incidence of urate-lowering therapy use in their patient population [29].”
BackgroundMethodSelf-citationUltrasonographic Measurement of Tophi as an Outcome Measure for Chronic Gout
(2007) · Ultrasound Quarterly · doi:10.1097/01.ruq.0000302192.47413.16 · Cited by 178 · cited 1×
“There has also been criticism regarding the interobserver correlation for ultrasound and MRI in the assessment of tophus size [23, 27].”
BackgroundDual-Energy CT as a Potential New Diagnostic Tool in the Management of Gout in the Acute Setting
Nicolaou, S., Yong-Hing, C. J., Galea-Soler, S., Hou, D. J., Louis, L., & Munk, P. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.2428 · Cited by 175 · cited 1×
“[30] found that DECT was helpful in differentiating gout from other challenging diagnoses.”
BackgroundSelf-citationClinical Utility of Dual-Energy CT for Evaluation of Tophaceous Gout
Desai, M. A., Peterson, J. J., Garner, H. W., & Kransdorf, M. J. (2011) · RadioGraphics · doi:10.1148/rg.315115510 · Cited by 173 · cited 2×
“Utilizing this ability, DECT has been successfully shown in the literature to confirm the presence of monosodium urate (MSU) crystals in and around joints in gout arthropathy [4–6], identify bone marrow edema [7], visualize tendons and ligaments [1, 8–11], and minimize beam-hardening artifacts from bone prostheses [12…”
MethodZhou, C., Zhao, Y. E., Luo, S., Shi, H., li, L., Zheng, L., Zhang, L. J., & Lu, G. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.05.009 · Cited by 161
Gout: a clinical and radiologic review
Monu, J. U. V., & POPE, T. L. (2004) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(03)00158-1 · Cited by 153 · cited 6×
“The definitive diagnosis of gout requires microscopic analysis of fluid aspirated from the joint with the finding of negatively birefringent MSU crystals [16].”
BackgroundMethodInfluentialRecent advances in the management of gout and hyperuricemia
Wortmann, R. L. (2005) · Current Opinion in Rheumatology · doi:10.1097/01.bor.0000162060.25895.a5 · Cited by 95
Magnetic resonance imaging in the quantitative assessment of gouty tophi
Schumacher, H. R., Becker, M. A., Edwards, N. L., Palmer, W. E., MacDonald, P. A., Palo, W. A., & Joseph‐Ridge, N. (2006) · International Journal of Clinical Practice · doi:10.1111/j.1368-5031.2006.00853.x · Cited by 73 · cited 3×
“There has also been criticism regarding the interobserver correlation for ultrasound and MRI in the assessment of tophus size [23, 27].”
BackgroundMethodAn initial qualitative study of dual-energy CT in the knee ligaments
Sun, C., Fan, M., Wang, X., Wang, T., Ma, R., Wang, D., & Liu, C. (2008) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-008-0349-y · Cited by 67 · cited 5×
“Although they were able to clearly visualize the anterior and posterior cruciate ligaments, fibular collateral ligament, and patellar ligament, they were unable to satisfactorily visualize the tibial collateral ligament [11].”
BackgroundMethodInfluentialDalbeth, N., Aati, O., Gao, A., House, M. E., Liu, Q., Horne, A. M., Doyle, A., & McQueen, F. M. (2011) · JCR Journal of Clinical Rheumatology · doi:10.1097/rhu.0b013e31823e5cda · Cited by 61 · cited 2×
“DECT has been shown in recent publications to adequately confirm the presence of urate crystals in tissue with a high specificity and moderate sensitivity both in retrospective [4, 5, 7, 28] and in one randomized prospective study [29].”
Advances of dual source, dual-energy imaging in postmortem CT
Persson, A., Jackowski, C., Engström, E., & Zachrisson, H. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.05.008 · Cited by 61 · cited 3×
“However, one criticism was that, because the study was conducted on deceased patients, the datasets generated were of extremely high resolution because of the lack of limitations on radiation dose and, thus, were not representative or feasible for daily clinical application of DECT [9].”
BackgroundMethodImaging modalities and monitoring measures of gout
Pérez-Ruiz, F., & Naredo, E. (2007) · Current Opinion in Rheumatology · doi:10.1097/bor.0b013e32801450b7 · Cited by 53 · cited 2×
“ever, none of these methods has been found to be sensitive or specific enough to confirm the presence of MSU crystals [16, 23–26].”
BackgroundMethodInitial experience with visualizing hand and foot tendons by dual-energy computed tomography
Deng, K. Y., Sun, C., Liu, C., & Ma, R. (2009) · Clinical Imaging · doi:10.1016/j.clinimag.2008.12.007 · Cited by 45
Glazebrook, K. N., Brewerton, L. J., Leng, S., Carter, R. E., Rhee, P. C., Murthy, N. S., Howe, B. M., Ringler, M. D., Dahm, D. L., Stuart, M. J., et al. (2013) · Skeletal Radiology · doi:10.1007/s00256-013-1784-3 · Cited by 39
Mallinson, P. I., Stevens, C., Reisinger, C., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2013) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e318287efa0 · Cited by 37
Self-citationAdvances in the management of gout and hyperuricaemia
Hoskison, T. K., & Wortmann, R. L. (2006) · Scandinavian Journal of Rheumatology · doi:10.1080/03009740600855825 · Cited by 29
Dual energy computed tomography: simulated monoenergetic and material-selective imaging.
Hemmingsson, A., Jung, B., & Ytterbergh, C. (1986) · PubMed · Cited by 19
Dual-energy computed tomography: a valid tool in the assessment of gout?
Tashakkor, A. Y., Wang, J. T., Tso, D. K., Choi, H. K., & Nicolaou, S. (2012) · International Journal of Clinical Rheumatology · doi:10.2217/ijr.11.71 · Cited by 15
Self-citationSimoni, P., Leyder, P.-P., Albert, A., Malchair, F., Maréchal, C., Scarciolla, L., Zobel, B. B., Alvarez‐Miezentseva, V., & Gillet, P. (2013) · Skeletal Radiology · doi:10.1007/s00256-013-1759-4 · Cited by 11
Total ankle arthroplasty: optimizing computed tomography imaging protocol
Kohonen, I., Koivu, H., Vahlberg, T. J., Larjava, H. R. S., & Mattila, K. T. (2013) · Skeletal Radiology · doi:10.1007/s00256-013-1692-6 · Cited by 11
Cited by
Glyn-Jones, S., Palmer, A. J. R., Agricola, R., Price, A. J., Vincent, T. L., Weinans, H., & Carr, A. J. (2015) · The Lancet · doi:10.1016/s0140-6736(14)60802-3 · Cited by 3,151
Animal models of osteoarthritis: classification, update, and measurement of outcomes
Kuyinu, E. L., Narayanan, G., Nair, L. S., & Laurencin, C. T. (2016) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-016-0346-5 · Cited by 583
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Self-citationYeh, B. M., FitzGerald, P. F., Edic, P. M., Lambert, J. W., Colborn, R. E., Marino, M. E., Evans, P. M., Roberts, J. C., Wang, Z. J., Wong, M. J., et al. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.09.001 · Cited by 219
“Other common basis-material pairs include calcium/water, which allows visualization of gout crystals [58], and iron/water, which allows quantification of iron in the liver or other visceral organs [59].”
Background
Metadata
- Authors
- Nicolaou, S., Liang, T., Murphy, D. T., Korzan, J. R., Ouellette, H., & Munk, P.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2012-11
- Volume
- 199
- Issue
- 5_supplement
- Pages
- S78-S86
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1973651077
- Cited by
- 162
- References
- 30
- FWCI
- 7.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.