Helical CT for the preoperative localization of islet cell tumors of the pancreas: value of arterial and parenchymal phase images.
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: In two-phase helical CT, organs are scanned in both the arterial and the parenchymal phase after IV injection of contrast material. The purpose of our study was to evaluate the usefulness of two-phase helical CT for the preoperative localization of pancreatic islet cell tumors. MATERIALS AND METHODS: Ten patients with 11 surgically proven islet cell tumors were included in the study. Helical CT scans of the pancreas were obtained with 5-mm collimation and overlapping image reconstruction. Images were obtained in the arterial and parenchymal phases after contrast material injection. A test bolus was used for tailored bolus timing. Images were analyzed by two observers. If a tumor was detected, its density relative to the surrounding parenchyma was scored by consensus, using a five-point scale. RESULTS: Nine of 11 tumors could be located using two-phase helical CT (sensitivity, 82%), including one 4-mm gastrinoma. Two lesions smaller than 5 mm could not be visualized. Two tumors were easier to detect (n = 1) or could only be detected on parenchymal-phase images (n = 1). Tumor conspicuity was better on arterial-phase images in two patients. CONCLUSION: Our results show that obtaining CT scans in both the arterial and the parenchymal phase leads to improved detection of pancreatic islet cell tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036
Localization of Pancreatic Endocrine Tumors by Endoscopic Ultrasonography
Rösch, T., Lightdale, C. J., Botet, J. F., Boyce, G. A., Sivak, M. V., Yasuda, K., Heyder, N., Palazzo, L., Dancygier, H., Schusdziarra, V., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199206253262601 · Cited by 713 · cited 1×
“The reported sensitivity for tumor detection was 61-63% for transabdominal sonography [5, 6], 82% for endoscopic sonography [7], 63% for dynamic incremental CT [8], and 0-100% for MR imaging [8, 9].”
BackgroundGaliber, A. K., Reading, C. C., Charboneau, J. W., Sheedy, P. F., James, E. M., Gorman, B., Grant, C. S., van Heerden, J. A., & Telander, R. L. (1988) · Radiology · doi:10.1148/radiology.166.2.2827232 · Cited by 206
Kalender, W. A., Polacin, A., & Süss, C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00001 · Cited by 182
King, C., Reznek, R. H., Dacie, J. E., & Wass, J. A. H. (1994) · Clinical Radiology · doi:10.1016/s0009-9260(05)81790-8 · Cited by 117
Cited by
The diagnosis and medical management of advanced neuroendocrine tumors.
Kaltsas, G. A., Besser, G. M., & Grossman, A. B. (2004) · Endocrine Reviews · doi:10.1210/er.2003-0014 · Cited by 674
Endocrine tumours of the pancreas
Öberg, K., & Eriksson, B. (2005) · Best Practice & Research Clinical Gastroenterology · doi:10.1016/j.bpg.2005.06.002 · Cited by 543
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Pancreatic tumors: comparison of dual-phase helical CT and endoscopic sonography.
Legmann, P., Vignaux, O., Dousset, B., Baraza, A. J., Palazzo, L., Dumontier, I., Coste, J., Louvel, A., Roseau, G., Couturier, D., et al. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.5.9574609 · Cited by 425
Imaging of Neuroendocrine Tumors
Heller, M. T., & Shah, A. B. (2011) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2011.02.011 · Cited by 329
Metadata
- Authors
- Van Hoe, L., Gryspeerdt, S., Marchal, G., Baert, A. L., & Mertens, L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1995-12
- Volume
- 165
- Issue
- 6
- Pages
- 1437-1439
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2029127516
- Cited by
- 159
- References
- 5
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.