Breast Imaging Reporting and Data System: Inter- and Intraobserver Variability in Feature Analysis and Final Assessment
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We sought to evaluate the use of the Breast Imaging Reporting and Data System (BI-RADS) standardized mammography lexicon among and within observers and to distinguish variability in feature analysis from variability in lesion management. MATERIALS AND METHODS: Five experienced mammographers, not specifically trained in BI-RADS, used the lexicon to describe and assess 103 screening mammograms, including 30 (29%) showing cancer, and a subset of 86 mammograms with diagnostic evaluation, including 23 (27%) showing cancer. A subset of 13 screening mammograms (two with malignant findings, 11 with diagnostic evaluation) were rereviewed by each observer 2 months later. Kappa statistics were calculated as measures of agreement beyond chance. RESULTS: After diagnostic evaluation, the interobserver kappa values for describing features were as follows: breast density, 0.43; lesion type, 0.75; mass borders, 0.40; special cases, 0.56; mass density, 0.40; mass shape, 0.28; microcalcification morphology, 0.36; and microcalcification distribution, 0.47. Lesion management was highly variable, with a kappa value for final assessment of 0.37. When we grouped assessments recommending immediate additional evaluation and biopsy (BI-RADS categories 0, 4, and 5 combined) versus follow-up (categories 1, 2, and 3 combined), five observers agreed on management for only 47 (55%) of 86 lesions. Intraobserver agreement on management (additional evaluation or biopsy versus follow-up) was seen in 47 (85%) of 55 interpretations, with a kappa value of 0.35-1.0 (mean, 0.60) for final assessment. CONCLUSION: Inter- and intraobserver variability in mammographic interpretation is substantial for both feature analysis and management. Continued development of methods to improve standardization in mammographic interpretation is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859
Variability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Periodic mammographic follow-up of probably benign lesions: results in 3,184 consecutive cases.
Sickles, E. A. (1991) · Radiology · doi:10.1148/radiology.179.2.2014293 · Cited by 555
A One-Way Components of Variance Model for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529465 · Cited by 478
Liberman, L., Abramson, A. F., Squires, F. B., Glassman, J. R., Morris, E. A., & Dershaw, D. D. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.1.9648759 · Cited by 460
Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
SVANHOLM, H., STARKLINT, H., GUNDERSEN, H. J. G., FABRICIUS, J., BARLEBO, H., & OLSEN, S. (1989) · APMIS · doi:10.1111/j.1699-0463.1989.tb00464.x · Cited by 453
BI-RADS Categorization As a Predictor of Malignancy
Orel, S. G., Kay, N., Reynolds, C., & Sullivan, D. C. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn31845 · Cited by 394
Beam, C. A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440020119016 · Cited by 337
Kerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., & Sickles, E. A. (1998) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/90.23.1801 · Cited by 298
Breast cancer: prediction with artificial neural network based on BI-RADS standardized lexicon.
Baker, J. A., Kornguth, P. J., Lo, J. Y., Williford, M. E., & Floyd, C. E. (1995) · Radiology · doi:10.1148/radiology.196.3.7644649 · Cited by 215
Harvey, J. A., Fajardo, L. L., & Innis, C. A. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.161.6.8249720 · Cited by 195
Baker, J. A., Kornguth, P. J., & Floyd, C. E. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.4.8610547 · Cited by 178
D’Orsi, C. J., & Kopans, D. B. (1993) · Seminars in Roentgenology · doi:10.1016/s0037-198x(05)80080-x · Cited by 99
Reading and decision aids for improved accuracy and standardization of mammographic diagnosis.
D’Orsi, C. J., Getty, D. J., Swets, J. A., Pickett, R. M., Seltzer, S. E., & McNeil, B. J. (1992) · Radiology · doi:10.1148/radiology.184.3.1509042 · Cited by 57
Yerushalmy, J., Garland, L. H., HARKNESS, J. T., Hinshaw, H. C., MILLER, E. R., SHIPMEN, S. J., & Zwerling, H. B. (1951) · PubMed · doi:10.1164/art.1951.64.3.225 · Cited by 48
The Accuracy of Mammographic Interpretation
Kopans, D. B. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312213 · Cited by 46
Variability in the interpretation of mammograms.
Cj, D., & Swets, J. A. (1995) · PubMed · Cited by 14
Variability in the Interpretation of Mammograms
Silen, W. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504273321713 · Cited by 9
Cited by
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Gharib, H., Papini, E., Garber, J. R., Duick, D. S., Harrell, R. M., Hegedus, L., Paschke, R., Valcavi, R., & Vitti, P. (2016) · Endocrine Practice · doi:10.4158/ep161208.gl · Cited by 1,272
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Dickinson, L., Ahmed, H. U., Allen, C., Barentsz, J. O., Carey, B., Futterer, J. J., Heijmink, S. W., Hoskin, P. J., Kirkham, A., Padhani, A. R., et al. (2011) · European Urology · doi:10.1016/j.eururo.2010.12.009 · Cited by 737
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Metadata
- Authors
- Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2000-06
- Volume
- 174
- Issue
- 6
- Pages
- 1769-1777
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1860760959
- Cited by
- 1,273
- References
- 21
- FWCI
- 26.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.