Breast Imaging Reporting and Data System: Inter- and Intraobserver Variability in Feature Analysis and Final Assessment
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We sought to evaluate the use of the Breast Imaging Reporting and Data System (BI-RADS) standardized mammography lexicon among and within observers and to distinguish variability in feature analysis from variability in lesion management. MATERIALS AND METHODS: Five experienced mammographers, not specifically trained in BI-RADS, used the lexicon to describe and assess 103 screening mammograms, including 30 (29%) showing cancer, and a subset of 86 mammograms with diagnostic evaluation, including 23 (27%) showing cancer. A subset of 13 screening mammograms (two with malignant findings, 11 with diagnostic evaluation) were rereviewed by each observer 2 months later. Kappa statistics were calculated as measures of agreement beyond chance. RESULTS: After diagnostic evaluation, the interobserver kappa values for describing features were as follows: breast density, 0.43; lesion type, 0.75; mass borders, 0.40; special cases, 0.56; mass density, 0.40; mass shape, 0.28; microcalcification morphology, 0.36; and microcalcification distribution, 0.47. Lesion management was highly variable, with a kappa value for final assessment of 0.37. When we grouped assessments recommending immediate additional evaluation and biopsy (BI-RADS categories 0, 4, and 5 combined) versus follow-up (categories 1, 2, and 3 combined), five observers agreed on management for only 47 (55%) of 86 lesions. Intraobserver agreement on management (additional evaluation or biopsy versus follow-up) was seen in 47 (85%) of 55 interpretations, with a kappa value of 0.35-1.0 (mean, 0.60) for final assessment. CONCLUSION: Inter- and intraobserver variability in mammographic interpretation is substantial for both feature analysis and management. Continued development of methods to improve standardization in mammographic interpretation is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859
Variability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Periodic mammographic follow-up of probably benign lesions: results in 3,184 consecutive cases.
Sickles, E. A. (1991) · Radiology · doi:10.1148/radiology.179.2.2014293 · Cited by 555
A One-Way Components of Variance Model for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529465 · Cited by 478
Liberman, L., Abramson, A. F., Squires, F. B., Glassman, J. R., Morris, E. A., & Dershaw, D. D. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.1.9648759 · Cited by 460
Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
SVANHOLM, H., STARKLINT, H., GUNDERSEN, H. J. G., FABRICIUS, J., BARLEBO, H., & OLSEN, S. (1989) · APMIS · doi:10.1111/j.1699-0463.1989.tb00464.x · Cited by 453
BI-RADS Categorization As a Predictor of Malignancy
Orel, S. G., Kay, N., Reynolds, C., & Sullivan, D. C. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn31845 · Cited by 394
Cited by
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Gharib, H., Papini, E., Garber, J. R., Duick, D. S., Harrell, R. M., Hegedus, L., Paschke, R., Valcavi, R., & Vitti, P. (2016) · Endocrine Practice · doi:10.4158/ep161208.gl · Cited by 1,272
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Dickinson, L., Ahmed, H. U., Allen, C., Barentsz, J. O., Carey, B., Futterer, J. J., Heijmink, S. W., Hoskin, P. J., Kirkham, A., Padhani, A. R., et al. (2011) · European Urology · doi:10.1016/j.eururo.2010.12.009 · Cited by 737
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Mammographic density and breast cancer risk: current understanding and future prospects
Boyd, N. F., Martin, L. J., Yaffe, M. J., & Minkin, S. (2011) · Breast Cancer Research · doi:10.1186/bcr2942 · Cited by 609
Stefanick, M. L., Anderson, G. L., Margolis, K. L., Hendrix, S. L., Rodabough, R. J., Paskett, E. D., Lane, D. S., Hubbell, F. A., Assaf, A. R., Sarto, G. E., et al. (2006) · JAMA · doi:10.1001/jama.295.14.1647 · Cited by 571
BI-RADS Lexicon for US and Mammography: Interobserver Variability and Positive Predictive Value
Lazarus, E., Mainiero, M. B., Schepps, B., Koelliker, S. L., & Livingston, L. S. (2006) · Radiology · doi:10.1148/radiol.2392042127 · Cited by 511
Kelly, K. M., Dean, J., Comulada, W. S., & Lee, S.-J. (2010) · European Radiology · doi:10.1007/s00330-009-1588-y · Cited by 497
Quantitative Assessment of Mammographic Breast Density: Relationship with Breast Cancer Risk
Harvey, J. A., & Bovbjerg, V. E. (2004) · Radiology · doi:10.1148/radiol.2301020870 · Cited by 491
Prospective Breast Cancer Risk Prediction Model for Women Undergoing Screening Mammography
Barlow, W. E., White, E., Ballard-Barbash, R., Vacek, P. M., Titus-Ernstoff, L., Carney, P. A., Tice, J. A., Buist, D. S. M., Geller, B. M., Rosenberg, R., et al. (2006) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djj331 · Cited by 463
Improving Communication of Diagnostic Radiology Findings through Structured Reporting
Schwartz, L. H., Panicek, D. M., Berk, A. R., Li, Y., & Hricak, H. (2011) · Radiology · doi:10.1148/radiol.11101913 · Cited by 435
Postmenopausal Hormone Therapy and Change in Mammographic Density
Greendale, G. A., Reboussin, B. A., Slone, S., Wasilauskas, C., Pike, M. C., & Ursin, G. (2003) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/95.1.30 · Cited by 419
Mammographic density, breast cancer risk and risk prediction
Vachon, C. M., van Gils, C. H., Sellers, T. A., Ghosh, K., Pruthi, S., Brandt, K. R., & Pankratz, V. S. (2007) · Breast Cancer Research · doi:10.1186/bcr1829 · Cited by 346
Sardanelli, F., Podo, F., D'Agnolo, G., Verdecchia, A., Santaquilani, M., Musumeci, R., Trecate, G., Manoukian, S., Morassut, S., de Giacomi, C., et al. (2007) · Radiology · doi:10.1148/radiol.2423051965 · Cited by 339
Implementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study
Rose, S. L., Tidwell, A. L., Bujnoch, L. J., Kushwaha, A. C., Nordmann, A. S., & Sexton, R. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9672 · Cited by 329
Nothacker, M., Duda, V., Hahn, M., Warm, M., Degenhardt, F., Madjar, H., Weinbrenner, S., & Albert, U.-S. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-335 · Cited by 314
Mammographic Breast Density Assessment Using Deep Learning: Clinical Implementation
Lehman, C. D., Yala, A., Schuster, T., Dontchos, B., Bahl, M., Swanson, K., & Barzilay, R. (2019) · Radiology · doi:10.1148/radiol.2018180694 · Cited by 294
Early Detection and Screening for Breast Cancer
Coleman, C. (2017) · Seminars in Oncology Nursing · doi:10.1016/j.soncn.2017.02.009 · Cited by 281
A deep learning method for classifying mammographic breast density categories
Mohamed, A. A., Berg, W. A., Peng, H., Luo, Y., Jankowitz, R. C., & Wu, S. (2018) · Medical Physics · doi:10.1002/mp.12683 · Cited by 266
Self-citationLewin, J. M., D'Orsi, C. J., Hendrick, R. E., Moss, L. J., Isaacs, P. K., Karellas, A., & Cutter, G. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.3.1790671 · Cited by 257
Evans, A., Whelehan, P., Thomson, K., Brauer, K., Jordan, L., Purdie, C., McLean, D., Baker, L., Vinnicombe, S., & Thompson, A. (2012) · British Journal of Cancer · doi:10.1038/bjc.2012.253 · Cited by 245
Mammographic density. Measurement of mammographic density
Yaffe, M. J. (2008) · Breast Cancer Research · doi:10.1186/bcr2102 · Cited by 235
Yaghjyan, L., Colditz, G. A., Collins, L. C., Schnitt, S. J., Rosner, B., Vachon, C., & Tamimi, R. M. (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr225 · Cited by 232
Londero, V., Bazzocchi, M., Del Frate, C., Puglisi, F., Di Loreto, C., Francescutti, G., & Zuiani, C. (2004) · European Radiology · doi:10.1007/s00330-004-2246-z · Cited by 232
Ciatto, S., Houssami, N., Apruzzese, A., Bassetti, E., Brancato, B., Carozzi, F., Catarzi, S., Lamberini, M. P., Marcelli, G., Pellizzoni, R., et al. (2005) · The Breast · doi:10.1016/j.breast.2004.12.004 · Cited by 231
Interobserver and Intraobserver Variations in Ultrasound Assessment of Thyroid Nodules
Choi, S. H., Kim, E.-K., Kwak, J. Y., Kim, M. J., & Son, E. J. (2010) · Thyroid · doi:10.1089/thy.2008.0354 · Cited by 225
Youk, J. H., Son, E. J., Chung, J., Kim, J.-A., & Kim, E.-K. (2012) · European Radiology · doi:10.1007/s00330-012-2425-2 · Cited by 221
First experiences in screening women at high risk for breast cancer with MR imaging
Tilanus-Linthorst, M. M. A., Obdeijn, I. M. M., Bartels, K. C. M., de Koning, H. J., & Oudkerk, M. (2000) · Breast Cancer Research and Treatment · doi:10.1023/a:1006480106487 · Cited by 216
Berg, W. A., D’Orsi, C. J., Jackson, V. P., Bassett, L. W., Beam, C. A., Lewis, R. S., & Crewson, P. E. (2002) · Radiology · doi:10.1148/radiol.2243011626 · Cited by 208
Self-citationSprague, B. L., Conant, E. F., Onega, T., Garcia, M. P., Beaber, E. F., Herschorn, S. D., Lehman, C. D., Tosteson, A. N. A., Lacson, R., Schnall, M. D., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-2934 · Cited by 202
“58 for interradiologist agreement (13, 14).”
Tilanus‐Linthorst, M., Verhoog, L., Obdeijn, I., Bartels, K., Menke‐Pluymers, M., Eggermont, A., Klijn, J., Meijers‐Heijboer, H., van der Kwast, T., & Brekelmans, C. (2002) · International Journal of Cancer · doi:10.1002/ijc.10666 · Cited by 195
Triple-negative breast cancer: correlation between imaging and pathological findings
Ko, E. S., Lee, B. H., Kim, H.-A., Noh, W.-C., Kim, M. S., & Lee, S.-A. (2010) · European Radiology · doi:10.1007/s00330-009-1656-3 · Cited by 194
Diffusion MRI of the breast: Current status and future directions
Iima, M., Honda, M., Sigmund, E. E., Ohno Kishimoto, A., Kataoka, M., & Togashi, K. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26908 · Cited by 187
Rijnsburger, A. J., Obdeijn, I.-M., Kaas, R., Tilanus-Linthorst, M. M. A., Boetes, C., Loo, C. E., Wasser, M. N. J. M., Bergers, E., Kok, T., Muller, S. H., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.27.2294 · Cited by 183
Brandt, K. R., Scott, C. G., Ma, L., Mahmoudzadeh, A. P., Jensen, M. R., Whaley, D. H., Wu, F. F., Malkov, S., Hruska, C. B., Norman, A. D., et al. (2016) · Radiology · doi:10.1148/radiol.2015151261 · Cited by 183
“This rating has shown moderate interobserver reliability (24).”
BackgroundObserver variability of Breast Imaging Reporting and Data System (BI-RADS) for breast ultrasound
Lee, H.-J., Kim, E.-K., Kim, M. J., Youk, J. H., Lee, J. Y., Kang, D. R., & Oh, K. K. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.04.008 · Cited by 181
Tailored Supplemental Screening for Breast Cancer: What Now and What Next?
Berg, W. A. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1706 · Cited by 181
“Although there are some situations in which estimated breast density from twoview mammography may be inaccurate [60], the visual assessment of “dense” can be made quite consistently at the extremes [61] where the risk is highest.”
BackgroundSelf-citationFujioka, T., Kubota, K., Mori, M., Kikuchi, Y., Katsuta, L., Kasahara, M., Oda, G., Ishiba, T., Nakagawa, T., & Tateishi, U. (2019) · Japanese Journal of Radiology · doi:10.1007/s11604-019-00831-5 · Cited by 177
Accuracy of Diagnostic Procedures: Has It Improved Over the Past Five Decades?
Berlin, L. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1270 · Cited by 165
Nelson, H. D., Tyne, K., Naik, A. M., Bougatsos, C., Chan, B. K. S., Nygren, P., & Humphrey, L. L. (2009) · PubMed Central · doi:10.1059/0003-4819-151-10-200911170-00009 · Cited by 164
Receiver Operating Characteristic Analysis
Eng, J. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.04.005 · Cited by 164
Redondo, A., Comas, M., Macià, F., Ferrer, F., Murta-Nascimento, C., Maristany, M. T., Molins, E., Sala, M., & Castells, X. (2012) · The British Journal of Radiology · doi:10.1259/bjr/21256379 · Cited by 162
“Berg et al [9] found moderate agreement (K:=0.”
BackgroundMethodInfluentialVolumetric Breast Density Estimation from Full-Field Digital Mammograms: A Validation Study
Gubern-Mérida, A., Kallenberg, M., Platel, B., Mann, R. M., Martí, R., & Karssemeijer, N. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085952 · Cited by 160
Jones, B. A., Dailey, A., Calvocoressi, L., Reams, K., Kasl, S. V., Lee, C., & Hsu, H. (2005) · Cancer Causes & Control · doi:10.1007/s10552-005-2905-7 · Cited by 112
Lyell, D., Coiera, E., Chen, J., Shah, P., & Magrabi, F. (2021) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2020-100301 · Cited by 95
Improving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Rezazade Mehrizi, M. H., Mol, F., Peter, M., Ranschaert, E., Dos Santos, D. P., Shahidi, R., Fatehi, M., & Dratsch, T. (2023) · Scientific Reports · doi:10.1038/s41598-023-36435-3 · Cited by 54
To Err Is Human, to Correct Divine: The Emergence of Technology-Based Communication Systems
Brenner, R. J. (2006) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2006.01.021 · Cited by 12
Metadata
- Authors
- Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2000-06
- Volume
- 174
- Issue
- 6
- Pages
- 1769-1777
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1860760959
- Cited by
- 1,273
- References
- 21
- FWCI
- 26.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.