Low-Dose High-Resolution CT of the Chest in Children and Young Adults: Dose, Cooperation, Artifact Incidence, and Image Quality

Lucaya, Javier, Piqueras, Joaquim, García-Peña, Pilar, Enríquez, Goya, García-Macías, Maribel, Sotil, Jesús · 2000 · American Journal of Roentgenology
Cited by 165

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The radiation dose, artifact incidence, and image quality of high-resolution chest CT examinations performed with standard and low doses and patient cooperation were investigated in children and young adults. SUBJECTS AND METHODS: Three successive controlled studies were conducted in different groups of children and young adults, totaling 203 patients. Dosimetry of high-resolution CT was performed at 180, 50, and 34 mAs in three groups of 25 patients. Streak artifact incidence using alternating 50- and 34-mAs slices was assessed and correlated with patient compliance with breath-holding commands in 44 children. Image quality was evaluated in scans obtained with 34 versus 180 mAs in cooperative patients (n = 42) and in scans obtained with 50 versus 180 mAs in noncooperative patients (n = 42). Artifacts and image quality were assessed by controlled repeated interpretations. RESULTS: Radiation dose was 5.4+/-1.6 mSv for 180 mAs, 1.5+/-0.5 mSv for 50 mAs, and 1.1+/-0.3 mSv for 34 mAs. Cooperation was obtained in 66% of the patients. Artifacts were more frequently seen in scans of noncooperative patients (30%) and in 34-mAs scans (47%); the highest incidence was found using 34 mAs in noncooperative patients (60%, p = 0.02). No differences in image quality scores were seen in scans obtained with 50 mAs versus those obtained with 180 mAs in noncooperative patients (p<0.05), and small differences were found in scans obtained with 34 mAs versus those obtained with 180 mAs in cooperative patients for fissures (p = 0.005) and peripheral structures (p = 0.02). CONCLUSION: Low-dose high-resolution CT provided a significant reduction in radiation dose (72% for 50 mAs and 80% for 34 mAs) and good-quality images of the lung when performed with 50 mAs in noncooperative and 34 mAs in cooperative pediatric and young adult patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.175.4.1750985

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 165

Metadata

Authors
Lucaya, J., Piqueras, J., García-Peña, P., Enríquez, G., García-Macías, M., & Sotil, J.
Venue
American Journal of Roentgenology
Published
2000-10
Volume
175
Issue
4
Pages
985-992
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2159972375
Cited by
165
References
15
FWCI
6.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.