Low-Dose High-Resolution CT of the Chest in Children and Young Adults: Dose, Cooperation, Artifact Incidence, and Image Quality
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The radiation dose, artifact incidence, and image quality of high-resolution chest CT examinations performed with standard and low doses and patient cooperation were investigated in children and young adults. SUBJECTS AND METHODS: Three successive controlled studies were conducted in different groups of children and young adults, totaling 203 patients. Dosimetry of high-resolution CT was performed at 180, 50, and 34 mAs in three groups of 25 patients. Streak artifact incidence using alternating 50- and 34-mAs slices was assessed and correlated with patient compliance with breath-holding commands in 44 children. Image quality was evaluated in scans obtained with 34 versus 180 mAs in cooperative patients (n = 42) and in scans obtained with 50 versus 180 mAs in noncooperative patients (n = 42). Artifacts and image quality were assessed by controlled repeated interpretations. RESULTS: Radiation dose was 5.4+/-1.6 mSv for 180 mAs, 1.5+/-0.5 mSv for 50 mAs, and 1.1+/-0.3 mSv for 34 mAs. Cooperation was obtained in 66% of the patients. Artifacts were more frequently seen in scans of noncooperative patients (30%) and in 34-mAs scans (47%); the highest incidence was found using 34 mAs in noncooperative patients (60%, p = 0.02). No differences in image quality scores were seen in scans obtained with 50 mAs versus those obtained with 180 mAs in noncooperative patients (p<0.05), and small differences were found in scans obtained with 34 mAs versus those obtained with 180 mAs in cooperative patients for fissures (p = 0.005) and peripheral structures (p = 0.02). CONCLUSION: Low-dose high-resolution CT provided a significant reduction in radiation dose (72% for 50 mAs and 80% for 34 mAs) and good-quality images of the lung when performed with 50 mAs in noncooperative and 34 mAs in cooperative pediatric and young adult patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Statistical power analysis for the behavioral sciences
(1990) · Computers, Environment and Urban Systems · doi:10.1016/0198-9715(90)90050-4 · Cited by 65,269
Statistical Power Analysis for the Behavioral Sciences (2nd ed.).
Lachenbruch, P. A., & Cohen, J. (1989) · Journal of the American Statistical Association · doi:10.2307/2290095 · Cited by 37,395
A General Methodology for the Analysis of Experiments with Repeated Measurement of Categorical Data
Koch, G. G., Landis, J. R., Freeman, J. L., Freeman, D. H., & Lehnen, R. G. (1977) · Biometrics · doi:10.2307/2529309 · Cited by 609
High-Resolution CT of the Lung
Webb, W. R., Muller, N. L., Naidich, D. P., & Meziane, M. A. (1997) · Journal of Bronchology · doi:10.1097/00128594-199704000-00036 · Cited by 457
Large sample variance of kappa in the case of different sets of raters.
Fleiss, J. L., Nee, J. C., & Landis, J. R. (1979) · Psychological Bulletin · doi:10.1037//0033-2909.86.5.974 · Cited by 398
Low-dose CT of the lungs: preliminary observations.
Naidich, D. P., Marshall, C. H., Gribbin, C., Arams, R. S., & McCauley, D. I. (1990) · Radiology · doi:10.1148/radiology.175.3.2343122 · Cited by 339 · cited 2×
“[10], who obtained diagnostic-quality images of the lung with settings as low as 20 mAs, although noise degraded image quality of mediastinal structures.”
BackgroundRadiology's Achilles' heel: error and variation in the interpretation of the Röntgen image.
Robinson, P. J. (1997) · The British Journal of Radiology · doi:10.1259/bjr.70.839.9536897 · Cited by 320
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217 · cited 2×
“Radiation exposure is particularly worrisome in children, in whom absorbed CT dose is more uniform, effective dose is higher, and risk of radiation-induced damage is considered greater than in adults [21, 22].”
BackgroundRothenberg, L. N., & Pentlow, K. S. (1992) · RadioGraphics · doi:10.1148/radiographics.12.6.1439023 · Cited by 192
Cited by
British Thoracic Society guideline for non-CFbronchiectasis
Pasteur, M. C., Bilton, D., Hill, A. T., & on behalf of the British Thoracic Society Bronchiectasis (non-CF) Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.136119 · Cited by 1,046
Computed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know
Frush, D. P., Donnelly, L. F., & Rosen, N. S. (2003) · Pediatrics · doi:10.1542/peds.112.4.951 · Cited by 625
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology
Khong, P.-L., Ringertz, H., Donoghue, V., Frush, D., Rehani, M., Appelgate, K., & Sanchez, R. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.10.001 · Cited by 363
Strauss, K. J., Goske, M. J., Kaste, S. C., Bulas, D., Frush, D. P., Butler, P., Morrison, G., Callahan, M. J., & Applegate, K. E. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4091 · Cited by 305
Siegel, M. J., Schmidt, B., Bradley, D., Suess, C., & Hildebolt, C. (2004) · Radiology · doi:10.1148/radiol.2332032107 · Cited by 294
Heyer, C. M., Mohr, P. S., Lemburg, S. P., Peters, S. A., & Nicolas, V. (2007) · Radiology · doi:10.1148/radiol.2452061919 · Cited by 274
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton-Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
Fricke, B. L., Donnelly, L. F., Frush, D. P., Yoshizumi, T., Varchena, V., Poe, S. A., & Lucaya, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800407 · Cited by 183
Self-citationde Jong, P. A., Ottink, M. D., Robben, S. G. F., Lequin, M. H., Hop, W. C. J., Hendriks, J. J. E., Paré, P. D., & Tiddens, H. A. W. M. (2004) · Radiology · doi:10.1148/radiol.2312021393 · Cited by 171
Lell, M. M., May, M., Deak, P., Alibek, S., Kuefner, M., Kuettner, A., Köhler, H., Achenbach, S., Uder, M., & Radkow, T. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f33b1d · Cited by 166
Zanetti, G., Marchiori, E., Gasparetto, T. D., Escuissato, D. L., & Soares Souza, A. (2007) · Pediatric Radiology · doi:10.1007/s00247-007-0603-1 · Cited by 72
“Lucaya et al. [ 15 ] concluded that low-dose high-resolution CT (25–50 mAs) provides a significant reduction in radiation dose with good-quality images of the lungs in children compared with the images from standard-dose CT.”
Background
Metadata
- Authors
- Lucaya, J., Piqueras, J., García-Peña, P., Enríquez, G., García-Macías, M., & Sotil, J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2000-10
- Volume
- 175
- Issue
- 4
- Pages
- 985-992
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2159972375
- Cited by
- 165
- References
- 15
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.