Coronary Artery Calcium Measurement: Agreement of Multirow Detector and Electron Beam CT

Becker, Christoph R., Kleffel, Timm, Crispin, Alexander, Knez, Andreas, Young, Jason, Schoepf, U. Joseph, Haberl, Ralph, Reiser, Maximilian F.·2001·American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of our study was to establish the most suitable algorithm to compare coronary artery calcium measurements performed with electron beam CT and multirow detector CT for the assessment of coronary artery disease. SUBJECTS AND METHODS: Coronary artery screening was performed in 100 patients with both electron beam and multirow detector CT. The images were transferred to a dedicated workstation for determination of the calcium score, volume, mass, density, and number of lesions. In addition to the traditional threshold of 130 H, the score of multirow detector CT studies was reevaluated at a threshold of 90 H. Fifty-nine of the patients underwent conventional coronary catheterization. Receiver operating characteristic curve analysis of the different scoring algorithms for detection of significant coronary artery stenosis was performed. RESULTS: The correlation between electron beam CT and multirow detector CT was high for every quantification algorithm. Determination of the score and the number of lesions with multirow detector CT revealed a systematic error of the measurement compared with electron beam CT. The areas under the curve in the receiver operating characteristic curve analyses for electron beam and multirow detector CT were similar for the score, volume, and mass, whereas they were lower for the density. No significant difference was found for the areas under the curve between scores using a 130-H and those using a 90-H threshold. CONCLUSION: Volume and mass indexes are superior to the traditional score, density, and number of lesions for comparing the results of electron beam and multirow detector CT and for determining significant coronary artery disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.176.5.1761295

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 282

Metadata

Authors
Becker, C. R., Kleffel, T., Crispin, A., Knez, A., Young, J., Schoepf, U. J., Haberl, R., & Reiser, M. F.
Venue
American Journal of Roentgenology
Published
2001-05
Volume
176
Issue
5
Pages
1295-1298
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2102742963
Cited by
282
References
2
FWCI
23.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coronary Artery Calcium Measurement: Agreement of Multirow Detector and Electron Beam CT. https://app.cochat.ai/papers/10.2214/ajr.176.5.1761295
The paper
Becker, C. R., Kleffel, T., Crispin, A., Knez, A., Young, J., Schoepf, U. J., Haberl, R., & Reiser, M. F. (2001). Coronary Artery Calcium Measurement: Agreement of Multirow Detector and Electron Beam CT. American Journal of Roentgenology. https://doi.org/10.2214/ajr.176.5.1761295

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.