Coronary Artery Calcium Measurement: Agreement of Multirow Detector and Electron Beam CT
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of our study was to establish the most suitable algorithm to compare coronary artery calcium measurements performed with electron beam CT and multirow detector CT for the assessment of coronary artery disease. SUBJECTS AND METHODS: Coronary artery screening was performed in 100 patients with both electron beam and multirow detector CT. The images were transferred to a dedicated workstation for determination of the calcium score, volume, mass, density, and number of lesions. In addition to the traditional threshold of 130 H, the score of multirow detector CT studies was reevaluated at a threshold of 90 H. Fifty-nine of the patients underwent conventional coronary catheterization. Receiver operating characteristic curve analysis of the different scoring algorithms for detection of significant coronary artery stenosis was performed. RESULTS: The correlation between electron beam CT and multirow detector CT was high for every quantification algorithm. Determination of the score and the number of lesions with multirow detector CT revealed a systematic error of the measurement compared with electron beam CT. The areas under the curve in the receiver operating characteristic curve analyses for electron beam and multirow detector CT were similar for the score, volume, and mass, whereas they were lower for the density. No significant difference was found for the areas under the curve between scores using a 130-H and those using a 90-H threshold. CONCLUSION: Volume and mass indexes are superior to the traditional score, density, and number of lesions for comparing the results of electron beam and multirow detector CT and for determining significant coronary artery disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Wexler, L., Brundage, B., Crouse, J., Detrano, R., Fuster, V., Maddahi, J., Rumberger, J., Stanford, W., White, R., & Taubert, K. (1996) · Circulation · doi:10.1161/01.cir.94.5.1175 · Cited by 1,070
Sangiorgi, G., Rumberger, J. A., Severson, A., Edwards, W. D., Gregoire, J., Fitzpatrick, L. A., & Schwartz, R. S. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00443-9 · Cited by 1,010
Raggi, P., Callister, T. Q., Cooil, B., He, Z.-X., Lippolis, N. J., Russo, D. J., Zelinger, A., & Mahmarian, J. J. (2000) · Circulation · doi:10.1161/01.cir.101.8.850 · Cited by 835
O’Rourke, R. A., Brundage, B. H., Froelicher, V. F., Greenland, P., Grundy, S. M., Hachamovitch, R., Pohost, G. M., Shaw, L. J., Weintraub, W. S., Winters, W. L., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00831-7 · Cited by 791
Callister, T. Q., Cooil, B., Raya, S. P., Lippolis, N. J., Russo, D. J., & Raggi, P. (1998) · Radiology · doi:10.1148/radiology.208.3.9722864 · Cited by 750
Callister, T. Q., Raggi, P., Cooil, B., Lippolis, N. J., & Russo, D. J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392703 · Cited by 682
O’Rourke, R. A., Brundage, B. H., Froelicher, V. F., Greenland, P., Grundy, S. M., Hachamovitch, R., Pohost, G. M., Shaw, L. J., Weintraub, W. S., Winters, W. L., et al. (2000) · Circulation · doi:10.1161/01.cir.102.1.126 · Cited by 508
Coronary artery calcification: assessment with electron beam CT and histomorphometric correlation.
Mautner, G. C., Mautner, S. L., Froehlich, J., Feuerstein, I. M., Proschan, M. A., Roberts, W. C., & Doppman, J. L. (1994) · Radiology · doi:10.1148/radiology.192.3.8058924 · Cited by 348
O’Malley, P. G., Taylor, A. J., Jackson, J. L., Doherty, T. M., & Detrano, R. C. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00906-6 · Cited by 293
Hong, C., Becker, C. R., Huber, A., Schoepf, U. J., Ohnesorge, B., Knez, A., Brüning, R., & Reiser, M. F. (2001) · Radiology · doi:10.1148/radiol.2203010055 · Cited by 255
Self-citationHong, C., Becker, C. R., Schoepf, U. J., Ohnesorge, B., Bruening, R., & Reiser, M. F. (2002) · Radiology · doi:10.1148/radiol.2232010919 · Cited by 193
Self-citationLaudon, D. A., Vukov, L. F., Breen, J. F., Rumberger, J. A., Wollan, P. C., & Sheedy, P. F. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)70412-9 · Cited by 178
Willmann, J. K., Weishaupt, D., Lachat, M. L., Kobza, R., Roos, J. E., Seifert, B., Lüscher, T. F., Marinček, B., & Hilfiker, P. R. (2002) · Radiology · doi:10.1148/radiol.2251011703 · Cited by 171
Calcification of coronary arteries: detection and quantification with double-helix CT.
Shemesh, J., Apter, S., Rozenman, J., Lusky, A., Rath, S., Itzchak, Y., & Motro, M. (1995) · Radiology · doi:10.1148/radiology.197.3.7480756 · Cited by 165
Wang, S., Detrano, R., Secci, A., Tang, W., Doherty, T. M., Puentes, G., Wong, N. D., & Brundage, B. H. (1996) · American Heart Journal · doi:10.1016/s0002-8703(96)90237-9 · Cited by 142
Becker, C. R., Jakobs, T. F., Aydemir, S., Becker, A., Knez, A., Schoepf, U. J., Bruening, R. D., Haberl, R., & Reiser, M. F. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.2.1740543 · Cited by 138
Self-citationCoronary artery calcium: Alternate methods for accurate and reproducible quantitation
Yoon, H., Greaser, L. E., Mather, R. T., Sinha, S., McNitt‐Gray, M. F., & Goldin, J. G. (1997) · Academic Radiology · doi:10.1016/s1076-6332(97)80137-7 · Cited by 110
Budoff, M. J., Mao, S., Zalace, C. P., Bakhsheshi, H., & Oudiz, R. J. (2001) · International Journal of Cardiology · doi:10.1016/s0167-5273(00)00449-6 · Cited by 46
Atherothrombotic plaques and the need for imaging
Fayad, Z. A., & Fuster, V. (2002) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(02)00017-5 · Cited by 12
Cited by
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationBudoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Diagnostic and Prognostic Value of Absence of Coronary Artery Calcification
Sarwar, A., Shaw, L. J., Shapiro, M. D., Blankstein, R., Hoffman, U., Cury, R. C., Abbara, S., Brady, T. J., Budoff, M. J., Blumenthal, R. S., et al. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.12.031 · Cited by 679
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Self-citationClinical Imaging of the High-Risk or Vulnerable Atherosclerotic Plaque
Fayad, Z. A., & Fuster, V. (2001) · Circulation Research · doi:10.1161/hh1601.095596 · Cited by 518
Metadata
- Authors
- Becker, C. R., Kleffel, T., Crispin, A., Knez, A., Young, J., Schoepf, U. J., Haberl, R., & Reiser, M. F.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-05
- Volume
- 176
- Issue
- 5
- Pages
- 1295-1298
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2102742963
- Cited by
- 282
- References
- 24
- FWCI
- 23.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.