Coronary Artery Calcium Measurement: Agreement of Multirow Detector and Electron Beam CT
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of our study was to establish the most suitable algorithm to compare coronary artery calcium measurements performed with electron beam CT and multirow detector CT for the assessment of coronary artery disease. SUBJECTS AND METHODS: Coronary artery screening was performed in 100 patients with both electron beam and multirow detector CT. The images were transferred to a dedicated workstation for determination of the calcium score, volume, mass, density, and number of lesions. In addition to the traditional threshold of 130 H, the score of multirow detector CT studies was reevaluated at a threshold of 90 H. Fifty-nine of the patients underwent conventional coronary catheterization. Receiver operating characteristic curve analysis of the different scoring algorithms for detection of significant coronary artery stenosis was performed. RESULTS: The correlation between electron beam CT and multirow detector CT was high for every quantification algorithm. Determination of the score and the number of lesions with multirow detector CT revealed a systematic error of the measurement compared with electron beam CT. The areas under the curve in the receiver operating characteristic curve analyses for electron beam and multirow detector CT were similar for the score, volume, and mass, whereas they were lower for the density. No significant difference was found for the areas under the curve between scores using a 130-H and those using a 90-H threshold. CONCLUSION: Volume and mass indexes are superior to the traditional score, density, and number of lesions for comparing the results of electron beam and multirow detector CT and for determining significant coronary artery disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016 · cited 1×
“Comparison of the receiver operating characteristic curves from electron beam CT and multirow detector CT included calculation of the difference between the area under the curve and the p value [ 13 ].”
MethodBasic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Wexler, L., Brundage, B., Crouse, J., Detrano, R., Fuster, V., Maddahi, J., Rumberger, J., Stanford, W., White, R., & Taubert, K. (1996) · Circulation · doi:10.1161/01.cir.94.5.1175 · Cited by 1,070
Sangiorgi, G., Rumberger, J. A., Severson, A., Edwards, W. D., Gregoire, J., Fitzpatrick, L. A., & Schwartz, R. S. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00443-9 · Cited by 1,010
Raggi, P., Callister, T. Q., Cooil, B., He, Z.-X., Lippolis, N. J., Russo, D. J., Zelinger, A., & Mahmarian, J. J. (2000) · Circulation · doi:10.1161/01.cir.101.8.850 · Cited by 835
O’Rourke, R. A., Brundage, B. H., Froelicher, V. F., Greenland, P., Grundy, S. M., Hachamovitch, R., Pohost, G. M., Shaw, L. J., Weintraub, W. S., Winters, W. L., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00831-7 · Cited by 791
Callister, T. Q., Cooil, B., Raya, S. P., Lippolis, N. J., Russo, D. J., & Raggi, P. (1998) · Radiology · doi:10.1148/radiology.208.3.9722864 · Cited by 750
Cited by
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationBudoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Diagnostic and Prognostic Value of Absence of Coronary Artery Calcification
Sarwar, A., Shaw, L. J., Shapiro, M. D., Blankstein, R., Hoffman, U., Cury, R. C., Abbara, S., Brady, T. J., Budoff, M. J., Blumenthal, R. S., et al. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.12.031 · Cited by 679
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Self-citationClinical Imaging of the High-Risk or Vulnerable Atherosclerotic Plaque
Fayad, Z. A., & Fuster, V. (2001) · Circulation Research · doi:10.1161/hh1601.095596 · Cited by 518
Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CT
Hunold, P., Vogt, F. M., Schmermund, A., Debatin, J. F., Kerkhoff, G., Budde, T., Erbel, R., Ewen, K., & Barkhausen, J. (2003) · Radiology · doi:10.1148/radiol.2261011365 · Cited by 405
Achenbach, S., Ropers, D., Pohle, K., Leber, A., Thilo, C., Knez, A., Menendez, T., Maeffert, R., Kusus, M., Regenfus, M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000027567.49283.ff · Cited by 339
Self-citationCoronary Artery Calcium Scanning
Hecht, H. S. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.02.006 · Cited by 305
Fayad, Z. A., Fuster, V., Nikolaou, K., & Becker, C. (2002) · Circulation · doi:10.1161/01.cir.0000034392.34211.fc · Cited by 276
Self-citationColes, D. R., Smail, M. A., Negus, I. S., Wilde, P., Oberhoff, M., Karsch, K. R., & Baumbach, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.078 · Cited by 265
Cleary, P. A., Orchard, T. J., Genuth, S., Wong, N. D., Detrano, R., Backlund, J.-Y. C., Zinman, B., Jacobson, A., Sun, W., Lachin, J. M., et al. (2006) · Diabetes · doi:10.2337/db06-0653 · Cited by 264
Hong, C., Becker, C. R., Huber, A., Schoepf, U. J., Ohnesorge, B., Knez, A., Brüning, R., & Reiser, M. F. (2001) · Radiology · doi:10.1148/radiol.2203010055 · Cited by 255
Self-citationKuettner, A., Kopp, A. F., Schroeder, S., Rieger, T., Brunn, J., Meisner, C., Heuschmid, M., Trabold, T., Burgstahler, C., Martensen, J., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.05.015 · Cited by 228
Calcification in atherosclerosis
Alexopoulos, N., & Raggi, P. (2009) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2009.165 · Cited by 226
Young Obese Women with Polycystic Ovary Syndrome Have Evidence of Early Coronary Atherosclerosis
Shroff, R., Kerchner, A., Maifeld, M., Van Beek, E. J. R., Jagasia, D., & Dokras, A. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-1343 · Cited by 194
“CAC correlates with the extent of coronary atherosclerotic plaque and can be quantified by modalities such as electronbeamCTandMSCT.MSCTusesarotatinggantrywithaspecial x-ray tube and variable number of detectors (from 4 to 64), with images acquired over 165–420 msec at 0.5- to 3.0-mm intervals, andcorrelateswellwithCA…”
MethodInfluentialHong, C., Becker, C. R., Schoepf, U. J., Ohnesorge, B., Bruening, R., & Reiser, M. F. (2002) · Radiology · doi:10.1148/radiol.2232010919 · Cited by 193
Self-citationOhnesorge, B., Flohr, T., Fischbach, R., Kopp, A., Knez, A., Schröder, S., Schöpf, U., Crispin, A., Klotz, E., Reiser, M., et al. (2002) · European Radiology · doi:10.1007/s00330-002-1394-2 · Cited by 185
Self-citationHorton, K. M., Post, W. S., Blumenthal, R. S., & Fishman, E. K. (2002) · Circulation · doi:10.1161/01.cir.0000027136.56615.de · Cited by 178
Hong, C., Bae, K. T., & Pilgram, T. K. (2003) · Radiology · doi:10.1148/radiol.2273020369 · Cited by 169
da Luz, P. L., Bertini, P. J., & Favarato, D. (2005) · Clinics · doi:10.1590/s1807-59322005000500011 · Cited by 13
Franco, L. F., Szarf, G., Dotto, R. P., Dib, S. A., Moises, R. S., Giuffrida, F. M. A., & Reis, A. F. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108867 · Cited by 9
Metadata
- Authors
- Becker, C. R., Kleffel, T., Crispin, A., Knez, A., Young, J., Schoepf, U. J., Haberl, R., & Reiser, M. F.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-05
- Volume
- 176
- Issue
- 5
- Pages
- 1295-1298
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2102742963
- Cited by
- 282
- References
- 24
- FWCI
- 23.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.