CoChat

CT and Pathologic Assessment of Prospective Nodal Staging in Patients with Ductal Adenocarcinoma of the Head of the Pancreas

Roche, Clare J., Hughes, Mark L., Garvey, Conall J., Campbell, Fiona, White, Donagh A., Jones, Lucie, Neoptolemos, John P. · 2003 · American Journal of Roentgenology
Cited by 184

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The aim of our study was to compare the assessment of peripancreatic lymph nodes using CT with the gold standard of detailed histopathologic assessment of resected specimens in patients with pancreatic ductal adenocarcinoma. SUBJECTS AND METHODS: Sixty-two patients with presumed pancreatic carcinoma were prospectively studied with dual-phase contrast-enhanced helical CT, and images were interpreted in consensus by three radiologists. Complete surgical resection was performed in 28 patients. A detailed nodal classification system was used for radiologic, surgical, and pathologic staging in the nine patients whose final diagnosis at histology was pancreatic ductal adenocarcinoma. RESULTS: Forty lymph nodes were prospectively identified on CT in these nine patients. Two of 23 nodes (9%) measuring less than 5 mm in the short-axis diameter were malignant, four of 11 nodes (36%) measuring 5-10 mm were malignant, and one of six nodes (17%) larger than 10 mm was malignant. Using a short-axis diameter of greater than 10 mm as the criterion for nodal involvement, we found a sensitivity of 14% (1/7) and a specificity of 85% (28/33), with a positive predictive value of 17% (1/6), a negative predictive value of 82% (28/34), and an overall accuracy of 73% (29/40). Ovoid nodal shape, clustering of nodes, and the absence of a fatty hilum were not useful predictors of malignancy on CT. CONCLUSION: In resectable pancreatic ductal adenocarcinoma, CT is not accurate overall for the prediction of nodal involvement. In a patient with presumed pancreatic carcinoma that is considered to be resectable, the depiction on CT of peripancreatic nodes should not prevent attempted curative resection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.180.2.1800475

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

Metadata

Authors
Roche, C. J., Hughes, M. L., Garvey, C. J., Campbell, F., White, D. A., Jones, L., & Neoptolemos, J. P.
Venue
American Journal of Roentgenology
Published
2003-02
Volume
180
Issue
2
Pages
475-480
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2041894267
Cited by
184
References
29
FWCI
4.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.