Universal Use of Nonionic Iodinated Contrast Medium for CT: Evaluation of Safety in a Large Urban Teaching Hospital
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We evaluated the safety of the universal use of the nonionic iodinated contrast agent iopromide in patients undergoing CT in a large urban teaching hospital. SUBJECTS AND METHODS: For 2 years, we prospectively recorded all adverse events temporally associated with the administration of iopromide in 29,508 consecutive patients undergoing contrast-enhanced CT at our institution. The types, intensities, treatments, and outcomes of adverse events were recorded along with relevant patient history, including risk factors. Descriptive analyses of the variables, comparisons of means, and proportions using Student's t and chi-square tests, and logistic regressions were conducted. RESULTS: Adverse events were observed in 211 patients (0.7%) and were categorized as follows: urticaria (n = 161), facial or laryngeal edema (n = 13), bronchospasm (n = 8), severe nausea or vomiting (n = 10), or other (n = 19). One hundred eighty-eight adverse events (89%) were rated mild, 19 moderate (9%), and four severe (2%), including one fatality. Adverse events required treatment in 89 patients (42%). A history of allergy was present in 92 patients (44%), and 29 (14%) had a prior contrast reaction. Other relevant risk factors were identified in 63 patients (30%). No relationship existed between the occurrence of adverse events and any of the following: patient age, dose of iodine administered, or time of study (i.e., month, season, and year). Women (p < 0.001) and outpatients (p < 0.001) had a statistically significant higher incidence of adverse events. CONCLUSION: The universal use of iopromide as an IV CT contrast agent has a favorable safety profile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Katayama, H., Yamaguchi, K., Kozuka, T., Takashima, T., Seez, P., & Matsuura, K. (1990) · Radiology · doi:10.1148/radiology.175.3.2343107 · Cited by 1,474 · cited 3×
“[21], and Cochran et al.”
BackgroundTrends in Adverse Events After IV Administration of Contrast Media
Cochran, S. T., Bomyea, K., & Sayre, J. W. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.6.1761385 · Cited by 358 · cited 5×
“Urticaria and facial or laryngeal edema accounted for most (> 90%) of the adverse events [18].”
BackgroundResultInfluentialEmerging techniques: Whole‐body screening and staging with MRI
Lauenstein, T. C., & Semelka, R. C. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20666 · Cited by 69
Whole-Body Magnetic Resonance Imaging
Lauenstein, T. C., & Semelka, R. C. (2005) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000181120.44859.63 · Cited by 18
Dawson, P. (1995) · Side effects of drugs annual · doi:10.1016/s0378-6080(05)80171-0 · Cited by 3 · cited 2×
“1% [17–21].”
BackgroundDawson, P. (1998) · Side effects of drugs annual · doi:10.1016/s0378-6080(98)80050-0 · Cited by 2
Cited by
Diagnosis, Evaluation and Follow-Up of Asymptomatic Microhematuria (AMH) in Adults: AUA Guideline
Davis, R., Jones, J. S., Barocas, D. A., Castle, E. P., Lang, E. K., Leveillee, R. J., Messing, E. M., Miller, S. D., Peterson, A. C., Turk, T. M. T., et al. (2012) · Journal of Urology · doi:10.1016/j.juro.2012.09.078 · Cited by 482
Clinical Practice Guideline: Hoarseness (Dysphonia)
Schwartz, S. R., Cohen, S. M., Dailey, S. H., Rosenfeld, R. M., Deutsch, E. S., Gillespie, M. B., Granieri, E., Hapner, E. R., Kimball, C. E., Krouse, H. J., et al. (2009) · Otolaryngology–Head and Neck Surgery · doi:10.1016/j.otohns.2009.06.744 · Cited by 453
Clinical Practice Guideline: Hoarseness (Dysphonia) (Update)
Stachler, R. J., Francis, D. O., Schwartz, S. R., Damask, C. C., Digoy, G. P., Krouse, H. J., McCoy, S. J., Ouellette, D. R., Patel, R. R., Reavis, C. (. W., et al. (2018) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599817751030 · Cited by 368
“1% of people receiving iodinated contrast material, with a death rate of up to 1 in 29,500 people.(198,199) While MRI has no radiation effects, it is not without risk.”
BackgroundVerberne, H. J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., Buechel, R. R., Cuocolo, A., van Eck-Smit, B. L. F., Flotats, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3139-x · Cited by 366
Safe Use of Contrast Media: What the Radiologist Needs to Know
Beckett, K. R., Moriarity, A. K., & Langer, J. M. (2015) · RadioGraphics · doi:10.1148/rg.2015150033 · Cited by 334
Frequency, Outcome, and Appropriateness of Treatment of Nonionic Iodinated Contrast Media Reactions
Wang, C. L., Cohan, R. H., Ellis, J. H., Caoili, E. M., Wang, G., & Francis, I. R. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3421 · Cited by 306
Dillman, J. R., Ellis, J. H., Cohan, R. H., Strouse, P. J., & Jan, S. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2554 · Cited by 303
“This is not dissimilar to results presented in other studies that evaluated both gadolinium-containing and iodinated contrast material allergic-like reactions [13–15, 18, 19, 21, 22].”
BackgroundResultYeh, B. M., FitzGerald, P. F., Edic, P. M., Lambert, J. W., Colborn, R. E., Marino, M. E., Evans, P. M., Roberts, J. C., Wang, Z. J., Wong, M. J., et al. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.09.001 · Cited by 219
“Iodinated agents have an excellent safety record [114,115] but small subsets of patients may be susceptible to injury [116].”
BackgroundHan, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Metadata
- Authors
- Mortelé, K. J., Oliva, M.-R., Ondategui, S., Ros, P. R., & Silverman, S. G.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2005-01
- Volume
- 184
- Issue
- 1
- Pages
- 31-34
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2002439878
- Cited by
- 209
- References
- 6
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.