CoChat

Performance of HbA1c as an Early Diagnostic Indicator of Type 1 Diabetes in Children and Youth

Open access
Vehik, Kendra, Cuthbertson, David, Boulware, David, Beam, Craig A., Rodriguez, Henry, Legault, Laurent, Hyytinen, Mila, Rewers, Marian J., Schatz, Desmond A., Krischer, Jeffrey P., the TEDDY, TRIGR, Diabetes Prevention Trial–Type 1, and Type 1 Diabetes TrialNet Natural History Study Groups · 2012 · Diabetes Care
Cited by 48

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The aim of this study was to evaluate HbA1c as an alternative criterion for impaired glucose tolerance (IGT) or type 1 diabetes (T1D) in high-risk subjects <21 years of age. RESEARCH DESIGN AND METHODS: Subjects <21 years of age who participated in the prospective DPT-1, TEDDY, TRIGR, and Type 1 Diabetes TrialNet Natural History (TrialNet) studies and had an HbA1c within 90 days of an OGTT with a 2-h plasma glucose (2-hPG) measure were included. An OGTT of 140–199 mg/dL defined IGT, and an OGTT with 2-hPG ≥200 mg/dL or fasting plasma glucose ≥126 mg/dL defined diabetes. HbA1c ≥5.7% defined IGT, and HbA1c ≥ 6.5% defined diabetes. Receiver-operating characteristic curve analysis was used to assess diagnostic accuracy of HbA1c compared with OGTT. RESULTS: There were 587 subjects from DPT-1, 884 from TrialNet, 91 from TEDDY, and 420 from TRIGR. As an indicator for IGT, HbA1c sensitivity was very low across the studies (8–42%), and specificity was variable (64–95%). With HbA1c ≥6.5% threshold used for T1D diagnosis, the sensitivity was very low and specificity was high (sensitivity and specificity: DPT-1 24 and 98%, TrialNet 28 and 99%, TEDDY 34 and 98%, and TRIGR 33 and 99%, respectively). The positive predictive value of HbA1c ≥6.5% for the development of T1D was variable (50–94%) across the four studies. CONCLUSIONS: HbA1c ≥6.5% is a specific but not sensitive early indicator for T1D in high-risk subjects <21 years of age diagnosed by OGTT or asymptomatic hyperglycemia. Redefining the HbA1c threshold is recommended if used as an alternative criterion in diagnosing T1D.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc12-0111

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Vehik, K., Cuthbertson, D., Boulware, D., Beam, C. A., Rodriguez, H., Legault, L., Hyytinen, M., Rewers, M. J., Schatz, D. A., Krischer, J. P., & the TEDDY, T.
Venue
Diabetes Care
Published
2012-08-14
Volume
35
Issue
9
Pages
1821-1825
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2126597885
Cited by
48
References
6
FWCI
1.59
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.