Evidence of a Strong Association Between Frequency of Self-Monitoring of Blood Glucose and Hemoglobin A1c Levels in T1D Exchange Clinic Registry Participants
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Despite substantial evidence of the benefit of frequent self-monitoring of blood glucose (SMBG) in type 1 diabetes, certain insurers limit the number of test strips that they will provide. The large database of the T1D Exchange clinic registry provided an opportunity to evaluate the relationship between the number of SMBG measurements per day and HbA1c levels across a wide age range of children and adults. RESEARCH DESIGN AND METHODS: The analysis included 20,555 participants in the T1D Exchange clinic registry with type 1 diabetes ≥1 year and not using a continuous glucose monitor (11,641 younger than age 18 years and 8,914 18 years old or older). General linear models were used to assess the association between the number of SMBG measurements and HbA1c levels after adjusting for potential confounding variables. RESULTS: A higher number of SMBG measurements per day were associated with non-Hispanic white race, insurance coverage, higher household income, and use of an insulin pump for insulin delivery (P < 0.001 for each factor). After adjusting for these factors, a higher number of SMBG measurements per day was strongly associated with a lower HbA1c level (adjusted P < 0.001), with the association being present in all age-groups and in both insulin pump and injection users. CONCLUSIONS: There is a strong association between higher SMBG frequency and lower HbA1c levels. It is important for insurers to consider that reducing restrictions on the number of test strips provided per month may lead to improved glycemic control for some patients with type 1 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A later study found a strong, continuous association of BGM frequency with improved glycemic control as measured by HbA 1c (150).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [150]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Monitoring of blood glucose less frequently than three to four times per day in adults and adolescents has been associated with less effective control of glycemia as measured by HbA 1c (150)(151)(152).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [150]
The cited source says what the claim attributes to it.
In the citing paper
“Testing more frequently than 10 times per day was not associated with greater control of glycemia as HbA 1c levels were similar in participants testing 10 to 12 times per day and in those testing 13 or more times per day (7.8% and 7.7%, respectively).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [150]
The cited source says what the claim attributes to it.
In the citing paper
“In registry studies, increased testing frequency is associated with lower HbA 1c (71).”
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The standard requires that 95% of values fall within ±15 mg/dL for glucose <100 mg/dL and within ±15% at ≥100 mg/dL.140,141”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [141]
Experimental — accuracy not yet measured
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Standards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
The T1D exchange clinic registry
Beck, R. W., Tamborlane, W. V., Bergenstal, R. M., Miller, K. M., DuBose, S. N., Hall, C. A., & for the T1D Exchange Clinic Network (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1561 · Cited by 456
Self-citationZiegler, R., Heidtmann, B., Hilgard, D., Hofer, S., Rosenbauer, J., Holl, R., & DPV-Wiss-Initiative, F. T. (2011) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2010.00650.x · Cited by 334
The DCCT Research Group (1986) · Diabetes · doi:10.2337/diab.35.5.530 · Cited by 331
Implementation of Treatment Protocols in the Diabetes Control and Complications Trial
Diabetes Control and Complications Trial Research Group (1995) · Diabetes Care · doi:10.2337/diacare.18.3.361 · Cited by 283
Predictors of glycemic control and short-term adverse outcomes in youth with type 1 diabetes
Levine, B.-S., Anderson, B. J., Butler, D. A., Antisdel, J. E., Brackett, J., & Laffel, L. M. B. (2001) · The Journal of Pediatrics · doi:10.1067/mpd.2001.116283 · Cited by 279
Schütt, M., Kern, Krause, U., Busch, Dapp, A., Grziwotz, Mayer, I., Rosenbauer, Wagner, C., Zimmermann, et al. (2006) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-2006-924152 · Cited by 218
Schiffrin, A., & Belmonte, M. (1982) · Diabetes Care · doi:10.2337/diacare.5.5.479 · Cited by 199
Predictors of control of diabetes: monitoring may be the key
Haller, M. J., Stalvey, M. S., & Silverstein, J. H. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2003.12.042 · Cited by 162
Self-citation
Cited by
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationKatsarou, A., Gudbjörnsdottir, S., Rawshani, A., Dabelea, D., Bonifacio, E., Anderson, B. J., Jacobsen, L. M., Schatz, D. A., & Lernmark, Å. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.16 · Cited by 1,475
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Self-citationType 1 Diabetes Through the Life Span: A Position Statement of the American Diabetes Association
Chiang, J. L., Kirkman, M. S., Laffel, L. M. B., Peters, A. L., & Authors, O. B. O. T. T. 1. D. S. (2014) · Diabetes Care · doi:10.2337/dc14-1140 · Cited by 965
Metadata
- Authors
- Miller, K. M., Beck, R. W., Bergenstal, R. M., Goland, R. S., Haller, M. J., McGill, J. B., Rodriguez, H., Simmons, J. H., Hirsch, I. B., & for the T1D Exchange Clinic Network
- Affiliations
- Jaeb Center for Health Research (US)
- Park Nicollet Clinic (US)
- Columbia University (US)
- University of Florida (US)
- Washington University in St. Louis (US)
- University of South Florida (US)
- Vanderbilt University Medical Center (US)
- University of Washington Medical Center (US)
- Corresponding author
- Miller, Kellee M.
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2013-06-12
- Volume
- 36
- Issue
- 7
- Pages
- 2009-2014
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC3687326
- OpenAlex
- W2134502275
- Semantic Scholar
- 4bb14094874795e605ed0ff17b4413221396175d
- Cited by
- 505
- References
- 10
- Citations by year
- 2026: 16 · 2025: 15 · 2024: 22 · 2023: 23 · 2022: 40 · 2021: 63 · 2020: 57 · 2019: 48 · 2018: 62 · 2017: 49 · 2016: 35 · 2015: 34 · 2014: 25 · 2013: 14
- FWCI
- 28.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes Care (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (UL1TR000439)
- National Institute of Diabetes and Digestive and Kidney Diseases (T32DK063687)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, self-monitoring of blood glucose, HbA1c, glycemic control, insurance coverage, insulin pump therapy, household income, racial disparities, children and adults
- MeSH terms
- Adolescent, Adult, Aged, Blood Glucose, Child, Child, Preschool, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Infant, Insulin Infusion Systems, Male, Middle Aged, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.