CoChat

Use of an Insulin Bolus Advisor Improves Glycemic Control in Multiple Daily Insulin Injection (MDI) Therapy Patients With Suboptimal Glycemic Control

Open access
Ziegler, Ralph, Cavan, David A., Cranston, Iain, Barnard, Katharine, Ryder, Jacqueline, Vogel, Claudia, Parkin, Christopher G., Koehler, Walter, Vesper, Iris, Petersen, Bettina, Schweitzer, Matthias A., Wagner, Robin S. · 2013 · Diabetes Care
Cited by 107

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Use of automated bolus advisors is associated with improved glycemic control in patients treated with insulin pump therapy. We conducted a study to assess the impact of using an insulin bolus advisor embedded in a blood glucose (BG) meter on glycemic control and treatment satisfaction in patients treated with multiple daily insulin injection (MDI) therapy. The study goal was to achieve >0.5% A1C reduction in most patients. RESEARCH DESIGN AND METHODS: This was a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 MDI-treated patients with poorly controlled diabetes (202 with type 1 diabetes, 16 with type 2 diabetes) who were 18 years of age or older. Participants had mean baseline A1C of 8.9% (SD, 1.2 [74 mmol/mol]), mean age of 42.4 years (SD, 14.0), mean BMI of 26.5 kg/m2 (SD, 4.2), and mean diabetes duration of 17.7 years (SD, 11.1). Control group (CNL) patients used a standard BG meter and manual bolus calculation; intervention group (EXP) patients used the Accu-Chek Aviva Expert meter with an integrated bolus advisor to calculate insulin dosages. Glucose data were downloaded and used for therapy parameter adjustments in both groups. RESULTS: A total of 193 patients (CNL, n = 93; EXP, n = 100) completed the study. Significantly more EXP than CNL patients achieved >0.5% A1C reduction (56.0% vs. 34.4%; P < 0.01). Improvement in treatment satisfaction (Diabetes Treatment Satisfaction Questionnaire scale) was significantly greater in EXP patients (11.4 [SD, 6.0] vs. 9.0 [SD, 6.3]; P < 0.01). Percentage of BG values <50 mg/dL was <2% in both groups during the study. CONCLUSIONS: Use of an automated bolus advisor resulted in improved glycemic control and treatment satisfaction without increasing severe hypoglycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc13-0251

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Ziegler, R., Cavan, D. A., Cranston, I., Barnard, K., Ryder, J., Vogel, C., Parkin, C. G., Koehler, W., Vesper, I., Petersen, B., Schweitzer, M. A., & Wagner, R. S.
Venue
Diabetes Care
Published
2013-10-15
Volume
36
Issue
11
Pages
3613-3619
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2166150562
Cited by
107
References
9
FWCI
8.25
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.