Optimizing Hybrid Closed-Loop Therapy in Adolescents and Emerging Adults Using the MiniMed 670G System
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The MiniMed 670G System is the first commercial hybrid closed-loop (HCL) system for management of type 1 diabetes. Using data from adolescent and young adult participants, we compared insulin delivery patterns and time-in-range metrics in HCL (Auto Mode) and open loop (OL). System alerts, usage profiles, and operational parameters were examined to provide suggestions for optimal clinical use of the system. RESEARCH DESIGN AND METHODS: Data from 31 adolescent and young adult participants (14–26 years old) at three clinical sites in the 670G pivotal trial were analyzed. Participants had a 2-week run-in period in OL, followed by a 3-month in-home study phase with HCL functionality enabled. Data were compared between baseline OL and HCL use after 1 week, 1 month, 2 months, and 3 months. RESULTS: Carbohydrate-to-insulin (C-to-I) ratios were more aggressive for all meals with HCL compared with baseline OL. Total daily insulin dose and basal-to-bolus ratio did not change during the trial. Time in range increased 14% with use of Auto Mode after 3 months (P < 0.001), and HbA1c decreased 0.75%. Auto Mode exits were primarily due to sensor/insulin delivery alerts and hyperglycemia. The percentage of time in Auto Mode gradually declined from 87%, with a final use rate of 72% (−15%). CONCLUSIONS: In transitioning young patients to the 670G system, providers should anticipate immediate C-to-I ratio adjustments while also assessing active insulin time. Users should anticipate occasional Auto Mode exits, which can be reduced by following system instructions and reliably bolusing for meals. Unique 670G system functionality requires ongoing clinical guidance and education from providers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Self-citation(2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.193 · Cited by 653
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644 · cited 7×
“1% (61 to 54 mmol/mol), occurred in those aged 14–21 years (15).”
BackgroundMethodInfluentialSelf-citationGarg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · cited 6×
“As in previous studies (15,16), time in range was significantly improved using HCL compared with OL insulin delivery.”
BackgroundMethodInfluentialSelf-citationComing of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
Outcome measures for artificial pancreas clinical trials: a consensus report
Maahs, D. M., Buckingham, B. A., Castle, J. R., Cinar, A., Damiano, E. R., Dassau, E., DeVries, J. H., Doyle, F. J., Griffen, S. C., Haidar, A., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2716 · Cited by 211 · cited 1×
“Target range was considered to be 70–180 mg/dL as per AP consensus reporting guidelines (21).”
BackgroundSelf-citation
Cited by
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationForlenza, G. P., Li, Z., Buckingham, B. A., Pinsker, J. E., Cengiz, E., Wadwa, R. P., Ekhlaspour, L., Church, M. M., Weinzimer, S. A., Jost, E., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0771 · Cited by 246
Self-citationBenhamou, P.-Y., Franc, S., Reznik, Y., Thivolet, C., Schaepelynck, P., Renard, E., Guerci, B., Chaillous, L., Lukas-Croisier, C., Jeandidier, N., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30003-2 · Cited by 217
One year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215
“Prior insulin delivery systems Animas 13 (9) 3 (8) 10 (10) Medtronic, older 62 (45) 19 (49) 43 (44) Medtronic 630G 37 (27) 13 (33) 24 (24) Omnipod 5 (4) 1 (3) 4 (4) Roche 1 (1) 0 (0) 1 (1) Tandem 4 (3) 0 (0) 4 (4) Multiple daily injections 4 (3) 1 (3) 3 (3) Other 11 (8) 2 (5) 9 (9)”
BackgroundSelf-citationPositioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
Real-World Patient-Reported Outcomes and Glycemic Results with Initiation of Control-IQ Technology
Pinsker, J. E., Müller, L., Constantin, A., Leas, S., Manning, M., McElwee Malloy, M., Singh, H., & Habif, S. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0388 · Cited by 147
“22,23 Control-IQ technology has only one reason for automation to cease (loss of CGM connectivity for 20 or more minutes), and automatically resumes automation as soon as valid CGM values are received with no need for the user to switch on or activate automation in any way.”
A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Isganaitis, E., Raghinaru, D., Ambler-Osborn, L., Pinsker, J. E., Buckingham, B. A., Wadwa, R. P., Ekhlaspour, L., Kudva, Y. C., Levy, C. J., Forlenza, G. P., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0572 · Cited by 115
Self-citationA clinical guide to advanced diabetes devices and closed-loop systems using the CARES paradigm
Messer, L. H., Berget, C., & Forlenza, G. P. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0105 · Cited by 100
Self-citationArtificial intelligence/machine learning in diabetes care
Singla, R., Singla, A., Gupta, Y., & Kalra, S. (2019) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/ijem.ijem_228_19 · Cited by 52
Efficacy of hybrid closed-loop system in adults with type 1 diabetes and gastroparesis
Kaur, H., Schneider, N., Pyle, L., Campbell, K., Akturk, H. K., & Shah, V. N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0254 · Cited by 24
Giza, S., Kotanidou, E. P., Tsinopoulou, V. R., Poukoulidou, T., Ntouma, S., & Galli-Tsinopoulou, A. (2025) · Children · doi:10.3390/children12121668 · Cited by 7
Metadata
- Authors
- Messer, L. H., Forlenza, G. P., Sherr, J. L., Wadwa, R. P., Buckingham, B. A., Weinzimer, S. A., Maahs, D. M., & Slover, R. H.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2018-02-14
- Volume
- 41
- Issue
- 4
- Pages
- 789-796
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2791100815
- Cited by
- 126
- References
- 7
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.