The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Investigation of the Accuracy of 18 Marketed Blood Glucose Monitors
Abstract
OBJECTIVE: Cleared blood glucose monitors (BGMs) for personal use may not always deliver levels of accuracy currently specified by international and U.S. regulatory bodies. This study’s objective was to assess the accuracy of 18 such systems cleared by the U.S. Food and Drug Administration representing approximately 90% of commercially available systems used from 2013 to 2015. RESEARCH DESIGN AND METHODS: A total of 1,035 subjects were recruited to have a capillary blood glucose (BG) level measured on six different systems and a reference capillary sample prepared for plasma testing at a reference laboratory. Products were obtained from consumer outlets and tested in three triple-blinded studies. Each of the three participating clinical sites tested a different set of six systems for each of the three studies in a round-robin. In each study, on average, a BGM was tested on 115 subjects. A compliant BG result was defined as within 15% of a reference plasma value (for BG ≥100 mg/dL [5.55 mmol/L]) or within 15 mg/dL (0.83 mmol/L) (for BG <100 mg/dL [5.55 mmol/L]). The proportion of compliant readings in each study was compared against a predetermined accuracy standard similar to, but more lenient than, current regulatory standards. Other metrics of accuracy included the overall compliance proportion; the proportion of extreme outlier readings differing from the reference value by >20%; modified Bland-Altman analysis including average bias, coefficient of variation, and 95% limits of agreement; and proportion of readings with no clinical risk as determined by the Surveillance Error Grid. RESULTS: The different accuracy metrics produced almost identical BGM rankings. Six of the 18 systems met the predetermined accuracy standard in all three studies, 5 systems met it in two studies, and 3 met it in one study. Four BGMs did not meet the accuracy standard in any of the three studies. CONCLUSIONS: Cleared BGMs do not always meet the level of analytical accuracy currently required for regulatory clearance. This information could assist patients, professionals, and payers in choosing products and regulators in evaluating postclearance performance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, comparability of the study by Klonoff et al and our study is limited because Klonoff included BGMS which were cleared by the Food and Drug Administration (FDA) when accuracy criteria were milder than current criteria and applied a non-official accuracy standard which is more lenient than ISO and FDA specifications.29”
From System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015 (2020) · cites this paper as [29]
In the citing paper
“In another accuracy study with the 18 best-selling BGMS in the USA by Klonoff et al,29 12 out of 18 tested BGMS were not meeting accuracy requirements similar to ISO 15197.”
From System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015 (2020) · cites this paper as [29]
In the citing paper
“Most meters meet the accuracy standards established by the International Organization for Standardization”
In the citing paper
“In one analysis, 6 of the top 18 best-selling glucose meters met the accuracy standard (19).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [19]
In the citing paper
“Although measurement quality can come close to or equal that of the glucose monitoring systems used by healthcare professionals, several available SMBG systems still do not meet internationally accepted accuracy standards, such as the International Organization for Standardization 15197 standard.”
From Self-Monitoring of Blood Glucose as an Integral Part in the Management of People with Type 2 Diabetes Mellitus (2022) · cites this paper as [24]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406
Self-citationKlonoff, D. C., Lias, C., Vigersky, R., Clarke, W., Parkes, J. L., Sacks, D. B., Kirkman, M. S., Kovatchev, B., Panel, T. E. G., Aurand, L., et al. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814539589 · Cited by 174
Self-citationComparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127 · cited 1×
“A BGM was considered to have met the standard unless the proportion compliant was in the “clear rejection zone” (7).”
MethodBreton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400309 · Cited by 103
Self-citationHeinemann, L. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0076 · Cited by 69
Performance of Cleared Blood Glucose Monitors
Klonoff, D. C., & Prahalad, P. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815584797 · Cited by 59
Self-citationComputing the Surveillance Error Grid Analysis: Procedure and Examples
Kovatchev, B. P., WAKEMAN, C. A., Breton, M. D., Kost, G. J., Louie, R. F., Tran, N. K., & Klonoff, D. C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814539590 · Cited by 51
Self-citationSchmid, C., Haug, C., Heinemann, L., & Freckmann, G. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0047 · Cited by 34
Blood Glucose Pattern Management in Diabetes: Creating Order from Disorder
Choudhary, P., Genovese, S., & Reach, G. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700618 · Cited by 30
Research works printed but not linked: 1
- Fein, 2015, 2014-15 Economic Report on Retail, Mail, and Specialty Pharmacies
Cited by
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05568-3 · Cited by 378
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
Edelman, S. V., Argento, N. B., Pettus, J., & Hirsch, I. B. (2018) · Diabetes Care · doi:10.2337/dc18-1150 · Cited by 199
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
Management of hypoglycemia in older adults with type 2 diabetes
Freeman, J. S. (2019) · Postgraduate Medicine · doi:10.1080/00325481.2019.1578590 · Cited by 169
New advances in type 1 diabetes
Subramanian, S., Khan, F. N., & Hirsch, I. B. (2024) · BMJ · doi:10.1136/bmj-2023-075681 · Cited by 122
Singh, N. K., Ray, P., Carlin, A. F., Magallanes, C. G., Morgan, S., Laurent, L. C., Aronoff-Spencer, E. S., & Hall, D. A. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113111 · Cited by 106
Yoo, J. H., Choi, M. S., Ahn, J., Park, S. W., Kim, Y., Hur, K. Y., Jin, S., Kim, G., & Kim, J. H. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0499 · Cited by 107
Evolution of Diabetes Technology
Dovč, K., & Battelino, T. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.009 · Cited by 132
A Pragmatic Approach to Inpatient Diabetes Management during the COVID-19 Pandemic
Korytkowski, M. T., Antinori-Lent, K., Drincic, A., Hirsch, I. B., McDonnell, M. E., Rushakoff, R. J., & Muniyappa, R. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa342 · Cited by 94
Longo, R. R., Elias, H., Khan, M., & Seley, J. J. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211008446 · Cited by 89
A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials
Spanakis, E. K., Cook, C. B., Kulasa, K. M., Aloi, J., Bally, L., Davis, G. M., Dungan, K. M., Galindo, R. J., Mendez, C. E., Pasquel, F. J., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231191104 · Cited by 92
Self-citationZaharieva, D. P., MCGAUGH, S. M., Pooni, R., Vienneau, T. E., Ly, T. T., & Riddell, M. C. (2019) · Diabetes Care · doi:10.2337/dc18-2204 · Cited by 89
Lu, H. Y., Ding, X., Hirst, J. E., Yang, Y., Yang, J., Mackillop, L. H., & Clifton, D. A. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3242261 · Cited by 77
Time in range centered diabetes care
Dovč, K., & Battelino, T. (2021) · Clinical Pediatric Endocrinology · doi:10.1297/cpe.30.1 · Cited by 70
Pleus, S., Baumstark, A., Jendrike, N., Mende, J., Link, M., Zschornack, E., Haug, C., & Freckmann, G. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001067 · Cited by 63
Monitoring of Pediatric Type 1 Diabetes
Marks, B. E., & Wolfsdorf, J. I. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00128 · Cited by 71
Forlenza, G. P., Kushner, T., Messer, L. H., Wadwa, R. P., & Sankaranarayanan, S. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0401 · Cited by 63
Pleus, S., Freckmann, G., Schauer, S., Heinemann, L., Ziegler, R., Ji, L., Mohan, V., Calliari, L. E., & Hinzmann, R. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01254-8 · Cited by 55
“[24], only 33% of the evaluated systems met the accuracy requirements of the International Organization for Standardization (ISO) 15197:2013 standard, whereas in a study by Pleus et al.”
BackgroundMethodChamberlain, J. J., Doyle-Delgado, K., Peterson, L., & SKOLNIK, N. (2019) · Annals of Internal Medicine · doi:10.7326/m19-1638 · Cited by 60
The Diabetes Technology Society Error Grid and Trend Accuracy Matrix for Glucose Monitors
Klonoff, D. C., Freckmann, G., Pleus, S., Kovatchev, B. P., Kerr, D. E., Tse, C., Li, C., Agus, M. S. D., Dungan, K. M., Hagerf, B. V., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241275701 · Cited by 57
Self-citationRecent advances in diabetes treatments and their perioperative implications
Kuzulugil, D., Papeix, G., Luu, J., & Kerridge, R. K. (2019) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000735 · Cited by 52
Diabetes Technology Use in Adults with Type 1 and Type 2 Diabetes
Kravarusic, J., & Aleppo, G. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.006 · Cited by 51
Performing nutrition assessment remotely via telehealth
Mauldin, K., Gieng, J., Saarony, D., & Hu, C. (2021) · Nutrition in Clinical Practice · doi:10.1002/ncp.10682 · Cited by 47
The Impact of Recent Developments in Electrochemical POC Sensor for Blood Sugar Care
Li, W., Luo, W., Li, M., Chen, L., Chen, L., Guan, H., & Yu, M. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.723186 · Cited by 47
Loh, H. H., Lim, L., Loh, H. S., & Yee, A. H. A. (2019) · Journal of Diabetes Investigation · doi:10.1111/jdi.13054 · Cited by 39
Sheen, Y., Huang, C., Huang, S., Huang, M.-D., Lin, C., Lee, I., Lin, S., & Sheu, W. H. (2019) · Endocrine Practice · doi:10.4158/ep-2019-0264 · Cited by 35
Effects of a HIIT Protocol on Cardiovascular Risk Factors in a Type 1 Diabetes Mellitus Population
Alarcón-Gómez, J., Calatayud, J., Chulvi‐Medrano, I., & Martin-Rivera, F. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18031262 · Cited by 29
Chen, J., Sun, X., Wang, Y., Gao, Z., & Zheng, B. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133712 · Cited by 27
Glavas, M. M., Lee, A. Y., Miao, I., Yang, F., Mojibian, M., O’Dwyer, S. M., & Kieffer, T. J. (2021) · Diabetes · doi:10.2337/db21-0310 · Cited by 26
Selecting Mobile Health Technologies for Electronic Health Record Integration: Case Study
Shaw, R. J., Stroo, M., Fiander, C., & McMillan, K. (2020) · Journal of Medical Internet Research · doi:10.2196/23314 · Cited by 25
Diabetes technology in people with diabetes and advanced chronic kidney disease
Galindo, R. J., Soliman, D., Cherñavvsky, D. R., & Rhee, C. M. (2024) · Diabetologia · doi:10.1007/s00125-024-06244-y · Cited by 25
One Drop App With an Activity Tracker for Adults With Type 1 Diabetes: Randomized Controlled Trial
Osborn, C. Y., Hirsch, A., Sears, L. E., Heyman, M., Raymond, J. K., Huddleston, B., & Dachis, J. (2020) · JMIR mhealth and uhealth · doi:10.2196/16745 · Cited by 26
Katz, L. B., Stewart, L. S., Guthrie, B., & Cameron, H. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819867396 · Cited by 23
Philis‐Tsimikas, A., STRATTON, I. M., Troelsen, L. N., Bak, B. A., & Leiter, L. A. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819841585 · Cited by 22
Managing discordance between HbA 1c and glucose management indicator
Lenters‐Westra, E., Fokkert, M. J., Kilpatrick, E. S., Schleicher, E. D., Pilla, S. J., English, E., & van Dijk, P. R. (2025) · Diabetic Medicine · doi:10.1111/dme.70023 · Cited by 21
Ukpe, M. P., & Ezeanuka, A. C. (2025) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2025.110911 · Cited by 18
Longo, R. R., & Joshi, R. (2022) · Diabetes Spectrum · doi:10.2337/dsi22-0009 · Cited by 20
How conclusive is the CONCLUDE trial?
Prato, S. D. (2020) · Diabetologia · doi:10.1007/s00125-020-05086-8 · Cited by 16
Potential contributions of the methodology to the variability of glycaemic index of foods
Flavel, M., Jois, M., & Kitchen, B. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i2.108 · Cited by 18
Huang, W., Li, S., Lu, J., Shen, Y., Wang, Y., Wang, Y., Feng, K., Huang, X., Zou, Y., Hu, L., et al. (2022) · Endocrine · doi:10.1007/s12020-022-03216-3 · Cited by 16
Holt, R. I. G., DeVries, J. H., Fischl, A. H., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, É., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05600-6 · Cited by 19
Making sense of glucose sensors in end-stage kidney disease: A review
Williams, M. E., Steenkamp, D., & Wolpert, H. A. (2022) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2022.1025328 · Cited by 14
Sheen, Y., Huang, C., Huang, S., Lin, C., Lee, I., & Sheu, W. H. (2021) · Journal of Diabetes Investigation · doi:10.1111/jdi.13500 · Cited by 14
Freckmann, G., Baumstark, A., Jendrike, N., Mende, J., Schauer, S., Link, M., Pleus, S., & Haug, C. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820948873 · Cited by 12
Pfützner, A., Demircik, F., Kirsch, V., Pfützner, J. W., Strobl, S., Hanna, M., Spatz, J., & Pfützner, A. H. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819841353 · Cited by 11
Accuracy and User Performance of a New Blood Glucose Monitoring System
Klaff, L. J., Shelat, P., Zondorak, D., Wayland-Smith, A., Vernes, P., & Richardson, J. M. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820974348 · Cited by 12
Pleus, S., Jendrike, N. R. M., Baumstark, A., Mende, J., Wehrstedt, S., Haug, C., & Freckmann, G. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01517-y · Cited by 11
Evidence-Based Diagnosis: An Introduction to Clinical Epidemiology
Newman, T. B., & Kohn, M. A. (2020) · Cited by 10
Self-citationSasaki, Y., Ohshiro, K., Kato, M., Haba, D., Nakagami, G., & Minami, T. (2024) · ChemElectroChem · doi:10.1002/celc.202400292 · Cited by 12
Eichenlaub, M., Pleus, S., Shaginian, R. M., Richardson, J. M., Pardo, S. A., Stuhr, A., & Freckmann, G. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221080916 · Cited by 9
Sasaki, Y., & Minami, T. (2025) · Analytical Sciences · doi:10.1007/s44211-025-00750-8 · Cited by 8
Elabd, S. S., & Poole, R. (2023) · Practical Diabetes · doi:10.1002/pdi.2479 · Cited by 8
Continuous glucose monitoring in para cyclists: An observational study
Weijer, V., van der Werf, R., van der Haijden, M., Jeukendrup, A. E., van Loon, L. J. C., & van Dijk, J. (2024) · European Journal of Sport Science · doi:10.1002/ejsc.12220 · Cited by 8
Immanuel, J., Kongbrailatpam, T., Rajagopal, R., & Simmons, D. S. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16209 · Cited by 8
Demircik, F., Kirsch, V., Ramljak, S., Vogg, M., Pfützner, A. H., & Pfützner, A. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819841357 · Cited by 8
Tanaka, K., Higuchi, R., Mizusawa, K., Nakamura, T., & Nakajima, K. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i7.1131 · Cited by 9
Pleus, S., Jendrike, N. R. M., Baumstark, A., Mende, J., Haug, C., & Freckmann, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818804837 · Cited by 8
Pleus, S., Heinemann, L., Freckmann, G., Nauck, M. A., Tytko, A., Kaiser, P., & Petersmann, A. (2021) · Diabetologie und Stoffwechsel · doi:10.1055/a-1528-8248 · Cited by 8
Klonoff, D. C. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819843398 · Cited by 8
Self-citationNia, H. S., Mokhtari, H., Osborne, J. W., Shafaei, S., & Soltanzade, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-28009-2 · Cited by 7
Mader, J. K., Baumstark, A., Tüting, J., Sokol, G., Schuebel, R., Tong, Y., Roetschke, J., & Slingerland, R. J. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01665-9 · Cited by 8
Kim, H. N., & Yoon, S. (2021) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.24055 · Cited by 7
Dyess, R. J., McKay, T. E., Feygin, Y. B., Wintergerst, K. A., & Thrasher, B. J. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221120433 · Cited by 7
Optimizing Diabetes Care With the Standardized Continuous Glucose Monitoring Report
Chun, J. H., & O’Neill, M. S. (2020) · Clinical Diabetes · doi:10.2337/cd19-0066 · Cited by 7
A Pilot Trial to Evaluate the Accuracy of a Novel Non-Invasive Glucose Meter
Schwarz, Y., Konvalina, N., & Tirosh, A. (2021) · Sensors · doi:10.3390/s21206704 · Cited by 7
Reducing Glucose Meter Adverse Events by Using Reliability Growth With the FDA MAUDE Database
Krouwer, J. S. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818814457 · Cited by 7
Simulating Realistic Continuous Glucose Monitor Time Series By Data Augmentation
Gomez, L., Toye, A. A., Hum, R. S., & Kleinberg, S. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231181138 · Cited by 7
Zelnick, L. R., Trikudanathan, S., Hall, Y. N., Ayers, E., Anderson, L., Ashford, N. K., Jones, E., Hoofnagle, A. N., de Boer, I. H., & Hirsch, I. B. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251368934 · Cited by 7
Bellini, A., Nicolò, A., Rocchi, J. E., Bazzucchi, I., & Sacchetti, M. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20010253 · Cited by 6
Nonadjunctive Use of Continuous Glucose Monitoring: The End of Fingersticks?
Beck, R. W., Brown, S. A., Lum, J. W., & Kovatchev, B. P. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0387 · Cited by 6
Self-citationBotelho, M. S., Galendi, J. S. C., Novo, M. A. F. M., & Nogueira, V. D. S. N. (2025) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-025-01935-x · Cited by 5
Jendrike, N. R. M., Baumstark, A., Pleus, S., Mende, J., Haug, C., & Freckmann, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818821105 · Cited by 5
Setford, S. J., Phillips, S., & Grady, M. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819826968 · Cited by 5
The pharmacist’s role in continuous glucose monitoring
Isaacs, D. M. (2020) · Pharmacy Today · doi:10.1016/j.ptdy.2020.04.014 · Cited by 5
Yoshino, S., Yamada, E., Okada, S., Nakajima, Y., Shibusawa, R., Uehara, R., Matsumoto, S., Horiguchi, K., Ishida, E., Saito, T., et al. (2020) · Endocrine Journal · doi:10.1507/endocrj.ej19-0488 · Cited by 7
Non-Invasive Blood Glucose Measurement Using Laser Technology (NIBGM)
Tashtoush, A. (2021) · International Journal of Computing and Digital Systems · doi:10.12785/ijcds/100130 · Cited by 5
Choi, S., Choi, S. J., Kim, J. K., Lee, Y.-W., & Lee, Y. K. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.43.5.515 · Cited by 5
Impact of hematocrit levels on the accuracy of specific blood glucose meters: A hospital‐based study
Pham, H. N., Pham, P. N. H., Phan, H. T., Cao, L. T., Thoi, H. T. T., Thanh, T. D., & Truong, T. T. A. (2024) · Journal of Diabetes Investigation · doi:10.1111/jdi.14276 · Cited by 5
Pleus, S., Baumstark, A., Schauer, S., Kölle, J., Jendrike, N. R. M., Mende, J., Haug, C., & Freckmann, G. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221141926 · Cited by 4
Luppa, P. B., Zeller, M., Pieper, M., Kaiser, P., Weiss, N., Vierbaum, L., & Freckmann, G. (2024) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2024.1371426 · Cited by 4
Dahya, K., Kuiper, H. C., Kingsley, S. W., Danilenko, U., & Vesper, H. W. (2025) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2025.04.005 · Cited by 4
Accuracy of Glucose Meter Among Adults in a Semi-urban Area in Kathmandu, Nepal
Pokhrel, A., Silvanus, V., Pokhrel, B. R., Baral, B. K., Khanal, M. P., Gyawali, P., Pokhrel, L., & Regmi, D. (2019) · Journal of Nepal Medical Association · doi:10.31729/jnma.4247 · Cited by 6
Villa-Tamayo, M. F., Builes-Montaño, C. E., Rincón, A. R., Carvajal, J. A., & Rivadeneira, P. S. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221133405 · Cited by 4
El-Moghazy, A. Y., Amaly, N., Sun, G. Z., & Nitin, N. (2022) · Talanta · doi:10.1016/j.talanta.2022.124117 · Cited by 4
Song, D., Hurley, J. C., & Lia, M. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17217725 · Cited by 5
Gessell, A. J., & Small, G. W. (2025) · Analytical Letters · doi:10.1080/00032719.2025.2578671 · Cited by 3
Integrating diabetes technologies with team-based primary care for type 2 diabetes: A pilot trial
O’Brien, M. J., Stephen, J. J., Norton, K. L., Meehan, T. P., Vojta, D. D., & Ackermann, R. T. (2021) · Primary care diabetes · doi:10.1016/j.pcd.2021.07.010 · Cited by 3
A Comprehensive Review on the Accuracy Determination Methods for Glucose Meters
Kesavadev, J., Saboo, B., Gupta, A. S., Sreelakshmi, R., & Krishnan, G. (2023) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_1_24 · Cited by 3
Glucometer versus analyzer: comparable results with negligible clinical risk
Gümüş, A., Coşkun, C., Uçar, K. T., Erdin, İ., Tek, S., Evran, B., Çat, A., & Zengi, O. (2025) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2025.2456917 · Cited by 3
Thorpe, G. H. G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818799365 · Cited by 4
Updates and advances in technology for diabetes self-management
Bzowyckyj, A. S. (2019) · Pharmacy Today · doi:10.1016/j.ptdy.2019.04.024 · Cited by 3
Metadata
- Authors
- Klonoff, D. C., Parkes, J. L., Kovatchev, B. P., Kerr, D., Bevier, W. C., Brazg, R. L., Christiansen, M., Bailey, T. S., Nichols, J. H., & Kohn, M. A.
- Affiliations
- Mills-Peninsula Medical Center, Diabetes Research Institute, San Mateo, CA
- Joan Lee Parkes Consulting, Inc., Bristol, IN
- University of Virginia (US)
- Sansum Diabetes Research Institute (US)
- Rainier Clinical Research Center (US)
- Diablo Clinical Research (US)
- AMCR Institute (US)
- Vanderbilt University (US)
- University of California, San Francisco (US)
- Corresponding author
- Klonoff, David C.
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2018-06-13
- Volume
- 41
- Issue
- 8
- Pages
- 1681-1688
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2808448482
- Cited by
- 144
- References
- 12
- Citations by year
- 2026: 9 · 2025: 13 · 2024: 14 · 2023: 12 · 2022: 15 · 2021: 24 · 2020: 26 · 2019: 25 · 2018: 6
- FWCI
- 16.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Abbott Diabetes Care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Keywords
- blood glucose meters, point-of-care glucose testing, accuracy, regulatory approval, capillary blood glucose, Bland-Altman analysis, consumer product evaluation, diabetes self-monitoring
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Blood Glucose, Commerce, Diabetes Mellitus, Double-Blind Method, Equipment and Supplies, Female, Hematocrit, Humans, Male, Middle Aged, Patient Compliance, Prediabetic State, Reference Values, United States, United States Food and Drug Administration, Blood Glucose Self-Monitoring, Reproducibility of Results, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.