Cited by 31Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

Continuous glucose monitoring in adults with type 1 diabetes with 35 years duration from the DCCT/EDIC study

Open access
Gubitosi-Klug, Rose A., Braffett, Barbara H., Bebu, Ionut, Johnson, Mary L., Farrell, Kaleigh, Kenny, David, Trapani, Victoria R., Meadema-Mayer, Lynne +5 more·2022·Diabetes Care

Published version of a preprint

Abstract

Objective We evaluated blinded continuous glucose monitoring (CGM) profiles in a subset of adults with type 1 diabetes from the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) study to characterize the frequency of glycemic excursions and contributing factors. Research design and methods CGM-derived metrics were compared for daytime and nighttime periods using blinded CGM for a minimum of 6.5 days (average 11.9 days) and correlated with HbA1c levels, routine use of diabetes devices, and other characteristics in 765 participants. Results Participants were 58.9 ± 6.5 years of age with diabetes duration 36.8 ± 4.9 years and HbA1c 7.8 ± 1.2%; 58% used insulin pumps, and 27% used personal, unblinded CGM. Compared with daytime, nighttime mean sensor glucose was lower, percent time in range 70-180 mg/dL (TIR) was similar, and hypoglycemia was more common. Over the entire recording period, only 9% of the 765 participants achieved >70% TIR and only 28% achieved Conclusions In adults with long-standing type 1 diabetes, short-term blinded CGM profiles revealed frequent clinically significant hypoglycemia (<54 mg/dL) during the night and more time in hyperglycemia during the day. The small subset of participants using routine CGM and insulin pumps had fewer hypoglycemic and hyperglycemic excursions and lower HbA1c levels. Thus, strategies to lower meal-stimulated hyperglycemia during the day and prevent hypoglycemia at night a…

Integrity signals

Registry

Crossref · 10.2337/dc21-0629

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Observational data from the DCCT/EDIC study indicate that among older adults (mean age 58 years) with long-standing type 1 diabetes, routine continuous glucose monitoring and insulin pump use was associated with fewer hypoglycemic events and hyperglycemic excursions and lower A1C levels.

    “These and other short-term trials are supported by observational data from the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) study indicating that among older adults (mean age 58 years) with long-standing type 1 diabetes, routine CGM and insulin pump use was associated with fewer hypoglycemic events and hyperglycemic excursions and”
  • Observational data from the DCCT/EDIC study indicate that among older adults (mean age 58 years) with long-standing type 1 diabetes, routine CGM and insulin pump use was associated with fewer hypoglycemic events and hyperglycemic excursions and lower A1C levels.

    “These and other short-term trials are supported by observational data from the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) study indicating that among older adults (mean age 58 years) with long-standing type 1 diabetes, routine CGM and insulin pump use was associated with fewer hypoglycemic events and hyperglycemic excursions and”

    From 13. Older Adults: Standards of Care in Diabetes—2025 (2025) · cites this paper as [43]

  • CGM devices have been shown to be effective at improving glycemic management.

    “Continuous glucose monitoring (CGM) devices have been shown to be effective at improving glycemic management and acceptable to people of all age-groups, including older individuals with type 1 diabetes (44–48) or insulin-requiring type 2 diabetes (49,50).”

    From 13. Older Adults: Standards of Care in Diabetes—2026 (2026) · cites this paper as [47]

  • CGM devices are acceptable to people of all age-groups, including older individuals with type 1 diabetes or insulin-requiring type 2 diabetes.

    “Continuous glucose monitoring (CGM) devices have been shown to be effective at improving glycemic management and acceptable to people of all age-groups, including older individuals with type 1 diabetes (44–48) or insulin-requiring type 2 diabetes (49,50).”

    From 13. Older Adults: Standards of Care in Diabetes—2026 (2026) · cites this paper as [47]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Gubitosi-Klug, R. A., Braffett, B. H., Bebu, I., Johnson, M. L., Farrell, K., Kenny, D., Trapani, V. R., Meadema-Mayer, L., Soliman, E. Z., Pop-Busui, R., Lachin, J. M., Bergenstal, R. M., & Tamborlane, W. V.
Affiliations
  • Rainbow Babies and Children’s Hospital, Case Western Reserve University, Cleveland, OH
  • George Washington University (US)
  • International Diabetes Center, Minneapolis, MN
  • Rainbow Babies & Children's Hospital (US)
  • Wake Forest University Health Sciences (US)
  • University of Michigan, Ann Arbor, MI
  • Yale University (US)
Corresponding author
Braffett, Barbara H.
Venue
Diabetes Care
Published
2022-01-25
Volume
45
Issue
3
Pages
659-665
ISSN
0149-5992 (ISSN-L)
OpenAlex
W4207049476
Cited by
31
References
10
Citations by year
2026: 2 · 2025: 9 · 2024: 8 · 2023: 6 · 2022: 6
FWCI
5.37
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5u01dk094157-13, UL1TR001863)
  • National Institute of Diabetes and Digestive and Kidney Diseases (U01DK094176, U01-DK094157, DP3DK106890, P30DK020572, P30DK045735)
  • National Center for Advancing Translational Sciences
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, continuous glucose monitoring, glycemic excursions, hypoglycemia, hyperglycemia, time in range, HbA1c, insulin pump, long-standing diabetes, adults
MeSH terms
Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Glucose, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review