Glucose Disposal is Not Proportional to Plasma Glucose Level in Man
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Metabolic clearance rate (MCR) of glucose has been defined as the rate of glucose utilization divided by the glucose concentration. This model of glucose transport has been widely used as a measure of hormonally regulated glucose disposal, on the assumption that glucose disposal rate is proportional to glucose concentration. To test this assumption, the relationship between glucose concentration and disposal rate was studied in man during infusion of somatostatin ± exogenous insulin to achieve fixed plasma insulin levels of 1,18, and 46 μU/ml on separate days. When glucose concentration was increased to more than twice basal fasting levels, the glucose disposal rate increased significantly at all three insulin levels. However, the increase was not proportional to the rise in glucose concentration, and MCR fell by 38%, 16%, and 11% at the low, medium, and high insulin levels, respectively. These results are explained by an alternative model of glucose transport in which insulin-independent tissues such as brain have a relatively fixed glucose uptake, while other tissues have glucose transport systems which take up glucose at a rate proportional to its plasma concentration. We conclude that MCR of glucose is not a good measure of hormonally regulated glucose disposal because it is partially dependent on the glucose concentration, particularly at low insulin levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rizza, R., Verdonk, C., Miles, J., Service, F. J., & Gerich, J. (1979) · Journal of Clinical Investigation · doi:10.1172/jci109404 · Cited by 68
Cited by
Lillioja, S., Mott, D. M., Spraul, M., Ferraro, R., Foley, J. E., Ravussin, E., Knowler, W. C., Bennett, P. H., & Bogardus, C. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292703 · Cited by 1,508
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Assessment of Insulin Sensitivity in Vivo*
Bergman, R. N., Finegood, D. T., & Ader, M. (1985) · Endocrine Reviews · doi:10.1210/edrv-6-1-45 · Cited by 1,066
Impaired Glucose Tolerance as a Disorder of Insulin Action
Lillioja, S., Mott, D. M., Howard, B. V., Bennett, P. H., Yki-Järvinen, H., Freymond, D., Nyomba, B. L., Zurlo, F., Swinburn, B., & Bogardus, C. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181901 · Cited by 578
DeFronzo, R. A., Ferrannini, E., & Simonson, D. C. (1989) · Metabolism · doi:10.1016/0026-0495(89)90129-7 · Cited by 515
Partitioning glucose distribution/transport, disposal, and endogenous production during IVGTT
Hovorka, R., Shojaee-Moradie, F., Carroll, P. V., Chassin, L. J., Gowrie, I. J., Jackson, N. C., Tudor, R. S., Umpleby, A. M., & Jones, R. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00304.2001 · Cited by 393
“dQ2 t dt x1 t Q1 t k12 x2 t Q2 t Q2 0 Q1 0 x1 0 x2 0 k12 (8)”
BackgroundResultA model of β-cell mass, insulin, and glucose kinetics: pathways to diabetes
TOPP, B., PROMISLOW, K., DEVRIES, G., MIURA, R. M., & FINEGOOD, D. T. (2000) · Journal of Theoretical Biology · doi:10.1006/jtbi.2000.2150 · Cited by 330
Insulin resistance associated with lower rates of weight gain in Pima Indians.
Swinburn, B. A., Nyomba, B. L., Saad, M. F., Zurlo, F., Raz, I., Knowler, W. C., Lillioja, S., Bogardus, C., & Ravussin, E. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115274 · Cited by 322
The disposal of an oral glucose load in patients with non-insulin-dependent diabetes
Ferrannini, E., Simonson, D. C., Katz, L. D., Reichard, G., Bevilacqua, S., Barrett, E. J., Olsson, M., & DeFronzo, R. A. (1988) · Metabolism · doi:10.1016/0026-0495(88)90033-9 · Cited by 305
Insulin resistance in noninsulin-dependent diabetes mellitus
Reaven, G. M. (1983) · The American Journal of Medicine · doi:10.1016/0002-9343(83)90650-2 · Cited by 154
Koska, J., Stefan, N., Permana, P. A., Weyer, C., Sonoda, M., Bogardus, C., Smith, S. R., Joanisse, D. R., Funahashi, T., Krakoff, J., et al. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/87.2.295 · Cited by 129
“Individual variation in plasma glucose and insulin concentrations during the clamp was taken into account in the calculation of the insulin-mediated glucose disposal (17, 19).”
BackgroundKrudys, K. M., Dodds, M. G., Nissen, S. M., & Vicini, P. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00058.2004 · Cited by 30
“where q1 and q2 are glucose tracer masses (mg/kg for a stable-label IVGTT) in the accessible and slowly equilibrating compartments, respectively, x(t) kcI (t) is insulin action (min (1)) with I (t) denoting the concentration of insulin in a compartment remote from plasma ( U/ml), g(t) is plasma hot glucose concentrati…”
Background
Metadata
- Authors
- Best, J. D., Taborsky, G. J., Halter, J. B., & Porte, D.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1981-10-01
- Volume
- 30
- Issue
- 10
- Pages
- 847-850
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W1981737637
- Cited by
- 156
- References
- 1
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.