Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 277

The DOI matches its Crossref record.

Hypothalamic glucose sensor: similarities to and differences from pancreatic beta-cell mechanisms.

Yang, X J, Kow, L M, Funabashi, T, Mobbs, C V·1999·Diabetes

Abstract

Glucose-responsive neurons in the ventromedial hypothalamus (VMH) are stimulated when glucose increases from 5 to 20 mmol/l and are thought to play an essential role in regulating metabolism. The present studies examined the role of glucose metabolism in the mechanism by which glucose-responsive neurons sense glucose. The pancreatic, but not hepatic, form of glucokinase was expressed in the VMH, but not cerebral cortex, of adult rats. In brain slice preparations, the transition from 5 to 20 mmol/l glucose stimulated approximately 17% of the neurons (as determined by single-cell extracellular recording) from VMH but none in cortex. In contrast, most cells in both VMH and cortex were silent below 1 mmol/l and active at 5 mmol/l glucose. Glucosamine, 2-deoxyglucose, phloridzin, and iodoacetic acid blocked the activation of glucose-responsive neurons by the transition from 5 to 20 mmol/l glucose. Adding 15 mmol/l mannose, galactose, glyceraldehyde, glycerol, and lactate to 5 mmol/l glucose stimulated glucose-responsive neurons. In contrast, adding 15 mmol/l pyruvate to 5 mmol/l glucose failed to activate glucose-responsive neurons, although pyruvate added to 0 mmol/l glucose permitted neurons to maintain activity. Tolbutamide activated glucose-responsive neurons; however, diazoxide only blocked the effect of glucose in a minority of neurons. These data suggest that glucose-responsive neurons sense glucose through glycolysis using a mechanism similar to the mechanism of pancreatic beta-cells, except that glucose-responsive neurons are stimulated by glycerol and lactate, and diazoxide does not generally block the effect of glucose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diabetes.48.9.1763

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 277

Metadata

Authors
Yang, X. J., Kow, L. M., Funabashi, T., & Mobbs, C. V.
Venue
Diabetes
Published
1999-09-01
Volume
48
Issue
9
Pages
1763-1772
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W1968750290
Cited by
277
References
0
FWCI
3.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hypothalamic glucose sensor: similarities to and differences from pancreatic beta-cell mechanisms. https://app.cochat.ai/papers/10.2337/diabetes.48.9.1763
The paper
Yang, X. J., Kow, L. M., Funabashi, T., & Mobbs, C. V. (1999). Hypothalamic glucose sensor: similarities to and differences from pancreatic beta-cell mechanisms. Diabetes. https://doi.org/10.2337/diabetes.48.9.1763

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.