Assessing the Predictive Accuracy of QUICKI as a Surrogate Index for Insulin Sensitivity Using a Calibration Model
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
The quantitative insulin-sensitivity check index (QUICKI) has an excellent linear correlation with the glucose clamp index of insulin sensitivity (SIClamp) that is better than that of many other surrogate indexes. However, correlation between a surrogate and reference standard may improve as variability between subjects in a cohort increases (i.e., with an increased range of values). Correlation may be excellent even when prediction of reference values by the surrogate is poor. Thus, it is important to evaluate the ability of QUICKI to accurately predict insulin sensitivity as determined by the reference glucose clamp method. In the present study, we used a calibration model to compare the ability of QUICKI and other simple surrogates to predict SIClamp. Predictive accuracy was evaluated by both root mean squared error of prediction as well as a more robust leave-one-out cross-validation–type root mean squared error of prediction (CVPE). Based on data from 116 glucose clamps obtained from nonobese, obese, type 2 diabetic, and hypertensive subjects, we found that QUICKI and log (homeostasis model assessment [HOMA]) were both excellent at predicting SIClamp (CVPE = 1.45 and 1.51, respectively) and significantly better than HOMA, 1/HOMA, and fasting insulin (CVPE = 3.17, P < 0.001; 1.67, P < 0.02; and 2.85, P < 0.001, respectively). QUICKI and log(HOMA) also had the narrowest distribution of residuals (measured SIClamp − predicted SIClamp). In a subset of subjects (n = 78) who also underwent a frequently sampled intravenous glucose tolerance test with minimal model analysis, QUICKI was significantly better than the minimal model index of insulin sensitivity (SIMM) at predicting SIClamp (CVPE = 1.54 vs. 1.98, P = 0.001). We conclude that QUICKI and log(HOMA) are among the most accurate surrogate indexes for determining insulin sensitivity in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
Matthews, D. R., Hosker, J. P., Rudenski, A. S., Naylor, B. A., Treacher, D. F., & Turner, R. C. (1985) · Diabetologia · doi:10.1007/bf00280883 · Cited by 31,502
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425
Grundy, S. M., Brewer, H. B., Cleeman, J. I., Smith, S. C., & Lenfant, C. (2004) · Circulation · doi:10.1161/01.cir.0000111245.75752.c6 · Cited by 5,982
Matsuda, M., & DeFronzo, R. A. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1462 · Cited by 5,621
Katz, A., Nambi, S. S., Mather, K., Baron, A. D., Follmann, D. A., Sullivan, G., & Quon, M. J. (2000) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.85.7.6661 · Cited by 3,931 · cited 9×
“Because previous studies demonstrated a linear relationship between SIClamp and QUICKI or SIMM (19,21,43), we chose a standard calibration model to evaluate the predictive accuracy of various simple surrogate indexes of insulin sensitivity.”
BackgroundMethodResultInfluentialSelf-citationBonora, E., Targher, G., Alberiche, M., Bonadonna, R. C., Saggiani, F., Zenere, M. B., Monauni, T., & Muggeo, M. (2000) · Diabetes Care · doi:10.2337/diacare.23.1.57 · Cited by 2,456
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2004) · Diabetes Care · doi:10.2337/diacare.27.2007.s5 · Cited by 1,666
Toward Physiological Understanding of Glucose Tolerance: Minimal-Model Approach
Bergman, R. N. (1989) · Diabetes · doi:10.2337/diab.38.12.1512 · Cited by 1,001
Bergman, R. N., Prager, R., Volund, A., & Olefsky, J. M. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112886 · Cited by 772 · cited 1×
“Because previous studies demonstrated a linear relationship between SIClamp and QUICKI or SIMM (19,21,43), we chose a standard calibration model to evaluate the predictive accuracy of various simple surrogate indexes of insulin sensitivity.”
MethodAscaso, J. F., Pardo, S., Real, J. T., Lorente, R. I., Priego, A., & Carmena, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.12.3320 · Cited by 490
Katsuki, A., Sumida, Y., Gabazza, E. C., Murashima, S., Furuta, M., Araki-Sasaki, R., Hori, Y., Yano, Y., & Adachi, Y. (2001) · Diabetes Care · doi:10.2337/diacare.24.2.362 · Cited by 431
Mather, K. J., Hunt, A. E., Steinberg, H. O., Paradisi, G., Hook, G., Katz, A., Quon, M. J., & Baron, A. D. (2001) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.86.11.7880 · Cited by 363 · cited 2×
“In addition, test characteristics of QUICKI including coefficient of variation and discriminant ratio are significantly better than other simple surrogate indexes and comparable with those of the glucose clamp (20).”
ResultSelf-citationYeckel, C. W., Weiss, R., Dziura, J., Taksali, S. E., Dufour, S., Burgert, T. S., Tamborlane, W. V., & Caprio, S. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031503 · Cited by 352
Obesity, Insulin Resistance, and Cardiovascular Disease
Reaven, G. (2004) · Recent Progress in Hormone Research · doi:10.1210/rp.59.1.207 · Cited by 348
Measurement, Regression, and Calibration
Gleser, L. J., & Brown, P. J. (1996) · Technometrics · doi:10.2307/1268905 · Cited by 308
PPARγ and the Treatment of Insulin Resistance
OLEFSKY, J., & SALTIEL, A. (2000) · Trends in Endocrinology and Metabolism · doi:10.1016/s1043-2760(00)00306-4 · Cited by 279
McFarlane, S. I., Kumar, A., & Sowers, J. R. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00432-6 · Cited by 245
Uwaifo, G. I., Fallon, E. M., Chin, J., Elberg, J., Parikh, S. J., & Yanovski, J. A. (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2081 · Cited by 228
Clinically Useful Estimates of Insulin Sensitivity During Pregnancy
Kirwan, J. P., Huston-Presley, L., Kalhan, S. C., & Catalano, P. M. (2001) · Diabetes Care · doi:10.2337/diacare.24.9.1602 · Cited by 218
Lilly lecture 1989. Toward physiological understanding of glucose tolerance. Minimal-model approach
Bergman, R. N. (1989) · Diabetes · doi:10.2337/diabetes.38.12.1512 · Cited by 215
Rosiglitazone Improves Insulin Sensitivity and Lowers Blood Pressure in Hypertensive Patients
Raji, A., Seely, E. W., Bekins, S. A., Williams, G. H., & Simonson, D. C. (2003) · Diabetes Care · doi:10.2337/diacare.26.1.172 · Cited by 215
Yokoyama, H., Emoto, M., Fujiwara, S., Motoyama, K., Morioka, T., Komatsu, M., Tahara, H., Shoji, T., Okuno, Y., & Nishizawa, Y. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2426 · Cited by 215
Prediction of Type 2 Diabetes Using Simple Measures of Insulin Resistance
Hanley, A. J. G., Williams, K., Gonzalez, C., D’Agostino, R. B., Wagenknecht, L. E., Stern, M. P., & Haffner, S. M. (2003) · Diabetes · doi:10.2337/diabetes.52.2.463 · Cited by 201
QUICKI is a useful index of insulin sensitivity in subjects with hypertension
Chen, H., Sullivan, G., Yue, L. Q., Katz, A., & Quon, M. J. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00330.2002 · Cited by 159
Self-citationRabasa-Lhoret, R., Bastard, J.-P., Jan, V., Ducluzeau, P.-H., Andreelli, F., Guebre, F., Bruzeau, J., Louche-Pellissier, C., MaÎtrepierre, C., Peyrat, J., et al. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-030316 · Cited by 149
Effects of Exercise and Weight Loss on Cardiac Risk Factors Associated With Syndrome X
Watkins, L. L., Sherwood, A., Feinglos, M., Hinderliter, A., Babyak, M., Gullette, E., Waugh, R., & Blumenthal, J. A. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.16.1889 · Cited by 134
Novel Insulin Sensitivity Index Derived from Oral Glucose Tolerance Test
Soonthornpun, S., Setasuban, W., Thamprasit, A., Chayanunnukul, W., Rattarasarn, C., & Geater, A. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021127 · Cited by 119
Correlation between the glucose clamp technique and the homeostasis model assessment in hypertension
Lansang, M. (2001) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)01229-2 · Cited by 116
Škrha, J., Haas, T., Šindelka, G., Prázný, M., Widimský, J., Cibula, D., & Svačina, Š. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-030024 · Cited by 108
Quon, M. J., Cochran, C., Taylor, S. I., & Eastman, R. C. (1994) · Diabetes · doi:10.2337/diab.43.7.890 · Cited by 96
Self-citationYokoyama, H., Emoto, M., Fujiwara, S., Motoyama, K., Morioka, T., Komatsu, M., Tahara, H., Koyama, H., Shoji, T., Inaba, M., et al. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031374 · Cited by 94
Rajala, U., Laakso, M., Päivänsalo, M. J., Pelkonen, O., Suramo, I., & Keinanen-Kiukaanniemi, S. M. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-020703 · Cited by 76
Cerivastatin Improves Insulin Sensitivity and Insulin Secretion in Early-State Obese Type 2 Diabetes
Paniagua, J. A., López‐Miranda, J., Escribano, A., Berral, F. J., Marín, C., Bravo, D., Paz-Rojas, E., Gomez, P. J., Barcos, M., Moreno, J. A., et al. (2002) · Diabetes · doi:10.2337/diabetes.51.8.2596 · Cited by 76
Katsuki, A. (2002) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.87.6.2906 · Cited by 68
QUICKI Is a Useful and Accurate Index of Insulin Sensitivity
Quon, M. J. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.2.8223 · Cited by 53
Self-citationThe Minimal Model of Glucose Regulation: A Biography
Bergman, R. N. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-9019-8_1 · Cited by 41
QUICKI Does Not Accurately Reflect Changes in Insulin Sensitivity with Exercise Training
Duncan, G. E., Hutson, A. D., & Stacpoole, P. W. (2001) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.86.9.7830 · Cited by 40
Strączkowski, M., Stępień, A., Kowalska, I., & Kinalska, I. (2004) · PubMed · Cited by 37
Perseghin, G., Caumo, A., Mazzaferro, V., Pulvirenti, A., Sereni, L. P., Romito, R., Lattuada, G., Coppa, J. C., Costantino, F., Regalia, E., et al. (2003) · Transplantation · doi:10.1097/01.tp.0000079252.94857.8d · Cited by 26
Quon, M. J., Cochran, C., Taylor, S. I., & Eastman, R. C. (1994) · PubMed · Cited by 24
Self-citationPiatti, P., Monti, L. D., Caumo, A., Santambrogio, G., Magni, F., Galli-Kienle, M., Costa, S., Pontiroli, A. E., Alberti, K. G., & Pozza, G. (1995) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.80.1.34 · Cited by 24
What kind of simple fasting index should be used to estimate insulin sensitivity in humans?
Bastard, J., RABASA-LHORET, R. P. R., Maachi, M., Ducluzeau, P., Andréelli, F., Vidal, H., & Laville, M. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70038-1 · Cited by 21
Karne, R. J., Chen, H., & Quon, M. J. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1247-a · Cited by 20
Self-citationFasting Insulin Concentration Is Highly Correlated with Quantitative Insulin Sensitivity Check Index
Hauache, O. M., & Vieira, J. G. H. (2003) · Endocrine · doi:10.1385/endo:21:2:137 · Cited by 4
Cited by
Muniyappa, R., Lee, S., Chen, H., & Quon, M. J. (2008) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00645.2007 · Cited by 1,643
“In this regard, error functions for QUICKI and log (HOMA-IR) are both excellent and significantly smaller than for HOMA-IR, 1/HOMA-IR, fasting insulin, and SI derived from the minimal model (21).”
BackgroundMethodSelf-citationTrends in insulin resistance: insights into mechanisms and therapeutic strategy
Li, M., Chi, X., Wang, Y., Setrerrahmane, S., Xie, W., & Xu, H. (2022) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-022-01073-0 · Cited by 939
Surrogate markers of insulin resistance: A review
Singh, B. (2010) · World Journal of Diabetes · doi:10.4239/wjd.v1.i2.36 · Cited by 622
Glucose Regulation in Young Adults with Very Low Birth Weight
Hovi, P., Andersson, S., Eriksson, J. G., Järvenpää, A.-L., Strang-Karlsson, S., Mäkitie, O., & Kajantie, E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067187 · Cited by 523
Alemzadeh, R., Kichler, J., Babar, G., & Calhoun, M. (2008) · Metabolism · doi:10.1016/j.metabol.2007.08.023 · Cited by 419
Metadata
- Authors
- Chen, H., Sullivan, G., & Quon, M. J.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2005-07-01
- Volume
- 54
- Issue
- 7
- Pages
- 1914-1925
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2095973491
- Cited by
- 270
- References
- 45
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.