Improvement of HbA1c and Blood Glucose Stability in IDDM Patients Treated With Lispro Insulin Analog in External Pumps
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare the efficacy of the short-acting insulin analog lispro (LP) with that of regular insulin in IDDM patients treated with an external pump. RESEARCH DESIGN AND METHODS: Thirty-nine IDDM patients (age, 39.4 ± 1.5 years; sex ratio, 22M/17W; BMI, 24.4 ± 0.4 kg/m2; diabetes duration, 22.5 ± 1.6 years) who were treated by external pump for 5.1 ± 0.5 years were involved in an open-label, randomized, crossover multicenter study comparing two periods of 3 months of continuous subcutaneous insulin infusion with LP or with Actrapid HM, U-100 (ACT). Boluses were given 0–5 min (LP) or 20–30 min (ACT) before meals. Blood glucose (BG) was monitored before and after the three meals every day. RESULTS: The decrease in HbA1c was more pronounced with LP than with ACT (−0.62 ± 0.13 vs. −0.09 ± 0.15%, P = 0.01). BG levels were lower with LP (7.93 ± 0.15 vs. 8.61 ± 0.18 mmol/l, P < 0.0001), particularly postprandial BG levels (8.26 ± 0.19 vs. 9.90 ± 0.20 mmol/l, P < 0.0001). Standard deviations of all the BG values (3.44 ± 0.10 vs. 3.80 ± 0.10 mmol/l, P = 0.0001) and of postprandial BG values (3.58 ± 0.10 vs. 3.84 ± 0.10 mmol/l. P < 0.02) were lower with LP. The rate of hypoglycemic events defined by BG < 3.0 mmol/l did not significantly differ between LP and ACT (7.03 ± 0.94 vs. 7.94 ± 0.88 per month, respectively), but the rate of occurrences of very low BG, defined as BG < 2.0 mmol/l, were significantly reduced with LP (0.05 ± 0.05 vs. 0.47 ± 0.19 per month, P < 0.05). At the end of the study, all but two (95%) of the patients chose LP for the extension phase. CONCLUSIONS: When used in external pumps, LP provides better glycemic control and stability than regular insulin and does not increase the frequency of hypoglycemic episodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bode, B. W., Steed, R. D., & Davidson, P. C. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.324 · Cited by 257
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Outpatient Insulin Therapy in Type 1 and Type 2 Diabetes Mellitus: Scientific Review
DeWitt, D. E., & Hirsch, I. B. (2003) · JAMA · doi:10.1001/jama.289.17.2254 · Cited by 502
Pickup, J., Mattock, M., & Kerry, S. (2002) · BMJ · doi:10.1136/bmj.324.7339.705 · Cited by 483
Continuous Subcutaneous Insulin Infusion at 25 Years
Pickup, J., & Keen, H. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.593 · Cited by 397
Owens, D. R., Zinman, B., & Bolli, G. B. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05842-1 · Cited by 373
Insulin analogues and their potential in the management of diabetes mellitus
Bolli, G. B., Di Marchi, R. D., Park, G. D., Pramming, S., & Koivisto, V. A. (1999) · Diabetologia · doi:10.1007/s001250051286 · Cited by 349
Cummins, E., Royle, P., Snaith, A., Greene, A., Robertson, L., McIntyre, L., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14110 · Cited by 335
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Short acting insulin analogues versus regular human insulin in patients with diabetes mellitus
Siebenhofer, A., Plank, J., Berghold, A., Jeitler, K., Horvath, K., Narath, M., Gfrerer, R., & Pieber, T. R. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003287.pub4 · Cited by 264
Clinical and cost-effectiveness of continuous subcutaneous insulin infusion for diabetes
Colquitt, J., Green, C., Sidhu, M., Hartwell, D., & Waugh, N. (2004) · Health Technology Assessment · doi:10.3310/hta8430 · Cited by 249
“A similar proportion (18 to 23%) of patients in each group experienced catheter obstructions.(116,118) In addition, Raskin and colleagues(119) reported that eight (14%) patients using lispro and 12 (20%) patients using soluble insulin experienced 16 and 23 episodes of hyperglycaemia, respectively, caused by occlusion.”
Pańkowska, E., Błazik, M., Dziechciarz, P., Szypowska, A., & Szajewska, H. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00440.x · Cited by 209
“pumps, flexibility, and easier adaptation of insulin dosing for current physiological needs enable to reduce the risk of severe hypoglycemia in children with T1DM (8–10) and improve glycemic control in adults (11, 12).”
BackgroundDeVries, J. H., Snoek, F. J., Kostense, P. J., Masurel, N., Heine, R. J., & On behalf of the Dutch Insulin Pump Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2074 · Cited by 187
Bode, B., Weinstein, R., Bell, D., McGill, J., Nadeau, D., Raskin, P., Davidson, J., Henry, R., Huang, W.-C., & Reinhardt, R. R. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.439 · Cited by 148
“man regular insulin in CSII, in which the rate of blood glucose–confirmed hypoglycemia for the insulin analog group was slightly but not significantly lower than the rate for regular insulin group (7,23).”
BackgroundChase, H. P., Saib, S. Z., MacKenzie, T., Hansen, M. M., & Garg, S. K. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00685.x · Cited by 116
Raskin, P., Holcombe, J. H., Tamborlane, W. V., Malone, J. I., Strowig, S., Ahern, J. A., & Lavent, F. (2001) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(01)00168-4 · Cited by 71
Implantable insulin pumps. A position statement about their clinical use
Renard, E., & Schaepelynck-Bélicar, P. (2007) · Diabetes & Metabolism · doi:10.1016/j.diabet.2006.10.004 · Cited by 69
Hoogma, R., & Schumicki, D. (2006) · Hormone and Metabolic Research · doi:10.1055/s-2006-944549 · Cited by 66
Nørgaard, K., Sukumar, N., Rafnsson, S. B., & Saravanan, P. (2018) · Diabetes Therapy · doi:10.1007/s13300-018-0411-7 · Cited by 26
Pratoomsoot, C., Smith, H. T., Kalsekar, A., Boye, K. S., Arellano, J., & Valentine, W. J. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2009.02775.x · Cited by 18
Metadata
- Authors
- Melki, V., Renard, E., Lassmann-Vague, V., Boivin, S., Guerci, B., Hanaire-Broutin, H., Bringer, J., Belicar, P., Jeandidier, N., Meyer, L., Blin, P., Augendre-Ferrante, B., & Tauber, J.-P.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1998-06-01
- Volume
- 21
- Issue
- 6
- Pages
- 977-982
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2028053635
- Cited by
- 138
- References
- 1
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.