A soft wearable robot for tremor assessment and suppression
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Tremor constitutes the most common motor disorder, and poses a functional problem to a large number of patients. Despite of the considerable experience in tremor management, current treatment based on drugs or surgery does not attain an effective attenuation in 25 % of patients, motivating the need for research in new therapeutic alternatives. In this context, this paper presents the concept design, development, and preliminary validation of a soft wearable robot for tremor assessment and suppression. The TREMOR neurorobot comprises a Brain Neural Computer Interface that monitors the whole neuromusculoskeletal system, aiming at characterizing both voluntary movement and tremor, and a Functional Electrical Stimulation system that compensates for tremulous movements without impeding the user perform functional tasks. First results demonstrate the performance of the TREMOR neurorobot as a novel means of assessing and attenuating pathological tremors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 3×
“We are currently evaluating two tremor suppression strategies: one based on impedance control, the other on learning control techniques, [5].”
BackgroundMethodInfluentialSelf-citationWenning, G. K., Kiechl, S., Seppi, K., Müller, J., Högl, B., Saletu, M., Rungger, G., Gasperi, A., Willeit, J., & Poewe, W. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70226-x · Cited by 302 · cited 1×
“This pathological tremors constitute the most common motor disorder, affecting 15 % of people with ages ranging between 50 and 69 years [1].”
BackgroundAdaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 1×
“The first algorithm is the Weighted Frequency Fourier Linear Combiner (WFLC), which is employed to track tremor frequency based on a LMS approach, [16].”
MethodThe effects of load and force on tremor at the normal human elbow joint
Joyce, G. C., & Rack, P. M. H. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010615 · Cited by 167 · cited 1×
“This work relied on the known effects of impedance modulation in tremor, [6], and provided with up to 80 % tremor attenuation in severe cases, without impeding the user to perform functional tasks.”
MethodAttenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 1×
“Notice that attenuation of writs tremors based on muscle stimulation has been previously evaluated in [7], demonstrating the feasibility of the approach.”
MethodReal-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Self-citationPathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89 · cited 1×
“Moreover, among people suffering from upper limb tremors, 65 % of them report severe disability to perform their activities of daily living [2].”
BackgroundSelf-citationOptimal digital filtering for tremor suppression
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56 · cited 1×
“Next, the performance of the tremor estimation algorithm is evaluated by computing the Filtered Mean Square Error with Delay Correction (FMSEd), a metric specifically proposed for tremor tracking filters, [23].”
MethodBiomechanical Modelling of the Upper Limb for Robotics-Based Orthotic Tremor Suppression
Rocon, E., Ruiz, A. F., & Pons, J. L. (2005) · Applied Bionics and Biomechanics · doi:10.1155/2005/535893 · Cited by 18 · cited 1×
“Considering that a human joint may be simply modelled as a second order system, [17], increased rigidity or damping decreases the cut off frequency of the low pass filter response of the joint, hence allowing for tremor attenuation.”
BackgroundSelf-citation
Research works printed but not linked: 15
- 10.1109/9.1274 · DOI · Paper page
- 10.1109/TAC.1984.1103644 · DOI · Paper page
- 10.1007/s00422-009-0348-z · DOI
- riley, 1987, Evaluating manual control devices for those with tremor disability, J Rehabil Res Dev, 24, 99
- 10.1016/S1388-2457(99)00141-8 · DOI · Paper page
- 10.1109/TASL.2006.889744 · doi:10.1109/tasl.2006.889744
- 10.1111/j.1525-1594.2005.29075.x · DOI · Paper page
- 10.1088/0967-3334/28/4/007 · DOI · Paper page
- 10.1109/IEMBS.2010.5627630 · DOI
- louis, 2009, Essential tremors: A family of neurodegenerative disorders?, Arch Neurol, 66, 1202, 10.1001/archneurol.2009.217 · DOI · Paper page
- iba?ez, 2010, An asynchronous bmi system for online single-trial detection of movement intention, Conf Proc IEEE Eng Med Biol Soc
- paradiso, 2010, E-textile platforms for rehabilitation, Conf Proc IEEE Eng Med Biol Soc
- 10.1159/000075156 · DOI · Paper page
- 10.1002/9780470987667 · DOI · Paper page
- belda-lois, 2005, Functional assessment of tremor in the upper limb, Euro Conf Advancement Assistive Techn in Europe
Cited by
Lee, C., Kim, M., Kim, Y. J., Hong, N., Ryu, S., Kim, H. J., & Kim, S. (2017) · International Journal of Control, Automation and Systems · doi:10.1007/s12555-016-0462-3 · Cited by 616
Peripheral electrical stimulation to reduce pathological tremor: a review
Pascual-Valdunciel, A., Hoo, G. W., Avrillon, S., Barroso, F. O., Goldman, J. G., Hernandez-Pavon, J. C., & Pons, J. L. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00811-9 · Cited by 66
Self-citationA Soft Exoskeleton for Tremor Suppression Equipped with Flexible Semiactive Actuator
Zahedi, A., Zhang, B., Yi, A., & Zhang, D. (2021) · Soft Robotics · doi:10.1089/soro.2019.0194 · Cited by 57
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
An experimental investigation of essential hand tremor suppression via a soft exoskeletal glove
Skaramagkas, V., Andrikopoulos, G., & Manesis, S. (2020) · 2020 European Control Conference (ECC) · doi:10.23919/ecc51009.2020.9143932 · Cited by 19
Metadata
- Authors
- Gallego, J. A., Rocon, E., Ibanez, J., Dideriksen, J. L., Koutsou, A. D., Paradiso, R., Popovic, M. B., Belda-Lois, J. M., Gianfelici, F., Farina, D., Popovic, D. B., Manto, M., D'Alessio, T., & Pons, J. L.
- Venue
- 2011 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 2249-2254
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2170147781
- Cited by
- 38
- References
- 9
- FWCI
- 8.82
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A soft wearable robot for tremor assessment and suppression. https://app.cochat.ai/papers/10.1109/icra.2011.5979639
- The paper
- Gallego, J. A., Rocon, E., Ibanez, J., Dideriksen, J. L., Koutsou, A. D., Paradiso, R., Popovic, M. B., Belda-Lois, J. M., Gianfelici, F., Farina, D., Popovic, D. B., Manto, M., D'Alessio, T., & Pons, J. L. (2011). A soft wearable robot for tremor assessment and suppression. 2011 IEEE International Conference on Robotics and Automation. https://doi.org/10.1109/icra.2011.5979639
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.