Development of a Wearable Tremor Suppression Glove
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Current treatments for parkinsonian tremor, such as medication and brain surgery, have shown varying levels of effectiveness and carry the risk of significant side effects and complications. Studies on wearable tremor suppression devices have shown positive results in the use of mechanical and electrical suppression on tremor management of the upper limbs. Wearable technology for tremor suppression is a promising solution for patients who do not respond to medication and do not present severe enough symptoms to undergo surgery. Available tremor suppression devices are mainly for elbow and wrist tremor. Devices for finger tremor suppression have not been developed despite the fact that finger tremor is also present. In this study, a wearable tremor suppression glove prototype was designed and validated with recorded tremor data from patients with Parkinson's disease. Two validation experiments were conducted to assess the performance of the proposed device when suppressing tremor motion and following voluntary motion. The tremor suppression assessment showed an overall tremor amplitude reduction of 85.0% ± 8.1%, and the power reductions for the 1st, 2nd, and 3rd harmonics are 87.9% ± 13.6%, 92.0% ± 7.4%, and 81.7% ± 13.0%, respectively. Following voluntary motion was possible with a RMSE of 14.2% ± 2.5% and a correlation coefficient of 0.97 ± 0.01. Both assessments have shown positive results for the validation of the proposed device; however, further work is needed to improve the performance of the proposed device prior to human trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720
Rascol, O., Brooks, D. J., Korczyn, A. D., De Deyn, P. P., Clarke, C. E., & Lang, A. E. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422004 · Cited by 1,539
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 1×
“A number of algorithms have been proposed to estimate tremor, such as Fourier Linear Combiner (FLC) [22], Weighted-frequency Fourier Linear Combiner (WFLC) and its derivatives [23, 24], and Kalman filter based estimators [25].”
MethodDeep Brain Stimulation and Tremor
Lyons, K. E., & Pahwa, R. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2008.01.004 · Cited by 143 · cited 1×
“Current treatments for PD are medication and brain surgery [8, 9].”
BackgroundOnline tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
An adaptive estimation of periodic signals using a Fourier linear combiner
Vaz, C., Kong, X., & Thakor, N. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.258116 · Cited by 108 · cited 2×
“A number of algorithms have been proposed to estimate tremor, such as Fourier Linear Combiner (FLC) [22], Weighted-frequency Fourier Linear Combiner (WFLC) and its derivatives [23, 24], and Kalman filter based estimators [25].”
MethodRehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87 · cited 3×
“In particular, the Wearable Orthosis for Tremor Assessment and Suppression (WOTAS) showed superior performance, with a 90% suppression rate for tremor amplitude [13].”
BackgroundBandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Veluvolu, K. C., Tan, U. X., Latt, W. T., Shee, C. Y., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352922 · Cited by 83
Zhou, Y., Naish, M. D., Jenkins, M. E., & Trejos, A. L. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2016.12.009 · Cited by 46
Self-citationPhenomenology and treatment of tremor disorders
Zesiewicz, T. A., & Hauser, R. A. (2001) · Neurologic Clinics · doi:10.1016/s0733-8619(05)70039-6 · Cited by 43
Research works printed but not linked: 15
- 10.1007/s00415-005-4005-8 · DOI
- kazi, 2010, Experimental implementation of smart glove incorporating piezoelectric actuator for hand tremor control, WSEAS Transactions on Systems and Control, 5, 443
- 10.1109/TNSRE.2013.2295034 · DOI · Paper page
- widjaja, 2008, Current progress on pathological tremor modeling and active compensation using functional electrical stimulation, ISG'08 The 6th Conference of the International Society for Gerontechnology, 1
- bó, 2009, FES-controlled co-contraction strategies for pathological tremor compensation, IEEE/RSJ International Conference on Intelligent Robots and Systems, 1633
- 10.1016/j.conengprac.2010.08.009 · DOI · Paper page
- 10.1109/TMECH.2011.2144614 · DOI · Paper page
- 10.5772/7382 · DOI
- elble, 1990, Tremor, 54
- smaga, 2003, Tremor-problem-oriented diagnosis, American Family Physician, 68, 1545
- 10.1111/j.1472-8206.1993.tb00226.x · DOI · Paper page
- charles, 1999, Classification of tremor and update on treatment, American Family Physician, 59, 1565
- 10.1001/jama.2014.1397 · DOI · Paper page
- 10.1109/BHI.2018.8333369 · DOI
- 10.1109/CCECE.2018.8447595 · DOI
Cited by
A Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
A Novel Soft Glove for Hand Tremor Suppression: Evaluation of Layer Jamming Actuator Placement
Awantha, W. V. I., Wanasinghe, A. T., Kavindya, A. G. P., Kulasekera, A. L., & Chathuranga, D. S. (2020) · 2020 3rd IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft48309.2020.9115994 · Cited by 31
An experimental investigation of essential hand tremor suppression via a soft exoskeletal glove
Skaramagkas, V., Andrikopoulos, G., & Manesis, S. (2020) · 2020 European Control Conference (ECC) · doi:10.23919/ecc51009.2020.9143932 · Cited by 19
Ibrahim, A., Zhou, Y., Jenkins, M. E., Luisa Trejos, A., & Naish, M. D. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176132 · Cited by 15
“As an alternative to existing treatments, wearable assistive devices have been recognized as a potential approach to assist with tremor [4]–[6].”
Self-citationZhou, Y., Habibollahi, Z., Ibrahim, A., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3211450 · Cited by 8
Self-citation
Metadata
- Authors
- Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L.
- Venue
- 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob)
- Publisher
- IEEE
- Published
- 2018-08
- Pages
- 640-645
- OpenAlex
- W2897337048
- Cited by
- 55
- References
- 13
- FWCI
- 9.62
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Wearable Tremor Suppression Glove. https://app.cochat.ai/papers/10.1109/biorob.2018.8487197
- The paper
- Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018). Development of a Wearable Tremor Suppression Glove. 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob). https://doi.org/10.1109/biorob.2018.8487197
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.