CoChat

Development of a Wearable Tremor Suppression Glove

Zhou, Yue, Jenkins, Mary E., Naish, Michael D., Trejos, Ana Luisa · 2018 · 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob)
Cited by 55

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Current treatments for parkinsonian tremor, such as medication and brain surgery, have shown varying levels of effectiveness and carry the risk of significant side effects and complications. Studies on wearable tremor suppression devices have shown positive results in the use of mechanical and electrical suppression on tremor management of the upper limbs. Wearable technology for tremor suppression is a promising solution for patients who do not respond to medication and do not present severe enough symptoms to undergo surgery. Available tremor suppression devices are mainly for elbow and wrist tremor. Devices for finger tremor suppression have not been developed despite the fact that finger tremor is also present. In this study, a wearable tremor suppression glove prototype was designed and validated with recorded tremor data from patients with Parkinson's disease. Two validation experiments were conducted to assess the performance of the proposed device when suppressing tremor motion and following voluntary motion. The tremor suppression assessment showed an overall tremor amplitude reduction of 85.0% ± 8.1%, and the power reductions for the 1st, 2nd, and 3rd harmonics are 87.9% ± 13.6%, 92.0% ± 7.4%, and 81.7% ± 13.0%, respectively. Following voluntary motion was possible with a RMSE of 14.2% ± 2.5% and a correlation coefficient of 0.97 ± 0.01. Both assessments have shown positive results for the validation of the proposed device; however, further work is needed to improve the performance of the proposed device prior to human trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/biorob.2018.8487197

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Research works printed but not linked: 15

  1. 10.1007/s00415-005-4005-8 · DOI
  2. kazi, 2010, Experimental implementation of smart glove incorporating piezoelectric actuator for hand tremor control, WSEAS Transactions on Systems and Control, 5, 443
  3. 10.1109/TNSRE.2013.2295034 · DOI · Paper page
  4. widjaja, 2008, Current progress on pathological tremor modeling and active compensation using functional electrical stimulation, ISG'08 The 6th Conference of the International Society for Gerontechnology, 1
  5. bó, 2009, FES-controlled co-contraction strategies for pathological tremor compensation, IEEE/RSJ International Conference on Intelligent Robots and Systems, 1633
  6. 10.1016/j.conengprac.2010.08.009 · DOI · Paper page
  7. 10.1109/TMECH.2011.2144614 · DOI · Paper page
  8. 10.5772/7382 · DOI
  9. elble, 1990, Tremor, 54
  10. smaga, 2003, Tremor-problem-oriented diagnosis, American Family Physician, 68, 1545
  11. 10.1111/j.1472-8206.1993.tb00226.x · DOI · Paper page
  12. charles, 1999, Classification of tremor and update on treatment, American Family Physician, 59, 1565
  13. 10.1001/jama.2014.1397 · DOI · Paper page
  14. 10.1109/BHI.2018.8333369 · DOI
  15. 10.1109/CCECE.2018.8447595 · DOI

Cited by

See all 55

Metadata

Authors
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L.
Venue
2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob)
Publisher
IEEE
Published
2018-08
Pages
640-645
OpenAlex
W2897337048
Cited by
55
References
13
FWCI
9.62
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a Wearable Tremor Suppression Glove. https://app.cochat.ai/papers/10.1109/biorob.2018.8487197
The paper
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018). Development of a Wearable Tremor Suppression Glove. 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob). https://doi.org/10.1109/biorob.2018.8487197

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.