The DOI matches its Crossref record.
Steering Magnetic Nanoparticles by Utilizing an Adjustable Linear Halbach Array
Abstract
Magnetic nanoparticles offer numerous promising biomedical applications, e. g. magnetic drug targeting. Here, magnetic drug carriers inside the human body are manipulated towards tumorous tissue by an external magnetic field. However, the success of the treatment depends strongly on the amount of drug carries, reaching the desired tumor region. This steering process is still an open research topic. In the proposed paper, an adjustable linear Halbach array to steer magnetic nanoparticles is investigated numerically using COMSOL Multiphysics. This Halbach array produces a relatively large region of a high magnetic field, while having a strong gradient. This results in a strong magnetic force, trapping many particles at the magnet. To avoid particle agglomeration, the Halbach array is rotated to its weak side. In this context, the force on the nanoparticles is evaluated for different magnet rotation angles. Comparing the weak and the strong magnetic side, the maximum and average magnetic force is a factor of 2.1 and 1.5 higher, respectively. Overall, the results depict the magnetic force and, thus, the region where the particles are able to get washed out, can be adjusted.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 20
- 10.1016/j.jmmm.2016.11.016 · DOI
- 10.1016/j.jmmm.2010.07.022 · DOI
- 10.1109/MNANO.2020.2966029 · DOI
- sakuma, 2021, Optimization of rotation patterns of a mangle-type magnetic field source using covariance matrix adaptation evolution strategy, Journal of Magnetism and Magnetic Materials, 527, 10.1016/j.jmmm.2021.167752 · DOI · Paper page
- 10.1016/j.jmmm.2017.05.001 · DOI
- 10.1016/j.jmmm.2012.02.014 · DOI · Paper page
- 10.1109/TMAG.2013.2244577 · DOI
- 10.1063/1.4952612 · DOI · Paper page
- jackson, 1998, Classical Electrodynamics
- 10.1002/9780470386323 · DOI
- 10.1109/TASC.2005.864457 · DOI
- 10.1109/TUFFC.2021.3068791 · DOI
- 10.1016/j.nano.2013.05.001 · DOI · Paper page
- mues, 2021, Nanomagnetic actuation of hybrid stents for hyperthermia treatment of hollow organ tumors, Nanomater (Basel Switzerland), 11
- 10.3390/ecsa-7-08269 · DOI
- 10.2147/IJN.S68539 · DOI
- 10.1109/TMAG.2020.3023686 · DOI
- 10.1109/MCS.2012.2189052 · DOI
- 10.1109/ACCESS.2020.3000329 · DOI
- 10.1155/2018/6246917 · DOI
Cited by
Sorted by citations
Thalmayer, A. S., Götz, K., Lübke, M., & Fischer, G. (2024) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2024-2159
Self-citation
Metadata
- Authors
- Thalmayer, A. S., Zeising, S., Fischer, G., & Kirchner, J.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Venue
- 2021 Kleinheubach Conference
- Publisher
- IEEE
- Published
- 2021-09-28
- Pages
- 1-4
- OpenAlex
- W3212062306
- Cited by
- 13
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2023: 5 · 2022: 2
- FWCI
- 5.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Kleinheubach Conference (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
- Keywords
- magnetic nanoparticles, Halbach array, magnetic steering, magnetic drug delivery, magnetic force, magnetic field gradient, particle agglomeration, magnetic drug carriers, tumor targeting
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review