The validation of Fitbit Zip™ physical activity monitor as a measure of free-living physical activity
Open accessAbstract
BACKGROUND: The new generation of activity monitors allow users to upload their data to the internet and review progress. The aim of this study is to validate the Fitbit Zip as a measure of free-living physical activity. FINDINGS: Participants wore a Fitbit Zip, ActiGraph GT3X accelerometer and a Yamax CW700 pedometer for seven days. Participants were asked their opinion on the utility of the Fitbit Zip. Validity was assessed by comparing the output using Spearman's rank correlation coefficients, Wilcoxon signed rank tests and Bland-Altman plots. 59.5% (25/47) of the cohort were female. There was a high correlation in steps/day between the Fitbit Zip and the two reference devices (r = 0.91, p < 0.001). No statistically significant difference between the Fitbit and Yamax steps/day was observed (Median (IQR) 7477 (3597) vs 6774 (3851); p = 0.11). The Fitbit measured significantly more steps/day than the Actigraph (7477 (3597) vs 6774 (3851); p < 0.001). Bland-Altman plots revealed no systematic differences between the devices. CONCLUSIONS: Given the high level of correlation and no apparent systematic biases in the Bland Altman plots, the use of Fitbit Zip as a measure of physical activity. However the Fitbit Zip recorded a significantly higher number of steps per day than the Actigraph.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Fitbit ZipTM has been found to be a valid measure of free-living physical activity in healthy adults.
“The Fitbit ZipTM has been found to be a valid measure of free-living physical activity in healthy adults [60].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · see citing works
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619 · see citing works
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · see citing works
Evidence-based intervention in physical activity: lessons from around the world
Heath, G. W., Parra, D. C., Sarmiento, O. L., Andersen, L. B., Owen, N., Goenka, S., Montes, F., & Brownson, R. C. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60816-2 · Cited by 1,199 · see citing works
Meta-analysis of internet-delivered interventions to increase physical activity levels
Davies, C. A., Spence, J. C., Vandelanotte, C., Caperchione, C. M., & Mummery, W. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-52 · Cited by 488 · see citing works
Comparison of pedometer and accelerometer measures of free-living physical activity
Tudor-Locke, C. E., Ainsworth, B. E., Thompson, R. W., & Matthews, C. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00027 · Cited by 387 · see citing works
Validation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2013) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 322 · see citing works
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202 · see citing works
A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitors
Dannecker, K. L., Sazonova, N. A., Melanson, E. L., Sazonov, E. E., & Browning, R. C. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318299d2eb · Cited by 124 · see citing works
Protocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124 · see citing works
Dowd, K., Harrington, D. M., & Donnelly, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047633 · Cited by 120 · see citing works
Hale, L. A., Pal, J., & Becker, I. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.027 · Cited by 118 · see citing works
Validation of the Fitbit Wireless Activity Tracker for Prediction of Energy Expenditure
Sasaki, J. E., Hickey, A., Mavilia, M. G., Tedesco, J., John, D., Keadle, S. K., & Freedson, P. S. (2014) · Journal of Physical Activity and Health · doi:10.1123/jpah.2012-0495 · Cited by 116 · see citing works
Bassett, D., Mahar, M., Rowe, D., & Morrow, J. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31817c699c · Cited by 69 · see citing works
Kolt, G. S., Rosenkranz, R. R., Savage, T. N., Maeder, A. J., Vandelanotte, C., Duncan, M. J., Caperchione, C. M., Tague, R., Hooker, C., & Mummery, W. K. (2013) · BMC Public Health · doi:10.1186/1471-2458-13-436 · Cited by 35 · see citing works
Dondzila, C. J., Swartz, A. M., Miller, N. E., Lenz, E. K., & Strath, S. J. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-143 · Cited by 31 · see citing works
Cocker, K. A. D., Cardon, G., & Bourdeaudhuij, I. D. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.025296 · Cited by 20 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · see citing works
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616 · see citing works
Sullivan, A. N., & Lachman, M. E. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2016.00289 · Cited by 458 · see citing works
Lobelo, F., Rohm Young, D., Sallis, R., Garber, M. D., Billinger, S. A., Duperly, J., Hutber, A., Pate, R. R., Thomas, R. J., Widlansky, M. E., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000559 · Cited by 402 · see citing works
Reliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360 · see citing works
Mantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314 · see citing works
Xie, J., Wen, D., Liang, L., Jia, Y., Gao, L., & Lei, J. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9754 · Cited by 310 · see citing works
Remote Physical Activity Monitoring in Neurological Disease: A Systematic Review.
Block, V. A. J., Pitsch, E., Tahir, P., Cree, B. A. C., Allen, D. D., & Gelfand, J. M. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154335 · Cited by 198 · see citing works
Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
Paul, S. S., Tiedemann, A., Hassett, L. M., Ramsay, E., Kirkham, C., Chagpar, S., & Sherrington, C. (2015) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000013 · Cited by 164 · see citing works
Rykov, Y., Thach, T.-Q., Bojic, I., Christopoulos, G., & Car, J. (2021) · JMIR mHealth and uHealth · doi:10.2196/24872 · Cited by 151 · see citing works
Walk to a better night of sleep: testing the relationship between physical activity and sleep
Bisson, A., Robinson, S. A., & Lachman, M. E. (2019) · Sleep Health · doi:10.1016/j.sleh.2019.06.003 · Cited by 149 · see citing works
Alharbi, M., Bauman, A. E., Neubeck, L., & Gallagher, R. D. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316634883 · Cited by 141 · see citing works
Jo, A., Coronel, B. D., Coakes, C. E., & Mainous, A. G. (2019) · The American Journal of Medicine · doi:10.1016/j.amjmed.2019.06.018 · Cited by 132 · see citing works
How valid are wearable physical activity trackers for measuring steps?
An, H., Jones, G. C., Kang, S., Welk, G. J., & Lee, J. M. (2016) · European Journal of Sport Science · doi:10.1080/17461391.2016.1255261 · Cited by 131 · see citing works
Cosoli, G., Spinsante, S., & Scalise, L. (2020) · Measurement · doi:10.1016/j.measurement.2020.107789 · Cited by 122 · see citing works
Imboden, M. T., Nelson, M. B., Kaminsky, L. A., & Montoye, A. H. K. (2017) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-096990 · Cited by 119 · see citing works
Wong, C. A., Madanay, F. L., Ozer, E. M., Harris, S. K., Moore, M., Master, S. O., Moreno, M. A., & Weitzman, E. R. (2020) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2019.10.018 · Cited by 119 · see citing works
Adams, M. A., Hurley, J. C., Todd, M., Bhuiyan, N., Jarrett, C. L., Tucker, W. J., Hollingshead, K. E., & Angadi, S. S. (2017) · BMC Public Health · doi:10.1186/s12889-017-4197-8 · Cited by 110 · see citing works
Dominick, G. M., Winfree, K. N., Pohlig, R. T., & Papas, M. A. (2016) · JMIR mhealth and uhealth · doi:10.2196/mhealth.6281 · Cited by 102 · see citing works
Lee, H. A., Lee, H., Moon, J.-H., Lee, T., Kim, M.-G., In, H., Cho, C., & Kim, L. (2017) · Psychiatry Investigation · doi:10.4306/pi.2017.14.2.179 · Cited by 102 · see citing works
Gomersall, S. R., Ng, N., Burton, N. W., Pavey, T., Gilson, N. D., & Brown, W. J. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5531 · Cited by 90 · see citing works
Brewer, W., Swanson, B. T., & Ortíz, A. (2017) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2017-000254 · Cited by 89 · see citing works
Chow, J. J., Thom, J. M., Wewege, M. A., Ward, R. E., & Parmenter, B. J. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.012 · Cited by 88 · see citing works
Thorup, C. B., Hansen, J., Grønkjær, M., Andreasen, J. J., Nielsen, G. N., Sørensen, E. E., & Dinesen, B. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5191 · Cited by 87 · see citing works
Promise of Wearable Physical Activity Monitors in Oncology Practice
Beg, M. S., Gupta, A., Stewart, T. F., & Rethorst, C. D. (2017) · Journal of Oncology Practice · doi:10.1200/jop.2016.016857 · Cited by 85 · see citing works
Step-Based Physical Activity Metrics and Cardiometabolic Risk
Tudor-Locke, C. E., Schuna, J. M., Han, H., Aguiar, E. J., GREEN, M. A., Busa, M. A., Larrivée, S., & Johnson, W. D. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001100 · Cited by 81 · see citing works
Meng, Y., Speier, W. F., SHUFELT, C. L., Joung, S. Y., Eyk, J. E. V., Merz, C. N. B., Lopez, M., Spiegel, B. M. R., & Arnold, C. W. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2922178 · Cited by 78 · see citing works
Alinia, P., Cain, C. R., Fallahzadeh, R., Shahrokni, A., Cook, D. J., & Ghasemzadeh, H. G. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.6321 · Cited by 75 · see citing works
Leth, S., Hansen, J., Nielsen, O., & Dinesen, B. (2017) · Sensors · doi:10.3390/s17010211 · Cited by 64 · see citing works
An Evaluation of Commercial Pedometers for Monitoring Slow Walking Speed Populations
Beevi, F. H. A., Miranda, J., Pedersen, C. F., & Wagner, S. (2015) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0120 · Cited by 62 · see citing works
Validity of Commercial Activity Trackers in Children With Congenital Heart Disease
Voss, C., Gardner, R. F., Dean, P. H., & Harris, K. C. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.11.024 · Cited by 61 · see citing works
Losina, E., Collins, J. E., Deshpande, B. R., Smith, S. R., Michl, G. L., Usiskin, I. M., Klara, K. M., Winter, A. R., Yang, H. Y., Selzer, F., et al. (2017) · Arthritis Care & Research · doi:10.1002/acr.23324 · Cited by 61 · see citing works
Degroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60 · see citing works
Information in the Biosphere: Biological and Digital Worlds
Gillings, M. R., Hilbert, M., & Kemp, D. J. (2016) · Trends in Ecology & Evolution · doi:10.1016/j.tree.2015.12.013 · Cited by 60 · see citing works
Thorup, C. B., Grønkjær, M., Spindler, H., Andreasen, J. J., Hansen, J., Dinesen, B., Nielsen, G. N., & Sørensen, E. E. (2016) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-016-0048-7 · Cited by 58 · see citing works
Validation of the Fitbit Zip for monitoring physical activity among free-living adolescents
Schneider, M. L., & Chau, L. (2016) · BMC Research Notes · doi:10.1186/s13104-016-2253-6 · Cited by 56 · see citing works
Polgreen, L. A., Anthony, C., Carr, L., Simmering, J. E., Evans, N. J., Foster, E. D., Segre, A. M., Cremer, J. F., & Polgreen, P. M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0195797 · Cited by 52 · see citing works
Physical activity and atrial fibrillation: Data from wearable fitness trackers
Semaan, S., Dewland, T. A., Tison, G. H., Nah, G., Vittinghoff, E., Pletcher, M. J., Olgin, J. E., & Marcus, G. M. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.02.013 · Cited by 52 · see citing works
Mikkelsen, M.-L. K., Berg‐Beckhoff, G., Frederiksen, P., Horgan, G. W., O’Driscoll, R., Palmeira, A. L., Scott, S., Stubbs, R. J., Heitmann, B. L., & Larsen, S. C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0234426 · Cited by 51 · see citing works
Older women’s perceptions of wearable and smart home activity sensors
Reeder, B., Chung, J., Lyden, K. A., Winters, J. D., & Jankowski, C. M. (2019) · Informatics for Health and Social Care · doi:10.1080/17538157.2019.1582054 · Cited by 49 · see citing works
Huffman, J. C., Adams, C. N., & Celano, C. M. (2017) · Psychosomatics · doi:10.1016/j.psym.2017.09.003 · Cited by 48 · see citing works
Giurgiu, M., Timm, I., Becker, M. L., Schmidt, S., Wunsch, K., Nissen, R., Davidovski, D., Bussmann, J. B. J., Nigg, C. R., Reichert, M., et al. (2022) · JMIR mhealth and uhealth · doi:10.2196/36377 · Cited by 46 · see citing works
Stelzer, E., Book, S., Graessel, E., Hofner, B., Kornhuber, J., & Luttenberger, K. (2018) · Heliyon · doi:10.1016/j.heliyon.2018.e00580 · Cited by 46 · see citing works
The Validity of Consumer-Level Activity Monitors in Healthy Older Adults in Free-Living Conditions
Farina, N., & Lowry, R. (2017) · Journal of Aging and Physical Activity · doi:10.1123/japa.2016-0344 · Cited by 45 · see citing works
Thorup, C. B., Andreasen, J. J., Sørensen, E. E., Grønkjær, M., Dinesen, B., & Hansen, J. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-011742 · Cited by 43 · see citing works
O'Brien, M. W., Wojcik, W. R., & Fowles, J. R. (2018) · JMIR mhealth and uhealth · doi:10.2196/10706 · Cited by 43 · see citing works
The therapeutic effects of climbing: A systematic review and meta‐analysis
Gassner, L., Dabnichki, P., Langer, A., Pokan, R., Zach, H., Ludwig, M., & Santer, A. (2022) · PM&R · doi:10.1002/pmrj.12891 · Cited by 40 · see citing works
Physical activity intervention using Fitbits in an introductory college health course
Rote, A. E. (2016) · Health Education Journal · doi:10.1177/0017896916674505 · Cited by 39 · see citing works
Fitbit Flex: an unreliable device for longitudinal sleep measures in a non-clinical population
Baroni, A., Bruzzese, J., Bartolo, C. A. D., & Shatkin, J. P. (2015) · Sleep And Breathing · doi:10.1007/s11325-015-1271-2 · Cited by 37 · see citing works
Measuring the fitness of fitness trackers
Bender, C. G., Hoffstot, J. C., Combs, B. T., Hooshangi, S., & Cappos, J. (2017) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2017.7894077 · Cited by 36 · see citing works
Janevic, M. R., Shute, V., Murphy, S. L., & Piette, J. D. (2019) · Pain Medicine · doi:10.1093/pm/pnz215 · Cited by 35 · see citing works
Beagle, A. J., Tison, G. H., Aschbacher, K., Olgin, J. E., Marcus, G. M., & Pletcher, M. J. (2020) · JMIR mhealth and uhealth · doi:10.2196/22090 · Cited by 35 · see citing works
Buckinx, F., Mouton, A., Reginster, J.-Y., Croisier, J. ‐., Dardenne, N., Beaudart, C., Nelis, J., Lambert, E., Appelboom, G., & Bruyère, O. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.02.010 · Cited by 35 · see citing works
Liu, J. Y. W., Kwan, R. Y. C., Yin, Y., Lee, P. H., Siu, J. Y., & Bai, X. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph181910344 · Cited by 34 · see citing works
Wearables for health and fitness: Measurement characteristics and accuracy
Scalise, L., & Cosoli, G. (2018) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2018.8409635 · Cited by 34 · see citing works
Lister, N. B., Jebeile, H., Truby, H., Garnett, S. P., Varady, K. A., Cowell, C. T. C. T., Collins, C. E., Paxton, S. J., Gow, M. L., Brown, J. J., et al. (2019) · Obesity Research & Clinical Practice · doi:10.1016/j.orcp.2019.11.005 · Cited by 32 · see citing works
Vaughn, N. H., Dunklebarger, M., & Mason, M. W. (2018) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000000591 · Cited by 31 · see citing works
Comparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30 · see citing works
Mooses, K., Oja, M., Reisberg, S., Vilo, J., & Kull, M. (2018) · BMC Public Health · doi:10.1186/s12889-018-5752-7 · Cited by 30 · see citing works
Activity Tracker–Based Metrics as Digital Markers of Cardiometabolic Health: Cross-Sectional Study
Rykov, Y., Thach, T.-Q., Dunleavy, G., Roberts, A. C., Christopoulos, G., Soh, C. K., & Car, J. (2020) · JMIR mHealth and uHealth · doi:10.2196/16409 · Cited by 29 · see citing works
Biventricular Pacing Versus Right Ventricular Pacing in Patients Supported With LVAD
Chung, B., Grinstein, J., Imamura, T., Kruse, E., Nguyen, A. B., Narang, N., Holzhauser, L., Burkhoff, D., Lang, R. M., Sayer, G. T., et al. (2021) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2021.01.016 · Cited by 29 · see citing works
Breteler, M. J. M., Janssen, J. H., Spiering, W., Kalkman, C. J., van Solinge, W. W., & Dohmen, D. (2019) · JMIR Formative Research · doi:10.2196/11489 · Cited by 29 · see citing works
Ng, K., Tynjälä, J., & Kokko, S. P. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.6940 · Cited by 28 · see citing works
Gaz, D. V., Rieck, T. M., Peterson, N. W., Ferguson, J. A., Schroeder, D. R., Dunfee, H. A., Henderzahs-Mason, J. M., & Hagen, P. T. (2018) · American Journal of Health Promotion · doi:10.1177/0890117118763273 · Cited by 27 · see citing works
Brewer, L. C., Kaihoi, B., Zarling, K. K., Squires, R. W., Thomas, R. J., & Kopecky, S. L. (2015) · JMIR Research Protocols · doi:10.2196/resprot.4285 · Cited by 27 · see citing works
Finkelstein, E. A., Sahasranaman, A., John, G., Haaland, B. A., Bilger, M., Sloan, R. A., Khaing, N. E. E., & Evenson, K. R. (2015) · Contemporary Clinical Trials · doi:10.1016/j.cct.2015.01.020 · Cited by 27 · see citing works
A Validation Study of the Fitbit One in Daily Life Using Different Time Intervals
Middelweerd, A., van der Ploeg, H. P., van Halteren, A., Twisk, J. W. R., Brug, J., & Velde, S. J. T. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001225 · Cited by 27 · see citing works
Menkin, J. A., McCreath, H. E., Song, S. Y., Carrillo, C. A., Reyes, C. E. S., Trejo, L., CHOI, S. E., Willis, P., Jimenez, E., Ma, S., et al. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.118.011088 · Cited by 26 · see citing works
Casey, M.-B., Smart, K., Segurado, R., Hearty, C., Gopal, H., Lowry, D., Flanagan, D., McCracken, L., & Doody, C. (2018) · Trials · doi:10.1186/s13063-018-2543-5 · Cited by 25 · see citing works
Validity and reliability of the Fitbit Zip as a measure of preschool children’s step count
Sharp, C., Mackintosh, K. A., Erjavec, M., Pascoe, D., & Horne, P. J. (2017) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2017-000272 · Cited by 25 · see citing works
Orstad, S. L., Gerchow, L., Patel, N., Reddy, M., Hernandez, C., Wilson, D. K., & Jay, M. R. (2021) · Informatics · doi:10.3390/informatics8020039 · Cited by 25 · see citing works
Delobelle, J., Lebuf, E., Dyck, D. V., Compernolle, S., Janek, M., Backere, F. D., & Větrovský, T. (2024) · Digital Health · doi:10.1177/20552076241262710 · Cited by 24 · see citing works
Block, V. J., Zhao, C., Hollenbach, J. A., Olgin, J. E., Marcus, G. M., Pletcher, M. J., Henry, R. G., Gelfand, J. M., & Cree, B. (2019) · Multiple Sclerosis Journal - Experimental Translational and Clinical · doi:10.1177/2055217319888660 · Cited by 24 · see citing works
Physical activity measured using wearable activity tracking devices associated with gout flares
Elmagboul, N., Coburn, B. W., Foster, J., Mudano, A. S., Melnick, J. A., Bergman, D. A., Yang, S., Chen, L., Filby, C., Mikuls, T. R., et al. (2020) · Arthritis Research & Therapy · doi:10.1186/s13075-020-02272-2 · Cited by 24 · see citing works
Ward, S., Orme, M. W., Zatloukal, J., & Singh, S. (2021) · BMC Pulmonary Medicine · doi:10.1186/s12890-021-01406-9 · Cited by 24 · see citing works
Šimůnek, A., Dygrýn, J., Gába, A., Jakubec, L., Stelzer, J., & Chmelík, F. (2016) · Acta Gymnica · doi:10.5507/ag.2016.014 · Cited by 23 · see citing works
Buis, L. R., Dawood, K., Kadri, R., Dawood, R., Richardson, C. R., Djurić, Z., Sen, A., Plegue, M. A., Hutton, D. W., Brody, A., et al. (2018) · JMIR Research Protocols · doi:10.2196/12601 · Cited by 23 · see citing works
Matz-Costa, C. J., Lubben, J., Lachman, M. E., Lee, H., & Choi, Y. J. (2018) · Journal of Gerontological Social Work · doi:10.1080/01634372.2018.1542371 · Cited by 22 · see citing works
Validation of Electronic Activity Monitor Devices During Treadmill Walking
Tam, K. M., & Cheung, S. Y. (2018) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2017.0263 · Cited by 22 · see citing works
Objective Measurement in Physical Activity Surveillance: Present Role and Future Potential
Bauman, A. E., Pedišić, Ž., & Bragg, K. (2016) · Springer series on epidemiology and public health · doi:10.1007/978-3-319-29577-0_13 · Cited by 21 · see citing works
The Role of Remote Monitoring in Evaluating Fatigue in Multiple Sclerosis: A Review
Block, V. J., Bove, R. M., & Nourbakhsh, B. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.878313 · Cited by 21 · see citing works
Sahu, K. S., Oetomo, A., & Morita, P. P. (2020) · JMIR mhealth and uhealth · doi:10.2196/21016 · Cited by 20 · see citing works
Effects of exposure to 56Fe particles on the acquisition of a conditioned place preference in rats.
Rabin, B. M., Shukitt‐Hale, B., Joseph, J. A., & Denissova, N. (2001) · PubMed · Cited by 20 · see citing works
Validation of Four Smartwatches in Energy Expenditure and Heart Rate Assessment During Exergaming
Pope, Z., Lee, J. E., Zeng, N., & Gao, Z. (2019) · Games for Health Journal · doi:10.1089/g4h.2018.0087 · Cited by 19 · see citing works
Comparing Methods to Identify Wear-Time Intervals for Physical Activity With the Fitbit Charge 2
Claudel, S. E., Tamura, K., Troendle, J. F., Andrews, M. R., Ceasar, J. N., Mitchell, V. M., Vijayakumar, N. P., & Powell‐Wiley, T. M. (2020) · Journal of Aging and Physical Activity · doi:10.1123/japa.2020-0059 · Cited by 18 · see citing works
A novel approach to the issue of physical inactivity in older age
Tiedemann, A., Hassett, L. M., & Sherrington, C. (2015) · Preventive Medicine Reports · doi:10.1016/j.pmedr.2015.07.008 · Cited by 18 · see citing works
Prieto-Centurion, V., Bracken, N. E., Norwick, L. M., Zaidi, F., Mutso, A. A., Morken, V., Coultas, D., Rand, C. S., Márquez, D. X., & Krishnan, J. A. (2016) · Chronic Obstructive Pulmonary Diseases Journal of the COPD Foundation · doi:10.15326/jcopdf.3.3.2015.0164 · Cited by 17 · see citing works
Quantifying Human Movement Using the Movn Smartphone App: Validation and Field Study
Maddison, R., Gemming, L., Monedero, J., Bolger, L. A., Belton, S., Issartel, J., Marsh, S., Direito, A., Solenhill, M., Zhao, J., et al. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.7167 · Cited by 17 · see citing works
Kim, Y., & Lochbaum, M. R. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15102268 · Cited by 17 · see citing works
Tangible Communication of Emotions with a Digital Companion for Managing Stress
Jingar, M., & Lindgren, H. (2019) · International Conference on Human-Agent Interaction (HAI) · doi:10.1145/3349537.3351907 · Cited by 17 · see citing works
Kwon, I., CHOI, S. E., Mittman, B. S., Bharmal, N. H., Liu, H., Vickrey, B. G., Song, S. Y., Araiza, D., McCreath, H. E., Seeman, T. E., et al. (2015) · BMC Neurology · doi:10.1186/s12883-015-0346-9 · Cited by 16 · see citing works
McVeigh, J. A., Ellis, J., Ross, C., Tang, K., Wan, P., Halse, R. E., Dhaliwal, S. S., Kerr, D. A., & Straker, L. M. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2020-0014 · Cited by 15 · see citing works
Keeney, J., Schneider, K. L., & Moller, A. C. (2018) · Psychology of sport and exercise · doi:10.1016/j.psychsport.2018.12.003 · Cited by 15 · see citing works
Matching science to reality: how to deploy a participant-driven digital brain health platform
Anda‐Duran, I. D., Hwang, P. H., Popp, Z., Low, S., Ding, H., Rahman, S., Igwe, A., Kolachalama, V. B., Lin, H., & Au, R. (2023) · Frontiers in Dementia · doi:10.3389/frdem.2023.1135451 · Cited by 14 · see citing works
Myers, N. D., Lee, S., Bateman, A. G., Prilleltensky, I., Clevenger, K. A., Pfeiffer, K. A., Dietz, S., Prilleltensky, O., McMahon, A., & Brincks, A. M. (2019) · Pilot and Feasibility Studies · doi:10.1186/s40814-019-0455-0 · Cited by 14 · see citing works
Validity and Reliability of the Wristband Activity Monitor in Free-living Children Aged 10-17 Years.
Yang, X., Jago, R., Zhang, Q., Wang, Y. Y., Zhang, J., & Zhao, W. H. (2019) · PubMed · doi:10.3967/bes2019.103 · Cited by 14 · see citing works
Investigating Wearable Technology for Fatigue Identification in the Workplace
Griffiths, C., Bowen, J., & Hinze, A. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-67684-5_22 · Cited by 13 · see citing works
ParaLabel: Autonomous Parameter Learning for Cross-Domain Step Counting in Wearable Sensors
Alinia, P., Fallahzadeh, R., Connolly, C. P., & Ghasemzadeh, H. G. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3009231 · Cited by 12 · see citing works
- Authors
- Tully, M. A., McBride, C., Heron, L., & Hunter, R. F.
- Affiliations
- Queen's University Belfast (GB)
- Corresponding author
- Tully, Mark A
- Venue
- BMC Research Notes
- Published
- 2014
- Volume
- 7
- Issue
- 1
- Pages
- 952
- ISSN
- 1756-0500 (ISSN-L)
- PMC
- PMC4307145
- OpenAlex
- W2102760209
- Cited by
- 172
- References
- 16
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 9 · 2023: 6 · 2022: 8 · 2021: 16 · 2020: 25 · 2019: 19 · 2018: 19 · 2017: 26 · 2016: 24 · 2015: 11
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- BMC Research Notes (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Research Portal (Queen's University Belfast) (acceptedVersion, other-oa)
- Funders
- Wellcome Trust
- United Kingdom Clinical Research Collaboration
- Alzheimer's Society
- Alzheimer's Research Trust
- Cancer Research UK
- National Institute for Health and Care Research
- British Heart Foundation
- Diabetes UK
- Stroke Association
- Public Health Agency
- Directorate for Biological Sciences
- Medical Research Council (MR/K023241/1)
- Engineering and Physical Sciences Research Council
- Economic and Social Research Council
- World Cancer Research Fund
- Health and Social Care Research and Development Division
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- wearable activity trackers, accelerometer, pedometers, free-living physical activity, step count, device validation, ActiGraph GT3X+
- MeSH terms
- Adult, Female, Humans, Male, Physical Fitness, Telemetry, Reproducibility of Results, Cohort Studies, Walking, Monitoring, Ambulatory, Young Adult, Actigraphy, Independent Living, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review