The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
SPECT/CT
Open accessAbstract
In view of the commercial success of integrated PET/CT scanners, there is an increasing interest in comparable SPECT/CT systems. SPECT in combination with CT enables a direct correlation of anatomic information and functional information, resulting in better localization and definition of scintigraphic findings. Besides anatomic referencing, the added value of CT coregistration is based on the attenuation correction capabilities of CT. The number of clinical studies is limited, but pilot studies have indicated a higher specificity and a significant reduction in indeterminate findings. The superiority of SPECT/CT over planar imaging or SPECT has been demonstrated in bone scintigraphy, somatostatin receptor scintigraphy, parathyroid scintigraphy, and adrenal gland scintigraphy. Also, rates of detection of sentinel nodes by biopsy can be increased with SPECT/CT. This review highlights recent technical developments in integrated SPECT/CT systems and summarizes the current literature on potential clinical uses and future directions for SPECT/CT in cardiac, neurologic, and oncologic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581
A Method for Attenuation Correction in Radionuclide Computed Tomography
Chang, L.-T. (1978) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1978.4329385 · Cited by 1,297
Bone Imaging in Metastatic Breast Cancer
Hamaoka, T., Madewell, J. E., Podoloff, D. A., Hortobagyi, G. N., & Ueno, N. T. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.08.181 · Cited by 656
Integrated PET/CT: Current Applications and Future Directions
von Schulthess, G. K., Steinert, H. C., & Hany, T. F. (2006) · Radiology · doi:10.1148/radiol.2382041977 · Cited by 619
Lardo, A. C., Cordeiro, M. A. S., Silva, C., Amado, L. C., George, R. T., Saliaris, A. P., Schuleri, K. H., Fernandes, V. R., Zviman, M., Nazarian, S., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.521450 · Cited by 383
Recent Advances in SPECT Imaging
Madsen, M. T. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.032680 · Cited by 338
Gould, K. L., Pan, T., Loghin, C., Johnson, N. P., Guha, A., & Sdringola, S. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.039792 · Cited by 292
Rispler, S., Keidar, Z., Ghersin, E., Roguin, A., Soil, A., Dragu, R., Litmanovich, D., Frenkel, A., Aronson, D., Engel, A., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.069 · Cited by 286
Utsunomiya, D., Shiraishi, S., Imuta, M., Tomiguchi, S., Kawanaka, K., Morishita, S., Awai, K., & Yamashita, Y. (2006) · Radiology · doi:10.1148/radiol.2373041358 · Cited by 251
Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience
Gaemperli, O., Schepis, T., Valenta, I., Husmann, L., Scheffel, H., Duerst, V., Eberli, F. R., Lüscher, T. F., Alkadhi, H., & Kaufmann, P. A. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037606 · Cited by 227
Noncardiac Findings in Cardiac Imaging With Multidetector Computed Tomography
Onuma, Y., Tanabe, K., Nakazawa, G., Aoki, J., Nakajima, H., Ibukuro, K., & Hara, K. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.071 · Cited by 215
Bocher, M., Balan, A., Krausz, Y., Shrem, Y., Lonn, A., Wilk, M., & Chisin, R. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050555 · Cited by 213
SPECT/CT hybrid imaging with 111In‐pentetreotide in assessment of neuroendocrine tumours
Krausz, Y., Keidar, Z., Kogan, I., Even‐Sapir, E., Bar‐Shalom, R., Engel, A., Rubinstein, R., Sachs, J., Bocher, M., Agranovicz, S., et al. (2003) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2003.01885.x · Cited by 192
Masood, Y., Liu, Y.-H., DePuey, G., Taillefer, R., Araujo, L. I., Allen, S., Delbeke, D., Anstett, F., Peretz, A., Zito, M.-J., et al. (2005) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2005.08.006 · Cited by 182
Gaemperli, O., Schepis, T., Kalff, V., Namdar, M., Valenta, I., Stefani, L., Desbiolles, L. M., Leschka, S., Husmann, L., Alkadhi, H., et al. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0342-9 · Cited by 151
O’Connor, M. K., & KEMP, B. J. (2006) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2006.05.005 · Cited by 149
Prideaux, A. R., Song, H., Hobbs, R. F., He, B., Frey, E. C., Ladenson, P. W., Wahl, R. L., & Sgouros, G. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.038000 · Cited by 145
Goetze, S., Brown, T. L., Lavely, W. C., Zhang, Z., & Bengel, F. M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.040535 · Cited by 143
The Impact of PET and SPECT on Dosimetry for Targeted Radionuclide Therapy
Flux, G., Bardiès, M., Monsieurs, M. A., Savolainen, S. E., Strand, S., & Laßmann, M. (2006) · Zeitschrift für Medizinische Physik · doi:10.1078/0939-3889-00291 · Cited by 132
Mahnken, A. H., Koos, R., Katoh, M., Spuentrup, E., Busch, P., Wildberger, J. E., K�hl, H. P., & Günther, R. W. (2005) · European Radiology · doi:10.1007/s00330-004-2592-x · Cited by 132
Fourier correction for spatially variant collimator blurring in SPECT
Xia, W., Lewitt, R. M., & Edholm, P. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370406 · Cited by 116
Frank, A. R., Lefkowitz, D. M., Jaeger, S. S., Gobar, L. S., Sunderland, J. J., Gupta, N. C., Scott, W. J., Mailliard, J. A., Lynch, H. T., Bishop, J. W., et al. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(94)00622-r · Cited by 108
ROACH, P. J., Schembri, G. P., Shon, I. A. H., et al. (2006) · Nuclear Medicine Communications · doi:10.1097/01.mnm.0000243372.26507.e7 · Cited by 105
Dual-Modality Imaging of Cancer with SPECT/CT
Hasegawa, B. H., Wong, K. H., Iwata, K., Barber, W. C., Hwang, A. B., Sakdinawat, A. E., Ramaswamy, M. R., Price, D. C., & Hawkins, R. A. (2002) · Technology in Cancer Research & Treatment · doi:10.1177/153303460200100605 · Cited by 97
Economic and biological costs of cardiac imaging
Picano, E. (2005) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-3-13 · Cited by 96
Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT
McQuaid, S. J., & Hutton, B. F. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0718-0 · Cited by 91
Berman, D. S., Shaw, L. J., Hachamovitch, R., Friedman, J. D., Polk, D. M., Hayes, S. W., Thomson, L., Germano, G., Wong, N. D., Kang, X., et al. (2006) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2006.08.002 · Cited by 77
Hillel, P. G., van Beek, E. J. R., Taylor, C., et al. (2006) · Clinical Radiology · doi:10.1016/j.crad.2006.04.001 · Cited by 72
Avram, A. M., Fig, L. M., & Gross, M. D. (2006) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2006.03.004 · Cited by 66
Storto, G., Cirillo, P. L., Vicario, M. L. E., Pellegrino, T., Sorrentino, A. R., Petretta, M., Galasso, G., Sanctis, V. D., Piscione, F., & Cuocolo, A. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2004.08.007 · Cited by 59
Gabriel, M., Hausler, F., Bale, R. J., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1875-z · Cited by 59
Cremonesi, M., Ferrari, M. E., Grana, C. M., Vanazzi, A., Stabin, M., Bartolomei, M., Papi, S., Prisco, G., Martinelli, G., Paganelli, G., et al. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044016 · Cited by 55
Bouček, J., & Turner, J. H. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1692-9 · Cited by 52
Chen, J., Caputlu-Wilson, S. F., Shi, H., Galt, J. R., Faber, T. L., & Garcia, E. V. (2006) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2005.11.007 · Cited by 45
Endocrine Neoplasm Scintigraphy
Ingui, C. J., Shah, N. P., & Oates, M. E. (2006) · Clinical Nuclear Medicine · doi:10.1097/01.rlu.0000242599.22310.d2 · Cited by 43
Contemporary adrenal scintigraphy
Gross, M. D., Avram, A. M., Fig, L. M., & Rubello, D. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0265-5 · Cited by 34
Henneman, M. M., Schuijf, J. D., Dibbets‐Schneider, P., Stokkel, M. P. M., van der Geest, R. J., van der Wall, E. E., & Bax, J. J. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.07.084 · Cited by 34
Patient dosimetry in radionuclide therapy: the whys and the wherefores
Thierens, H. M., Monsieurs, M. A., & Bacher, K. (2005) · Nuclear Medicine Communications · doi:10.1097/01.mnm.0000167910.76718.ad · Cited by 34
Schietinger, B. J., Bozlar, U., Hagspiel, K. D., Norton, P. T., Greenbaum, H. R., Wang, H., Isbell, D. C., Patel, R. A. G., Ferguson, J., Gay, S. B., et al. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.10.008 · Cited by 32
Ballok, Z. E. (2005) · Heart Lung and Circulation · doi:10.1016/j.hlc.2005.08.012 · Cited by 5
Cited by
Pansare, V. J., Hejazi, S., Faenza, W. J., & Prud’homme, R. K. (2012) · Chemistry of Materials · doi:10.1021/cm2028367 · Cited by 706
A review on the clinical uses of SPECT/CT
Mariani, G., Bruselli, L., Kuwert, T., Kim, E. E., Flotats, A., Israel, O., Dondi, M., & Watanabe, N. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1390-8 · Cited by 438
Dewaraja, Y. K., Frey, E. C., Sgouros, G., Brill, A. B., Roberson, P., Zanzonico, P. B., & Ljungberg, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.100123 · Cited by 419
Targeting Cardiovascular Implant Infection: Multimodality and Molecular Imaging
Sohns, J. M., Bavendiek, U., Ross, T. L., & Bengel, F. M. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.005376 · Cited by 24
Metadata
- Authors
- Buck, A. K., Nekolla, S., Ziegler, S., Beer, A., Krause, B. J., Herrmann, K., Scheidhauer, K., Wester, H.-J., Rummeny, E. J., Schwaiger, M., & Drzezga, A.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-07-16
- Volume
- 49
- Issue
- 8
- Pages
- 1305-1319
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W4249150730
- Cited by
- 282
- References
- 40
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.