Reproducibility of Standardized Uptake Value Measurements Determined by 18F-FDG PET in Malignant Tumors
Open accessAbstract
Abstract ‘Cuttlebone’, the internalized shell found in all members of the cephalopod family Sepiidae, is a sophisticated buoyancy device combining high porosity with considerable strength. Using a complementary suite of characterization tools, we identified significant structural, chemical and mechanical variations across the different structural units of the cuttlebone: the dorsal shield consists of two stiff and hard layers with prismatic mineral organization which encapsulate a more ductile and compliant layer with a lamellar structure, enriched with organic matter. A similar organization is found in the lamellar matrix, which consists of individual chambers separated by septa, and supported by meandering plates (‘pillars’). Like the dorsal shield, septa contain two layers with lamellar and prismatic organization, respectively, which differ significantly in their mechanical properties: layers with prismatic organization are a factor of three stiffer, and up to a factor of ten harder than those with lamellar organization. The combination of stiff and hard, and compliant and ductile components may serve to reduce the risk of catastrophic failure, and reflect the role of organic matter for the growth process of the cuttlebone. Mechanically ‘weaker’ units may function as sacrificial structures, ensuring a step-wise failure of the individual chambers in cases of overloading, allowing the animals to retain near-neutral buoyancy even with partially damaged cuttlebones. Our findings have implications for the structure-property-function relationship of cuttlebone, and may help to identify novel bioinspired design strategies for light-weight yet high-strength foams.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
“Concordantly, Nahmias and Wahl (115) showed in test–retest studies that absolute differences in mean SUV obtained from a large ROI did not exceed 0.5 SUV unit and that the absolute differences in mean SUV decreased as mean SUV increased.”
BackgroundMethodInfluentialA Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662
Kinahan, P. E., & Fletcher, J. W. (2010) · Seminars in Ultrasound, CT and MRI · doi:10.1053/j.sult.2010.10.001 · Cited by 631
Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
Repeatability of SUV in Oncologic 18F-FDG PET
Lodge, M. A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.186353 · Cited by 214
Impact of the Definition of Peak Standardized Uptake Value on Quantification of Treatment Response
Vanderhoek, M., Perlman, S. B., & Jeraj, R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.093443 · Cited by 188
Repeatability of 18F-FDG Uptake Measurements in Tumors: A Metaanalysis
de Langen, A. J., Vincent, A., Velasquez, L. M., van Tinteren, H., Boellaard, R., Shankar, L. K., Boers, M., Smit, E. F., Stroobants, S., Weber, W. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.095299 · Cited by 157
“(21)), no difference in test–retest variability was apparent between the studies (P 5 0.”
BackgroundMethodResultInfluentialSher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0177-8 · Cited by 111
“Because this VOI encompasses several pixels, SUVpeak is assumed to be less affected by image noise than SUVmax [4, 5] and then more reliable and * Correspondence: av.”
BackgroundHeusch, P., Buchbender, C., Beiderwellen, K., Nensa, F., Hartung-Knemeyer, V., Lauenstein, T. C., Bockisch, A., Forsting, M., Antoch, G., & Heusner, T. A. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.01.008 · Cited by 96
Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT
Doot, R. K., Scheuermann, J. S., Christian, P. E., Karp, J. S., & Kinahan, P. E. (2010) · Medical Physics · doi:10.1118/1.3499298 · Cited by 82
Variance of SUVs for FDG-PET/CT is Greater in Clinical Practice Than Under Ideal Study Settings
Kumar, V., Nath, K., Berman, C. G., Kim, J., Tanvetyanon, T., Chiappori, A. A., Gatenby, R. A., Gillies, R. J., & Eikman, E. A. (2013) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318279ffdf · Cited by 76
“Deviation from targeted uptake times is a well-known cause of variation in avidity.(18,20,34) FDG uptake in lung carcinoma, for example, does not plateau for several hours,(31,35,36) so variation in uptake period should cause variation in SUV.”
BackgroundFDG PET/CT-based response assessment in malignancies
Parihar, A. S., Dehdashti, F., & Wahl, R. L. (2023) · RadioGraphics · doi:10.1148/rg.220122 · Cited by 53
“Measurement of the SUV (typically, the maximum SUV [SUV max ]) in a standardized and consistent imaging environment serves as a reproducible parameter that can be assessed and compared between baseline and posttreatment imaging in addition to the visual interpretation (28).”
Vanderhoek, M., Perlman, S. B., & Jeraj, R. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.113332 · Cited by 47
Mittal, B., Kuruva, M., Abrar, M., Kashyap, R., & Bhattacharya, A. (2012) · Indian Journal of Nuclear Medicine · doi:10.4103/0972-3919.108835 · Cited by 24
Fledelius, J., Khalil, A., Hjorthaug, K., & Frøkiær, J. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0223-6 · Cited by 24
Two-Time-Point FDG PET/CT: Liver SULmean Repeatability
Tahari, A. K., Paidpally, V., Chirindel, A., Wahl, R. L., & Subramaniam, R. M. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.12719 · Cited by 10
Metadata
- Authors
- Nahmias, C., & Wahl, L. M.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-10-16
- Volume
- 49
- Issue
- 11
- Pages
- 1804-1808
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2125161228
- Cited by
- 200
- References
- 1
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.